• Title/Summary/Keyword: SCOD

Search Result 177, Processing Time 0.031 seconds

An Experimental Study on the Treatment of Phenolic Wastewater Using Rotating Biological Contactors (회전원판법(RBC)에 의한 페놀성 폐수의 처리에 관한 실험적 연구)

  • Choung, You Kyoo;Ahn, Kyu Hong;Bae, Bum Han;Min, Byeong Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.173-184
    • /
    • 1990
  • This study is an experimental research on the treatment of phenolic wastes by Rotating Biological Contactors(RBC). The objective of this study is to determine the optimum range of influent phenol concentration and organic loading rate. Organic removal rates were analyzed with increasing organic loading and influent phenol concentration, together with the observation of microorganism. Biomass, SCOD, and phenol concentration were measured under the steady state after a step change of influent phenol concentration. As the result, at the phenol concentration less then 98.8 mg/L there were no evidence of substrate inhibition. As the results, organic removal rates in each stage at various organic loading, were decreased with increasing phenol concentration. First order kinetic was observed on the removal of SCOD for which phenol concentration is within the range of substrate inhibition. And also, microorganisms were changed with influent phenol concentration. Namely, at low influent phenol concentration, thin biofilm with filamentous growth was produced. To the contrary, thick biofilm with nonfilamentous growth was produced at high influent phenol concentration.

  • PDF

Optimal Conditions for Improving Enzyme Preteatment Efficiency in Sludge Reduction Process. (슬러지 저감시 효소 전처리의 효율 향상 및 최적화 연구)

  • 김정래;심상준
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.2
    • /
    • pp.166-171
    • /
    • 2004
  • In this study, we introduced enzymatic pretreatment method, together with ozone treatment for sludge digestion. We optimized the amount of enzyme and ozone, respectively for the successful sludge pretreatment. As a result, we found that as more enzyme is used, higher sludge hydrolysis efficiency was obtained. When we treated sludge by ozone ranging from 0.01g $O_3$/g SS to 0.04 g $O_3$/g SS without enzyme treatment, 0.04 g $O_3$/g SS showed the highest increase of SCOD. Meanwhile, when protease was used together with the same ozone dosage ranges, 0.03g $O_3$/g SS ozonation resulted in the highest increase of SCOD. The sludge pretreatment was optimized by controlling the amount of enzyme and ozone.

Optimization and kinetic modeling for bioconversion of cheese whey to Ganoderma lucidum in batch fermentations

  • Song, Min-Gyeong;Lee, Hwan-Yeong;Hwang, Seok-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.381-384
    • /
    • 2002
  • Response surface methodology (RSM) was successfully applied to optimize for the production of Ganoderma lucidum in batch fermentations using the whey (40,000 mg latose/L) as substrate. This study was performed according to the central composite design (CCD) with respect to pH and temperature, where the designed intervals were 3.3$22.9^{\circ}C$$37.1^{\circ}C$, respectively. A second-order factorial design of the experiments was used to build empirical models providing a quantitative interpretation of the relationships between the two variables. The optimum conditions to maximize the production of G. lucidum were pH 4.2 and $28.3^{\circ}C$. At optimum conditions, the mycelial dry weight (MDW) and residual soluble COD (SCOD) were simultaneously used to evaluate the biokinetic coefficients assocoated with substrate inhibition model by nonlinear least squares method with 95% confidence interval. The. maximum microbial growth rates (${\mu}m$), half saturation coefficient ($K_s$), and the inhibition substrate concentration ($K_{is}$) were determined to be 0.095 l/hr, 128,000 mg SCOD/L and 49,000 mg SCOD/L, respectively. And the microbial yield coefficient (Y), biomass decay rate coefficient ($K_d$), and the maintenance energy coefficient ($m_s$) were determined to be 0.37 mg MDW/mg SCOD, 0.001 1/hr, and 0.0015 1/hr, respectively.

  • PDF

The Study on the Solubilization of Sewage Sludge by Electrolysis Treatment (전기분해를 이용한 하수슬러지 가용화 연구)

  • Kim, Jae Hyung;Jeon, Hye Yeon;Lee, Jun Cheol;Pak, Dae Won
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • In this research, a sewage sludge solubilization study using electrolysis was performed as a pre-treatment for anaerobic digestion efficiency improvement. SCOD potency increased as the treatment time and electric current density increased with sludge electrolysis treatment while SCOD, TN, and TP especially showed the highest increase of 7.4 times, 1.9 times, and 1.3 times respectively at the 60 minute point of treatment. Solubilization was high at the strong acidic and alkaline status for the sewage sludge electrolysis treatment results along early stage pH, and especially, a high solubilization percentage of 32.9% was seen at pH 12. The above result shows that there was an increase of organic matter able to be used by microorganisms from sludge floc and the destruction of EPS structure due to direct and indirect oxidation following electrolysis.

The Nutrient Removal of Mixed Wastewater composed of Sewage and Stable Wastewater using SBR (SBR을 이용한 하수와 우사폐수로 구성된 혼합폐수의 영양소 제거)

  • 김홍태
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.617-623
    • /
    • 1999
  • This study was carried out to obtain the optimal operating parameter on organic matters and nutrient removal of mixed wastewater which was composed of sewage and stable wastewater using SBR. A laboratory scale SBR was operated with An/Ae(Anaerobic/Aerobic) ratio of 3/3, 2/4 and 4/2(3.5/2.5) at organic loading rate of 0.14 to 0.27 kgBOD/$m^3$/d. TCOD/SCOD ratio of mixed wastewater was 3, so the important operating factor depended upon the resolving the particulate parts of wastewater. Conclusions of this study were as follows: 1) For mixed wastewater, BOD and COD removal efficiencies were 93-96% and 85-89%, respectively. It was not related to each organic loading rate, whereas depended on An/Ae ratio. During Anarobic period, the amount of SCOD consumption was very little, because ICOD in influent was converted to SCOD by hydrolysis of insoluble matter. 2) T-N removal efficiencies of mixed wastewater were 55-62% for Exp. 1, 66-76% for Exp. 2, and 67-81% for Exp. 3, respectively. It was found that nitrification rate was increased according to organic concentration in influent increased. Therefore, the nitrification rate seemed to be achieved by heterotrophs. During anoxic period, denitrification rate depended on SCOD concentration in aerobic period and thus, was not resulted by endogenous denitrification. However, the amount of denitrification during anaerobic period were 3.5-14.1 mg/cycle, and that of BOD consumed were 10-40 mg/cycle. 3) For P removal of mixed wastewater, EBPR appeared only Mode 3($3^*$). It was found that the time in which ICOD was converted to VFA should be sufficient. For mode 3 in each Exp., P removal efficiencies were 74, 87, and 81%, respectively. But for 45-48 of COD/TP ratio in influent, P concentration in effluent was over 1 mg/L. It was caused to a large amount of ICOD in influent. However, as P concnetration in influent was increased, the amounts of P release and uptake were increased linearly.

  • PDF

Sludge reduction by Enzyme Pretreatment (효소 전처리를 통한 슬러지 저감)

  • 김정래;심상준;최수형;염익태
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.93-97
    • /
    • 2004
  • We investigate the effect of enzyme pretreatment using protease, carbohydrase, and lipase on improvement of sludge treatment efficiency by measuring SCOD and TCOD. The enzyme-pretreatment increases SCOD of excess sludge. In addition, the amount of sludge reduction during digestion, in terms of SCOD and TCOD, are enhanced by enzyme-pretreatment. Among pretense, carbohydrase, and lipase, pretense showed the best enhancement of the sludge treatment efficiency. Sludge digestion followed by ozone and enzyme treatments showed more effective sludge treatment when compared with ozone treatment alone. Therefore, we expect that enzyme pretreatment can be used as a useful tool for enhancing the sludge treatment efficiency.

Effect of pH on the $VFA_s$ fermentation in the anaerobic treatment of food waste (pH조절이 음식폐기물의 유기산발효에 미치는 영향)

  • 조한진;성낙창;김은호;장성호;손영일;박진식
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.32-37
    • /
    • 2001
  • The purpose of this study was to investigate the created liquid post-acid fermentation of usability of denitrification as exterior carbon sources by pH control. The time of acid fermentation of food waste, the slower loading capacity of organic matter, the faster decomposition rate, but the density of generation Volatile Fermentation Acids(VFAs), was weak and, $SBOD_{5}$ : ST-N rate and $SBOD_{5}/SCOD_{Cr}$ rate was low. Between TS and VS, VS was decreased to 4.5th day fast, and then was decreased slowly. 1.5 days after stating the experiments, $SCOD_{Cr}$, $SBOD_{5}$, STOC and $VFA_{s}$ was decreased of increased slowly, and then increased fast. And after showing the highest density, it was tended to decreased fast. At the time of $SBOD_{5}$ with the highest density, at $SBOD_{5}$ : ST-N ratio, $R_1$ was 303:1, $R_2$ was 319:1, $R_3$was the highest. After studying $SBOD_{5}$ : ST-N ratio and $SBOD_{5}/SCOD_{Cr}$ ratio, as a carbon source of biological denitrification it was profitable composition ratio.

  • PDF

Sludge Reduction in Activated Sludge Process by solubilizing Return Sludge using Electric Field/Ultrasonification (전기장 및 초음파에 의한 반송슬러지의 가용화에 따른 활성슬러지에서의 슬러지 감량화)

  • Yoon, Soon-Uk;Ahn, Chang-Min;Kim, Chang-Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.329-336
    • /
    • 2013
  • This study was conducted to reduce excess sludge generation by recycling of return sludge to the aeration tank after solubilization by electric field charger and ultrasonifier. The return sludge was purposely broken-up to the ratio of $SCOD_{Cr}/TCOD_{Cr}$ at 0.1, 0.2, and 0.3, which was tested along with control (i.e., untreated). Solubilized sludge was subsequently treated in a bench-scaled conventional activated sludge reactor. According to varying $SCOD_{Cr}/TCOD_{Cr}$ ratios, TSS in the reactor was correspondingly increased from 129 to 219 mg/L and $TCOD_{Cr}$ was also from 257 to 335 mg/L. However, TSS in the effluent was nevertheless kept lower at below 30 mg/L and $TCOD_{Cr}$ was also unvaryingly below 40 mg/L. For $SCOD_{Cr}/TCOD_{Cr}$ = 0.3, the amount of excess sludge produced was at the highest decreased up to as high as 78%.

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

A Study on the Correlation of Organic Factors in Municipal Waste Water (도시하수중 유기인자의 상호기관에 관한 연구)

  • 황상용;손종열;우완기
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.55-61
    • /
    • 1990
  • Laboratory methods commonly used today are biochemical oxygen demand, chemical oxygen demand, and total organic carbon. Establishment of constant relationships among the various measures of organic content depends primarily on the nature of the wastewater and its source. Of all the measures, the most difficult to correlate to the others is the BODs test, because of the problems associated with biological tests. The results were summarized as follwos, 1. For typical municipal wastes, however, the SBOD$_{5}$/SCOD$_{cr}$ ratio varies from 0.14 to 0.34(mean 0.21), SBOD$_{5}$/STOC ratio varies from 0.35 to 1.19(mean 0.69) 2. Correlation analysis between the SBOD$_{5}$ and SCOD$_{cr}$ gave good correlation coefficient r = 0.903 and the equation Y = 3.756X + 16,221 was obtained. 3. The correlation between the SBOD$_{5}$ and STOC was well presented with equation : Y = 1,070X + 7,637, and also correlation coefficient r = 0.821 4. The correlation between the SCOD$_{cr}$ and STOC was well presented with equation : Y = 0.256X +5.513 and also correlation coefficient r = 0.816. 5. Because of the rapidity with which the TOC test can be conducted, it is anticipated that more use will be made of these tests in the future.

  • PDF