Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발)

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.

Measures and Cause Analysis of Electrical Disturbance for Elevator Equipment of the Apartment House (공동주택 승강기 설비의 전기적 장해 원인 분석 및 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Park, Chee-Hyun;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Domestic elevator accidents which are related to human life such as death are occurring steadily. This research measured and analyzed for the quality of power source which has possibility to be associated with fault and malfunction of elevator equipment although it is not direct cause examination. In conclusion, we acquired the result that there is possibility that the quality of power source(Sag, Interruption, Harmonic, Electromagnetism emission waveform, Static electricity etc) has an effect on movement of elevator through examination of three elevator facility models and suggested measures for it. Accordingly, this research result will be used as data to suggest establishment of elevator examination regulations and KS regulations for domestic elevator industry and the least safety of household using elevator.

Genetic characteristics of the Korean isolate KI -1 of Toxoplasma gondii

  • LIN Aifen;SHIN Eun-Hee;KIM Tae-Yun;PARK Jae-Hwan;GUK Sang-Mee;CHAI Jong-Yil
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.1 s.133
    • /
    • pp.27-32
    • /
    • 2005
  • Toxoplasma gondii tachyzoites were isolated from an ocular patient in the Republic of Korea and maintained in the laboratory (designated KI-1). In the present study, its genotype was determined by analyzing dense granule antigen 6 (GRA6) gene and surface antigen 2 (SAG2) gene as typing markers. Digestion of the amplification products of GRA6 and of the 5' and 3' ends of SAG2, respectively, with Mse I, Sau3A I, and Hha I, revealed that KI-1 is included in the genotype I, which includes the worldwide virulent RH strain. In addition, when the whole sequences of the coding regions of SAG1, rhoptry antigen 1 (ROP1), and GRA8 genes of KI-1 were compared with those of RH, minor nucleotide polymorphisms and amino acid substitutions were identified. These results show that KI-1 is a new geographical strain of T. gondii that can be included in the genotype I.

Analytical study on cable shape and its lateral and vertical sags for earth-anchored suspension bridges with spatial cables

  • Gen-min Tian;Wen-ming Zhang;Jia-qi Chang;Zhao Liu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.3
    • /
    • pp.255-272
    • /
    • 2023
  • Spatial cable systems can provide more transverse stiffness and torsional stiffness without sacrificing the vertical bearing capacity compared with conventional vertical cable systems, which is quite lucrative for long-span earth-anchored suspension bridges' development. Higher economy highlights the importance of refined form-finding analysis. Meanwhile, the internal connection between the lateral and vertical sags has not yet been specified. Given this, an analytic algorithm of form-finding for the earth-anchored suspension bridge with spatial cables is proposed in this paper. Through the geometric compatibility condition and mechanical equilibrium condition, the expressions for cable segment, the recurrence relationship between catenary parameters and control equations of spatial cable are established. Additionally, the nonlinear general reduced gradient method is introduced into fast and high-precision numerical analysis. Furthermore, the analytic expression of the lateral and vertical sags is deduced and discussed. This is very significant for the space design above the bridge deck and the optimization of the sag-to-span ratio in the preliminary design stage of the bridge. Finally, the proposed method is verified with the aid of two examples, one being an operational self-anchored suspension bridge (with spatial cables and a 260 m main span), and the other being an earth-anchored suspension bridge under design (with spatial cables and a 500 m main span). The necessity of an iterative calculation for hanger tensions on earth-anchored suspension bridges is confirmed. It is further concluded that the main cable and their connected hangers are in very close inclined planes.

The Significance of Sedation Control in Patients Receiving Mechanical Ventilation

  • Jung, Yun Jung;Chung, Wou Young;Lee, Miyeon;Lee, Keu Sung;Park, Joo Hun;Sheen, Seung Soo;Hwang, Sung Chul;Park, Kwang Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.3
    • /
    • pp.151-161
    • /
    • 2012
  • Background: Adequate assessment and control of sedation play crucial roles in the proper performance of mechanical ventilation. Methods: A total of 30 patients with various pulmonary diseases were prospectively enrolled. The study population was randomized into two groups. The sedation assessment group (SAG) received active protocol-based control of sedation, and in the empiric control group (ECG), the sedation levels were empirically adjusted. Subsequently, daily interruption of sedation (DIS) was conducted in the SAG. Results: In the SAG, the dose of midazolam was significantly reduced by control of sedation (day 1, $1.3{\pm}0.5{\mu}g/kg/min$; day 2, $0.9{\pm}0.4{\mu}g/kg/min$; p<0.01), and was significantly lower than the ECG on day 2 (p<0.01). Likewise, on day 2, sedation levels were significantly lower in the SAG than in the ECG. Significant relationship was found between Ramsay sedation scale and Richmond agitation-sedation scale (RASS; $r_s$=-0.57), Ramsay Sedation Scale and Bispectral Index (BIS; $r_s$=0.77), and RASS and BIS ($r_s$=-0.79). In 10 patients, who didn't require re-sedation after DIS, BIS showed the earliest and most significant changes among the sedation scales. Ventilatory parameters showed significant but less prominent changes, and hemodynamic parameters didn't show significant changes. No seriously adverse events ensued after the implementation of DIS. Conclusion: Active assessment and control of sedation significantly reduced the dosage of sedatives in patients receiving mechanical ventilation. DIS, conducted in limited cases, suggested its potential efficacy and tolerability.

The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System (영상성분을 고려한 DVR 기기 해석)

  • Jeong, Il-Yeop;Park, Sang-Yeong;Won, Dong-Jun;Mun, Seung-Il;Park, Jong-Geun;Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

Genotyping of Toxoplasma gondii from Rats (Rattus rattus) in Riyadh, Saudi Arabia

  • Elamin, Maha H.
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.3
    • /
    • pp.257-261
    • /
    • 2014
  • Toxoplasma 3 main clonal lineages are designated as type I, II, and III; however, atypical and mixed genotypes were also reported. This study was conducted for detection of Toxoplasma gondii genotypes in rats (Rattus rattus) in Riyadh region, Saudi Arabia. PCR test on T. gondii B1 gene was conducted on ELISA IgM positive samples for confirmation of the infection. However, genetic analysis of the SAG2 locus was performed to determine T. gondii genotypes using PCR-RFLP technique. PCR test on T. gondii B1gene showed that 22 (81.5%) out of the 27 ELISA IgM positive samples have T. gondii DNA. Genotypic analysis shows that, of the total 22 PCR positive samples, only 13 (59.1%) were of type II, 7 (31.8%) were of type III, and 2 (9.1%) were of an unknown genotype. It is obvious that the prevalence of both type II and III is high in rats. No reports have been available on T. gondii genotypes among rats in Riyadh region, and only little is known about its seroprevalence in rats. Future studies on T. gondii genotypes in rats using multi-locus markers is needed in Riyadh region, Saudi Arabia for better understanding of T. gondii pathogenesis and treatment in humans and animals.

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

Gene typing of staphylococcal superantigens produced by Staphylococcus aureus isolates from meat (식육유래의 Staphylococcus aureus으로부터 산생되는 staphylococcal superantigens의 유전자형 분석)

  • Yoon, Jang-won;Jung, Suk-chan;Yang, Soo-jin;Jung, Byong-youel;Seo, Keon-suk;Kim, So-hyun;Park, Yong-ho
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.553-558
    • /
    • 1998
  • Using the previous established multiplex PCR (mPCR), the presence of six kinds of staphylococcal superantigen (SAg) genes was investigated for nineteen Staphylococcus aureus isolates from the commercialized meat sources. As a result, only one isolate from pork among 19 S aureus isolates (5.3%) was confirmed as a potential SAg producer and harbored sec gene. The results in this study suggest that meat may not be major contagion of staphylococcal food poisoning (SFP) in Korea and that staphylococcal enterotoxin type C may be associated with the disease. Also, the mPCR method in this study can be a useful genotypic method which can overcome the typical disadvantages of conventional antibody-based methods due to antigenic homology, and furthur survey on food-borne S aureus isolates can provide the important epidemiological data for SFP in Korea.

  • PDF

Effects of geometric shape of LWSCR (lazy-wave steel catenary riser) on its global performance and structural behavior

  • Kim, Seungjun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.8 no.3
    • /
    • pp.247-279
    • /
    • 2018
  • This study aims to investigate the behavioral characteristics of the LWSCR (lazy-wave steel catenary riser) for a turret-moored FPSO (Floating Production Storage Offloading) by using fully-coupled hull-mooring-riser dynamic simulation program in time domain. In particular, the effects of initial geometric profile on the global performance and structural behavior are investigated in depth to have an insight for optimal design. In this regard, a systematic parametric study with varying the initial curvature of sag and arch bend and initial position of touch down point (TDP) is conducted for 100-yr wind-wave-current (WWC) hurricane condition. The FPSO motions, riser dynamics, constituent structural stress results, accumulated fatigue damage of the LWSCR are presented and analyzed to draw a general trend of the relationship between the LWSCR geometric parameters and the resulting dynamic/structural performance. According to this study, the initial curvature of the sag and arch bend plays an important role in absorbing transferred platform motions, while the position of TDP mainly affects the change of static-stress level.