• 제목/요약/키워드: SAG3

검색결과 237건 처리시간 0.026초

Analysis of System Impact of the Distributed Generation Using EMTP with Particular Reference to Voltage Sag

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.122-128
    • /
    • 2004
  • With the advent of distributed generation, power systems are fundamentally impacted in regards to stability and power quality. Distributed generation has a positive impact on system restoration following a fault, higher reliability, and mitigation of effect due to voltage sag. However, distributed generation also has a negative impact on decrease of reliability such as changes of protective device setting and mal-operation. Because bulk power systems consist of various sources and loads, it becomes complicated to analyze a power system with distributed generation. The types of distributed generation are usually classified by both rotating machinery and the inverter-based system. In this paper, distributed generation is designed by rotating machinery, and the distributed system having a model of the distributed generation is simulated using EMTP. In addition, this paper presents the simulation results according to the types of distributed generation.

The Circuit Parameters Determination of Voltage-Sag Compensator (순간전압강하 보상기의 회로파라미터 설정)

  • Kim, Hong-Kwon;Lee, Eun-Woong;Lim, Su-Saeng;Kim, Jun-Ho;Jeon, Bok-Su
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.795-797
    • /
    • 2000
  • The analysis model of voltage-sag compensator is achieved in synchronous rotating coordinates. Inverter's LC filter and DC-link capacitor is designed in order to reduce THD of output voltages and LC filter's size And the circuit parameters of voltage-sag compensator is presented for 3-phase Customer.

  • PDF

Rectangular Microlens array for Multi Chip LED Packaing (LED 패키지를 위한 사각 형상의 마이크로 렌즈)

  • Lim C.H.;Jeung W.K.;Choi S.M.;Oh Y.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.882-884
    • /
    • 2005
  • A new rectangular shape microlens array having high sag for solid-state lighting is presented. Proposed microlens, which has high sag, over $375{\mu}m$ and large diameter, over 3 mm can enormously enhance output optical extraction efficiency. Rectangular shape of microlens can maximize the fill factor of light-emitting-diode (LED) package and minimize the optical loss at the same time. This wafer level microlens array is fabricated on LED package. It has many advantages in optical properties, low cost, high aligning accuracy, and mass production.

  • PDF

Toxoplasmosis in a Pet Peach-Faced Lovebird (Agapornis roseicollis)

  • Cooper, Madalyn K.;Slapeta, Jan;Donahoe, Shannon L.;Phalen, David N.
    • Parasites, Hosts and Diseases
    • /
    • 제53권6호
    • /
    • pp.749-753
    • /
    • 2015
  • Toxoplasma gondii atypical type II genotype was diagnosed in a pet peach-faced lovebird (Agapornis roseicollis) based on histopathology, immunohistochemistry, and multilocus DNA typing. The bird presented with severe neurological signs, and hematology was suggestive of chronic granulomatous disease. Gross post-mortem examination revealed cerebral hemorrhage, splenomegaly, hepatitis, and thickening of the right ventricular free wall. Histologic sections of the most significant lesions in the brain revealed intralesional protozoan organisms associated with malacia, spongiform changes, and a mild histiocytic response, indicative of diffuse, non-suppurative encephalitis. Immunohistochemistry confirmed the causative organisms to be T. gondii. DNA isolated from the brain was used to confirm the presence of T. gondii DNA. Multilocus genotyping based on SAG1, altSAG2, SAG3, BTUB, GRA6, c22-8, c29-2, L358, PK1, and Apico markers demonstrated the presence of ToxoDB PCR-RFLP genotype #3 and B1 gene as atypical T. gondii type II. The atypical type II strain has been previously documented in Australian wildlife, indicating an environmental transmission route.

Development of Uninterruptible Power Supply with Voltage Sag Restorer Function (순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제63권2호
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

Effect of Anterior Guidance Change on the Condylar Path in Skeletal Class I Young Adult Women Using a Splint with Flat or Steep Anterior Guidance

  • Choi, Byung-Taek;Baek, Seung-Hak
    • Journal of Korean Dental Science
    • /
    • 제5권1호
    • /
    • pp.29-36
    • /
    • 2012
  • Purpose: To investigate the effects of anterior guidance (AG) change on the working (WCP) and non-working condylar paths (NWCP), and lower incisor path (LIP) using a splint with flat (FAG) or steep AG (SAG). Materials and Methods: The samples consisted of six young adult women (mean age=$23.5{\pm}3.3$ years). Inclusion criteria were skeletal Class I and normodivergent pattern, normal overbite/overjet, minimal slide from retruded cuspal position to intercuspal position, no temporomandibular disorder signs and symptoms, mutually protected occlusion, and minimal tooth wear. After the values of natural AG (NAG) were obtained as a reference for each patient, two types of splints ($15^{\circ}$ flatter and steeper than NAG) were made. After insertion of the splints with FAG or SAG, the WCP, NWCP, and LIP were recorded five times for each patient using an ultrasonic AQR (SAM, Munich, Germany) and statistical analysis was subsequently performed. Result: NAG exhibited postero-superior movement in the WCP and did not show a noticeable immediate side shift (ISS) or difference between the eccentric (EP) and returning paths (RP) in the NWCP. FAG was associated with an irregular and excessive WCP, an increase in ISS, and a difference between EP and RP in the NWCP. SAG showed minimal WCP movement and a decrease in the extent of difference between EP and RP in the NWCP. LIP showed significant differences in EP and in RP (P<0.001, all; FAG

Conventional Anchorage Reinforcement vs. Orthodontic Mini-implant: Comparison of Posterior Anchorage Loss During the En Masse Retraction of the Upper Anterior Teeth

  • Baek, Seung-Hak;Kim, Young-Ho
    • Journal of Korean Dental Science
    • /
    • 제3권1호
    • /
    • pp.5-10
    • /
    • 2010
  • This study sought to compare the amounts of posterior anchorage loss during the en masse retraction of the upper anterior teeth between orthodontic mini-implant (OMI) and conventional anchorage reinforcement (CAR) such as headgear and/or transpalatal arch. The subjects were 52 adult female patients treated with sliding mechanics (MBT brackets, .022" slot, .019X.025" stainless steel wire, 3M-Unitek, Monrovia, CA, USA). They were allocated into Group 1 (N=24, Class I malocclusion (CI), upper and lower first premolar (UP1LP1) extraction, and CAR), Group 2 (N=15, Cl, UP1LP1 extraction and OMI), and Group 3 (N=13, Class II division 1 malocclusion, upper first and lower second premolar extraction, and OMI). Lateral cephalograms were taken before (T0) and after treatment (T1). A total of 11 anchorage variables were measured. Analysis of variance was used for statistical analysis. There was no significant difference in treatment duration and anchorage variables at T0 among the three groups. Groups 2 and 3 showed significantly larger retraction of the upper incisor edge (U1E-sag, 9.3mm:7.3mm, P<.05) and less posterior anchorage loss (U6M-sag, 0.7~0.9mm:2mm, P<.05; U6A-sag, 0.5mm:2mm, P<.01) than Group 1. The ratio of retraction amount of the upper incisor edge per 1 of anchorage loss in the upper molar made for the significant difference between Groups 1 and 2 (4.6mm:7.0mm, P<.05). Group 3 showed a relatively distal inclination of the upper molar (P<.05) and the intrusion of the upper incisor and first molar (U1E-ver, P<.05; U6F-ver, P<.05) compared to Groups 1 and 2. Although OMI could not shorten the treatment duration, it could provide better maximum posterior anchorage than CAR.

  • PDF

Numerical parametric analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips

  • Zhang, Yingying;Song, Xiaoguang;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • 제63권2호
    • /
    • pp.195-206
    • /
    • 2017
  • This paper presents the parametric numerical analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips. The effects of several factors on failure modes and ultimate bearing capacity of the purlins are studied, including setup of anti-sag bar, purlin type, sheet thickness and connection type et al. A simplified design formula is proposed for predicting the ultimate bearing capacity of purlins. Results show that setting the anti-sag bars can improve the ultimate bearing capacity and change the failure modes of C purlins significantly. The failure modes and ultimate bearing capacity of C purlins are significantly different from those of Z purlins, in the purlin-sheet roof connected by standing seam clips. Setting the anti-sag bars near the lower flange is more favorable for increasing the ultimate bearing capacity of purlins. The ultimate bearing capacity of C purlins increases slightly with sheet thickness increasing from 0.6 mm to 0.8 mm. The ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips is always higher than those by self-drilling screws. The predictions of the proposed design formulas are relatively in good agreement with those of EN 1993-1-3: 2006, compared with GB 50018-2002.

Extensional and Complex Viscosities of Linear and Branched Polycarbonate Blends

  • Park, Jung-Hoon;Hyun, Jae-Chun;Kim, Woo-Nyon;Kim, Sung-Ryong;Ryu, Seung-Chan
    • Macromolecular Research
    • /
    • 제10권3호
    • /
    • pp.135-139
    • /
    • 2002
  • Blends of the linear bisphenol-A polycarbonate (L-PC) and randomly branched bisphenol-A polycarbonate (Br-PC), prepared by co-rotating twin screw extrusion, were investigated using differential scanning calorimetry (DSC), sag resistance time tester, extensional rheometry, and advanced rheometric expansion system (ARES). From the DSC results, the glass transition temperature (T$_{g}$) of the L-PC/Br-PC blend was increased with the increase of Br-PC in the blend, and the blend showed a single T$_{g}$, which suggests a miscible blend. The sag resistance time of the L-PC/Br-PC blend was increased with the increase of Br-PC in the blends. From the results of rheological measurements of the L-PC/Br-PC blends, the extensional viscosity and the complex viscosity of the blends were found to increase with the increase of Br-PC in the blends. The increase of extensional viscosity and complex viscosity was related with the increase of sag resistance time with the Br-PC in the L-PC/Br-PC blends.nds.

Analysis of Output Voltage Variation of a Voltage Disturbance Generator according to the Load Power Factor in Voltage Sag and Swell Mode (전압 새그 및 스웰 발생 모드에서 부하역률에 따른 전압외란 발생기의 출력전압 변동 해석)

  • Han, Heung-Soo;Jeong, Hye-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, Heung-Geun;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제21권1호
    • /
    • pp.80-87
    • /
    • 2016
  • This study investigates output voltage variation of a voltage disturbance generator in case of sag and swell modes. The generator uses series transformers and silicon-controlled rectifier thyristors to provide voltage disturbance; consequently, voltage drop at the output terminal is inevitable. On the basis of the analysis, voltage drop increases as the power factor decreases in lagging. Voltage drop is 3.7 [%] at a power factor (lagging) of 0.8. Simulation and experimental results show the validity of the analysis.