• Title/Summary/Keyword: SBR 공법

Search Result 24, Processing Time 0.025 seconds

Estimation of Nutrient Removal Efficiency and Phase Conversion Rate of Single Reactor SBR and SBR with Flexible Vertical (단일 및 가변형 SBR 공법의 영양염류 처리효율 및 "상"전환속도 평가)

  • Kim, Man-Soo;Park, Jong-Woon;Park, Chul-Whi;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1215-1221
    • /
    • 2005
  • The purpose of this research was to compare the nutrient removal efficiency, and to estimate the net reaction time in order to calculate a "phase" transfer rate. SBR(SBR1) with flexible verticals and single reactor SBR(SBR1). Consequently, the removal efficiencies of $COD_{Cr}$, and $BOD_5$ in SBR1 and SBR2 were 91.5%, 97.5% and 90.4%, 97.3%, Respectively. Accordingly, the organic removal efficiency was not distinguished in both processes. In the T-N and T-P removal efficiencies, however, SBR1 obtained higher removal efficiency than SBR2, at 12.1% and 7.6% respectively. Also, in the experiment to estimate the "phase" transfer rate, SBR1 was higher than SBR2 Because SBR1 has two phases in the single reactor simultaneously, it has the buffer capacity to reduce the "phase" transfer time and provides a definite reaction condition.

Advanced Wastewater Treatment Status of Sewage Treatment Plants and Improvement Methods (하수종말처리시설 고도처리현황 및 개선방안)

  • Moon, Sun-Jung;Choi, Pill-Gyu;Choi, Ick-Hoon;Park, Jae-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1174-1178
    • /
    • 2007
  • 본 연구는 다양한 공법으로 설치 운영되고 있는 고도처리시설에 대한 처리효율 및 운영현황을 조사하여 고도처리공법 선정시 활용할 수 있는 기초자료를 제공하고, 각 공법별 현장적용 및 운영상 문제점을 파악하여 하수처리시설 운영의 효율성을 도모하기 위한 목적으로 실시하였다. 6개월 이상 운영 중인 하수종말처리시설 145개소를 대상으로 일반적 현황을 분석하고 실제 현장조사는 고도처리시설 37개소의 현장조사표를 중심으로 실시하였다. 고도처리 공법은 $A_2O$계열, SBR계열이 대부분을 차지하였으며 대규모처리장은 $A_2O$계열, 소규모처리장은 SBR계열이 주로 적용되었으며 대규모 하수처리시설일수록 유입수질의 농도 및 처리효율이 높고 톤당 시설설치비용과 유지관리비용이 적었다. 현장조사 결과, 첫째, 하수처리시설의 유입문제로 시설용량대비 하수유입량이 초과되거나 50%미만인 시설이 10개소로 조사되었다. 이에 따라 하수관거의 조속한 정비 및 인구감소에 따른 대책수립, 효율적인 운영을 위한 하수처리시설 증설 및 계열 축소운전이 필요하였다. 둘째, 각 처리공법별로 몇몇 문제점이 있어 공법사의 문제점 보완, 운영기술전수 및 원활한 A/S가 필요한 것으로 나타났다. 셋째, 운영관리자가 수시로 현상을 파악하고 주의하여 운전해야 하는 것으로 나타났다.

  • PDF

Analysis of RCSTP Treatment Efficiency using BCS-II Process: Case Study of An-dong City (BCS-II 공법을 이용한 마을하수도 처리 효율 분석: 안동시를 대상으로)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.423-431
    • /
    • 2014
  • Supply of rural community sewage treatment plant (RCSTP) is need for protect of water quality like water source and development of agriculture areas. In this study conducted analysis on characteristics of RCSTP sewage and treatment efficiency of installed treatment process using operation results of RCSTP in an-dong area. high organic matter and nutrient were contained in RCSTP sewage of an-dong than urban area. RCSTP treatment process in an-dong was shown stable treatment efficiency. But nutrient treatment efficiency was shown more sensitive result about SRT and F/M ratio than organic matter treatment efficiency. And RCSTP treatment process in an-dong was shown higher treatment efficiency than other treatment proces like $A^2/O$, SBR and media. Thus, this process is effective treatment process for application of RCSTP.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

Shipboard sewage treatment by Sequence Batch Reactor utilizing Beneficial Microorganisms (유용미생물을 적용한 선박오수용 SBR공정에 관한 연구)

  • Kim, In-Soo;Lee, Eon-Sung;Ha, Shin-Young;Oh, Yeom-Jae;Ekpeghere, Kelvin I.;Koh, Sung-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.10a
    • /
    • pp.36-37
    • /
    • 2010
  • Lab scale experiment was carried out to study applicability of BM (Beneficial Microorganisms) to the conventional SBR system for the shipboard sewage treatment. BM has been successfully applied to the wastewater treatment by the SBR process and hence this system maintained a stable effluent quality together with an increased treatment efficiency, meeting the requirements of IMO regulations. The SBR system facilitated by BM would be a suitable process for cruise ships in terms of the malodor control, treatment efficiency and operation conveniences.

  • PDF

Shipboard sewage treatment using Sequence Batch Reactor (SBR을 이용한 선박오수 고도처리장치 개발)

  • Kim, In-Soo;Oh, Yeom-Jae;Lee, Eon-Sung
    • Journal of Navigation and Port Research
    • /
    • v.34 no.5
    • /
    • pp.375-381
    • /
    • 2010
  • This study was carried out for advanced treatment development on shipboard sewage. We employed SBR process using Bacillus sp. to remove Organic compounds, Nitrogen and Phosphorus simultaneously. Based on Res. MEPC.159(55) the system was qualified. From the results it was suggested that SBR system might be suitable process for shipboard sewage treatment in terms of pollutant removal efficiency, maintenance and special environmental conditions of ship. More than 90% of COD and BOD were removed. In addition, aover 50% of T-N and T-P were reduced.

Characteristics of Nutrient Removal with Variation of the Anoxic-Oxic Phase Repetition in Sequencing Batch Reactor Process (SBR공정의 무산소-호기 구간반복에 따른 영양염류 제거 특성)

  • Lee, Jaekune;Yim, Soobin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • This study was performed to investigate the characteristics of nutrient removal by Sequencing Batch Reactor (SBR) system, which could achieve high removal efficiencies of nitrogen and phosphorus and make it possible convenient management and operation. In this study, dissolved oxygen (DO), chemical oxygen demand (COD), nitrogen, and phosphorus in SBR system were examined by variation of anoxic-oxic phase repetition in order to optimize an operational method. The 1~4 times of anoxic-oxic phases (Run 1~4) were repeated during 1 cycle operation period. As the repetition frequency increased, it was more difficult to maintain DO condition enough for denitrification. The SBR system showed high COD removal efficiency more than 91% regardless of operational condition. About 68% of nitrogen removal rate was obtained in conditions of 2 or 3 times repetition of anoxic phases, in which NOx-N among discharged total nitrogen account for more than 99%. Approximately 40% of phosphorus was eliminated in the conditions of 1~3 times of anoxic phase repetition.

  • PDF

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).

Bio-kinetic and Design Analysis of a Sequencing Batch Reactor by Aerobic Granular Sludge (호기성 입상화 슬러지를 이용한 SBR 운전의 동력학적 해석 및 설계분석)

  • Choi, Seong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.275-280
    • /
    • 2011
  • In the present work, the aerobic particle's characteristics were enhanced. A polymer was used to make aerobic granular sludge in short period of time. And operation parameters were calculated for organic matter removal in domestic wastewater using a sequencing batch reactor (SBR). The experiment for sewage (Influent concentration of 63~72 mg COD/L) by using mature aerobic granular sludge showed the organic matter removal rate k and oxygen utilization coefficient a', b' were $10.161d^{-1}$ and 0.87 mg $O_2/mg$ $COD_r$, 0.11 mg $O_2/mg$ MLVSS d respectively. Therefore, it was more effective than K value $5{\sim}8d^{-1}$ of conventional activated sludge process. The sludge synthetic value and sludge auto-oxydation value were 0.45 mg VSS/mg $COD_r$ and 0.05 mg VSS/mg MLVSS d respectively. Consequently, mortality rates of microorganisms was lower than conventional activated sludge process.