• Title/Summary/Keyword: SBOD/TCOD

Search Result 7, Processing Time 0.017 seconds

Treatment of Municipal Sewage Sludge by Ozonization (오존을 이용한 도시하수슬러지의 처리)

  • 윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.83-88
    • /
    • 2002
  • This study was performed to determine the possibility of sludge treatment by ozone for reducing the sludge production in sewage treatment. To evaluate the characteristics of the release of organic matters and nutrient from sludge degradation by ozone, SCOD, SBOD/TCOD, T-N and T-P were analyzed. From the results, we concluded that the concentration of soluble organic matters(SCOD) was increased with reaction time. Also, The concentration of T-N and T-P were increased with time like as organic matters. Quantities of released SCOD, SBOD, T-N and T-P by ozonization were 0.038g, 0.058 g, 0.011 g, 0.012 g per g MLSS, respectively.

Release of Organic Matter and Behavior of Nitrogen in the Degradation of Sewage Sludge Using Ultrasound (초음파를 이용한 하수 슬러지 분해에서 유기물 방출과 질소 거동)

  • Yoon, Yong-Soo;Kang, Gwang-Nam;Choi, Suk-Soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.4
    • /
    • pp.75-80
    • /
    • 2002
  • The sewage sludge with concentrated MLSS, ranging from 5967 to 8400mg/L was degraded by ultrasound. In this study, ultrasound treatment was used to investigate the behavior characterization of SBOD, sludge biodegradation, C/N ratio, TN, turbidity and sludge morphology. From the experimental results of C/N ratio change and TN removal, the optimal irradiation time was found to be 10 minutes. The results showed the relative index of sludge biodegradation(SBOD/TCOD) was enhanced to 0.76 from the initial value of 0.013 at the 5967mg/L MLSS, during the 60minutes treatment. Throughout this research, the results provide useful engineering reference data for reuse of sewage sludge using ultrasound.

  • PDF

Effect of Recalcitrant Organics on Bio-kinetic Coeffcient and Biodegradable in Box-mill Wastewater (판지공장 폐수 중 난분해성 유기물질이 동력학적 계수 및 생분해에 미치는 영향)

  • Cho, Yong Duck;Lee, Sang Wha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.329-338
    • /
    • 2006
  • The research aims to provide the basic data for practical applications by correlating the bio-kinetic coefficients with the load of recalcitrant organic matter in box-mill wastewater. The activated sludge process was employed to a Wastewater disposal plant in an industrial setting, increase of consequently leading to the organic load. The parameter values derived by Monod-kinetic analysis were as follows:specific substrate removal rate $K_{max}=0.17day^{-1}$, half saturation constants $K_s=60.37mg/l$, decay coefficient $K_d=0.142day^{-1}$, microbial yield coefficient y = 0.388mg/mg, and max specific growth rate ${\mu}_{max}=0.006day^{-1}$. In view of biodegradability, the $TCOD_{Mn}/TBOD_5$ ratios of inflow and outflow were 1.07 and 1.41, and the $SCOD_{Mn}/SBOD_5$ ratios of inflow and outflow were 1.10 and 1.50, respectively. The higher $TCOD_{Mn}/TBOD_5$ ratio of outflow indicated that metabolites of a microorganism have accumulated in the cells.

Pre-treatment Characteristics of Night Soil by Microbubble (마이크로버블을 이용한 분뇨의 전처리 특성)

  • Lim, Ji-young;Kim, Hyun-sik;Park, Soo-young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.31-37
    • /
    • 2016
  • This study was conducted to investigate the effect of OH radicals on organic matter oxidation and suspended solids removal using microbubble as a pre-treatment technique to reduce the organic load of night soil in connection with sewage. The experiment was conducted for three months at HRT 4 hours using pressurized type microbubble generator. The mean SS removal efficiency was achieved 71%. The average removal efficiency of $TCOD_{Cr}$, TBOD, TN and TP were achieved for 51.5%, 47.9%, and 14.7% respectively, as scum and SS were removed by flotation separation. The removal efficiency of soluble organic matters were 25.0%, 17.1% for $SCOD_{Cr}$, SBOD by air microbubble supply. Soluble nitrogen and phosphorus were removed average of 11.9% and 7.4%, respectively. As s result, it was confirmed that soluble organic matters were removed by air microbubble supplied. Generated OH radicals when the microbubble was collapsed, can decompose the soluble organic matters. Therefore, The microbubble flotation process was installed at the front of night soil treatment process, it will contribute to the stable operation of the subsequent biological treatment facility by oxidation of the dissolved organic matters as well as removal of SS by flotation separation.

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

A Study on Volume Reduction of Waste Sludge by Aerobic Thermophilic Bacteria (호기성 호열미생물에 의한 하수슬러지 감량화 효율에 관한 연구)

  • Bae, Yoon-Sun;Kim, Soon-Young;Nam, Duck-Hyun;Park, Chul-Hwi;Kim, Jin-Su;Takada, Kazu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.497-505
    • /
    • 2005
  • Domestic Sewage Treatment Plants are mostly based on biological treatment, in which large amounts of excess sludge are generated and occupy about 40 ~ 60% of the total sewage treatment costs. Several methods for sludge treatment has been so far reported as upgrading biodegradation of sludge; heat treatment, chemical treatment, including thermo-alkali and ozone, mechanical treatment including ultrasonic pulverization. But, it has a limitation in case of reducing the amount of excess sludge which are already producted. In this study, application of excess sludge reduction process using thermophilic aerobic bacteria for activated sludge was examined. The research was carried out two different stage. one for a biological wastewater treatment and the other for a thermophilic aerobic solubilization of the waste sludge. A portion of excess sludge from the wastewater treatment step was into the thermophilic aerobic sludge solubilization reactor, in which the injected sludge was solubilized by thermophilic aerobic bacteria. The solubilized sludge was returned to the aeration tank in the wastewater treatment step for its further degradation. Sludge solubilization reactor was operated at $63{\pm}2^{\circ}C$ with hydraulic retention time(HRT) of 1.5 ~ 1.7 day. Control group was operated with activated sludge process(AS) and experiment group was operated with three conditions(RUN 1, RUN 2, RUN3). RUN 1 was operated with AS without sludge solubilization reactor. RUN 2 were operated with AS with sludge solubilization reactor to examine correlation between sludge circulation ratio and sludge reduction ratio by setting up sludge circulation ratio to 3. RUN 3 was operated with sludge circulation ratio of 3 and MLSS concentration of 1,700~2,000mg/L to examine optimum operation condition. The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge The quantity of excess sludge production was reduced sharply and in operation of RUN 3, sludge solubilization ratio and sludge reduction ratio were 53. 7%, 95.2% respectively. After steady state operation, average concentration of TBOD, SBOD, $TCOD_{Cr}$, $SCOD_{Cr}$, TSS, VSS, T-N, T-P of effluent were 4.5, 1.7, 27 .8, 13.8, 8.1, 6.2, 15.1, 1.8mg/L in the control group and were 5.6, 2.0, 28.6, 19.1, 9.7, 7.2, 16.1, 2.0mg/L in the experimental group respectively. They were appropriate to effluent standard of Sewage Treatment Plants.

Behavior and Decomposition Velocity of Pollutants on Various Forms from Domestic Sewage in Small-scale Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 농촌 전원독립가구 하수처리장에서 하수 중 오염물질의 존재형태별 거동과 분해속도)

  • Seo, Dong-Cheol;Kim, Hyung-Jun;Park, Woo-Young;Lim, Jong-Sir;Hwang, Seung-Ha;Park, Chan-Hoon;Choi, Jeong-Hwan;Lee, Hong-Jae;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.18-26
    • /
    • 2008
  • Behavior and decomposition velocity of pollutants on various forms from domestic sewage in sewage treatment plant were investigated in order to obtain the basic data for improving the removal efficiency of pollutants and to reduce the area in constructed wetland by natural purification method. The removal amounts of BODs and CODs in aerobic bed were significantly higher than those of the other beds. In aerobic bed, the removal amounts of IBOD and ICOD were more than those for SBOD and SCOD, respectively, whereas the removal amounts of BODs and CODs in anoxic and anaerobic beds were little different. The removal amounts of SSs in aerobic bed were also higher than those for the other beds, and the removal amounts of VSS in all beds were more than those for FSS. The removal amounts of DTN and DTP in all beds were more than those for STN and STP, respectively. In addition, the decomposition velocities of TBOD, TCOD and TSS in aerobic bed were 30.79, 17.15 and 29.96 $day^{-1}$. Moreover, the decomposition velocities of BODs, CODs and SSs in aerobic bed were very rapid than those in the other beds. On the other hand, the decomposition velocities of BODs, CODs and SSs in anoxic and anaerobic beds were a little different regardless of the forms of pollutant. The decomposition velocities constants of T-N in aerobic, anoxic and anaerobic beds were 4.78, 0.12 and 0.10 $day^{-1}$, respectively. Moreover, the decomposition velocities constants of T-P in aerobic, anoxic and anaerobic beds were 13.09, 0.12 and 0.13 $day^{-1}$ respectively. The decomposition velocity of T-Ns and T-Ps in aerobic bed were slightly rapid than those in the other beds, whereas the decomposition velocities of T-Ns and T-Ps in anoxic and anaerobic beds were slightly different regardless of the forms of pollutant.