• Title/Summary/Keyword: SCADA Monitoring

Search Result 67, Processing Time 0.028 seconds

Development of open MMI system for integration of business computers and process computers (포항제철소 B/C-P/C 통합을 위한 개방형 MMI 개발)

  • 추영열;김경백;황화원;김영일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.684-687
    • /
    • 1997
  • In order to access to the Business Computer (B/C), the Process Computer(P/C), and the Database Server in one terminal, the Open Man Machine Interface (MMI) System has been developed. The testbed to develop the interface functions for B/C, P/C, DB server, and CCD camera were constructed, which consisted of Workstations and Personal Computers (PC). Graphic display programs Monitoring the process states of Tandem Cold Mill plant were developed using four Graphic User Interface tools: InTouch, FIX32, Open Interface Environment, and ILOG Views. With regard to the CPU utilization and response delay required to open new display, the performance tests have been carried out on each MMI platform.

  • PDF

Cold electronics based 128 temperature sensor interface with 14 leads for testing of high Tc superconducting cable

  • Gour, Abhay Singh;Thadela, S.;Rao, V.V.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.1
    • /
    • pp.11-14
    • /
    • 2018
  • High Temperature Superconducting (HTS) power cables are capable of transmitting bulk power without any loss compared to conventional copper cables. The major challenge in the design of such HTS cables is the high stresses (electro-thermal/electro-mechanical) developed at high voltages, high currents and cryogenic temperatures. The safe and reliable operation of HTS cables involves lots of instrumentation for monitoring, measurement, control and safe operation. In principle, a four probe method for resistance (RTD PT-100) is used for temperature measurements at various locations of HTS cable. The number of connecting leads required for this is four times that of the number of sensors. The present paper discusses a novel way of connecting 128 RTD sensors with the help of only 14 leads using a cold electronics based multiplexer board. LabVIEW 11.0 software was used for interfacing and displaying the readings of all the sensors on computer screen.

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.

Development of DPA(DNP3.0 Protocol Analyzer) Platform (DPA(DNP3.0 Protocol Analyzer) 플랫폼 개발)

  • Song, Byeong-Kwon;Lee, Sang-Hun;Jeong, Tae-Eui;Kim, Gun-Woong;Kim, Jin-Cheol;Kim, Young-Eok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.480-484
    • /
    • 2008
  • DNP3.0은 산업 분야에서 SCADA(Supervisory Control And Data Aquisition) system의 개방형 프로토콜로 사용되어지고 있다. 본 논문에서는 개발하거나 개발된 Module들 사이에서 송 수신되는 DNP3.0 PDU를 분석할 수 있는 기능을 제공하는 DPA(DNP3.0 Protocol Analyzer) Module을 설계 및 구현하였다. 해당 Master Station에서 Request 메시지를 생성하여 Outstation으로 전송하고 Outstation에서 수신된 Request 메시지를 분석하여 Response 메시지를 생성하여 Response 한다. 또한 Master Station 과 Outstation에서 DNP3.0 프로토콜을 사용하여 통신하는 중간에서 송 수신하는 메시지를 Monitoring한다.

  • PDF

The Study of the Automation Systems using Satellite Communications (위성통신을 이용한 자동화 감시 시스템 구축 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2540-2542
    • /
    • 2002
  • In recent years, it is a worldwide trend that many power utilities focus their attention to employ up-to-date communication technology to the automation of their power plants and distribution systems. Automation Systems in Korea was installed using twisted pair cable(TPC), power line carrier(PLC), coaxial cable(CA), wireless network(wireless data, TRS and PCS). Among the communication media only Satellite Communication guarantees the reliable communication in case of emergency such as a flood, a heavy snow and an earthquake. It can integrate two-way satellite systems to existent nationwide SCADA controlling points of electric power transmission & distribution system that enables real time remote monitoring and controlling automatically. This paper presents some of design efforts for the satellite communication network as the media of Automation Systems.

  • PDF

The Development of Multi-Function Measurement Module for RTD and 4-20[mA] Analog Input (RTD와 4-20[mA] 아날로그 계측용 다기능 모듈의 개발)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper, multi-functional measurement module for RTD and 4-20mA Analog input is presented. As you know, In many industry field, RTD has been used for measuring a temperature. Although It have good properties such as wide measurement range, accuracy, the hardware or software compensation methods were applied to better linearity in many applications. According to this paper, a simply approximation method and various measuring technique are proposed to compensate large lead's resistance influence in RTD temperature measurements. As the experiment and simulation results, it is proved that the proposed method has good performance of measuring temperature. Additionally, with the CAN based communication, remote monitoring and parameter setting functions are realized.

Historical Data, Transaction and Database for Industrial Monitoring and Control Applications (산업감시 및 제어 응용을 위한 이력 데이터, 트랜잭션 그리고 데이터베이스)

  • Han, Sang-Hyuck;Kim, Young-Kuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.1051-1053
    • /
    • 2012
  • SCADA, DCS, PLC 등 산업제어시스템은 전기, 수도, 수송, 가스 및 석유와 같은 국가기반시설의 감시 및 제어를 통해 위험의 조기 예측, 대응, 각 공정의 품질 향상 등에 기여하고 있다. 산업제어시스템은 HMI(Human Machine Interface), 이력 데이터베이스, 각 센서 H/W 및 S/W 기술로 구성되는데, 그 중 이력 데이터베이스는 실시간으로 들어오는 디지털 및 아날로그 형태의 이력 데이터에 대한 효과적으로 처리하기 위한 주요 요소이다. 현재, 국내에서는 히스토리안 등 주로 외산 제품에 의존하고 있어 이에 대한 기반 기술 연구 및 관련 산업화가 요구된다. 또한, 이력 데이터베이스의 종류 및 특성에 대한 연구가 선행되어야 한다. 본 논문에서는 산업제어시스템에 주로 적용된 이력 데이터베이스들에 대해 자세히 살펴보고, 일반적으로 사용되는 데이터와 산업제어시스템에서 사용하는 이력 데이터와 트랜잭션의 특징을 살펴봄으로써 산업제어 응용에서 요구되는 이력 데이터베이스가 어떤 모습을 갖추어야 할 지에 대한 이해를 높이고자 한다.

Research on key management for supervisory control and data acquisition system (원격 감시 제어시스템에서 키 관리 방안 연구)

  • Lee, Keonjik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.4
    • /
    • pp.29-42
    • /
    • 2020
  • SCADA (Supervisory Control and Data Acquisition) systems for remote monitoring, data acquisition and control are applied to major industrial infrastructures including power, water and railroad. Recently, there are many researches on key management scheme for secure communication due to change to the open network environment. These systems are located at far distances and are connected to the main control center through various types of communication methods. Due to the nature of these systems, they are becoming the significant targets of cyber attack. We propose an efficient key management scheme which is established on ID-based cryptosystem without an expensive computation on MTU (Master Terminal Unit), Sub-MTU, and RTU (Remote Terminal Unit). The proposed method is secure and effective in key management among multiple legitimate devices.

DNP3.0 Traffic Monitoring System (DNP3.0 트래픽 모니터링 시스템)

  • Song, Byung-Kwon;Kim, Sei-Byuck;Jeong, Tae-Eui;Kim, Kun-Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.845-848
    • /
    • 2008
  • DNP3.0(Distributed Network Protocol 3.0) 프로토콜은 자동화 처리 시스템 사이에서 Master와 Slave의 개념을 적용한 프로토콜로써 현재 한전 SCADA 시스템의 표준 프로토콜로 선정되어 원방 감시 제어용으로 사용되고 있다. 이 DNP3.0 데이터를 RS-232C를 이용해서 전송 할 때, 각각의 DNP3.0 Layer인 DataLink Layer, Transport Layer 그리고 Application Layer의 분석 모듈을 설계하고 구현하였다.

Monitoring system design&Implementation using wireless solution (무선 통신을 사용한 모니터링 시스템의 설계 및 구현)

  • Jeon Yoon-Ho;Woo Jong-Hyun;Kim Young-Ryun;Kim Hee-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • RS-232C는 정보기기들을 연결하는 직렬통신 표준으로, 간단한 구조로 인해, 복잡한 요구 조건이 없는 상용 기기들의 제어 및 감시용으로 사용되고 있다. 최근 무선동신기술이 발전함에 따라, 저가격의 무선통신 기술을 활용하여 무선 RS-232C에 대한 요구가 늘어나고 있다. 무선 RS-232C로 기존 유선의 RS-232C를 대체함으로서, 기존 시스템의 변경없이 편리한 접속기능을 대체한 수 있을 것이다. 본 논문에서는 유선 RS-232C를 대체하는 무선 RS-232C 모듈을 채용하여, 전력제어에 사용하는 배전자동화 장치의 관리를 간편하게 하는 시스템의 구현에 대해서 다루고 있다. 배전 자동화시스템은 일종의 SCADA시스템의 일부로서, 통신 프로토콜로서 산업용 DNP3.0을 사용하고 있다. 무선 RS-232C 링크의 신뢰성을 확보하기 위하여, 무선 구간에 DNP3.0을 채택하였으며, 무선 통신방식으로는 무선 RF, 블루투스(Bluetooth), 무선랜(wireless LAN)등 3가지 방식을 채용하여, 설계, 구현내용을 기술하였다.

  • PDF