• Title/Summary/Keyword: SAG3

Search Result 240, Processing Time 0.035 seconds

Chemical and Gelation characteristics of Pectins Obtained from Ripened and Unripened Crabapples (과일 내의 pectin 함량 및 성숙도에 따른 pectin 특성 변화에 관한 연구)

  • 문수재
    • Journal of the Korean Home Economics Association
    • /
    • v.19 no.4
    • /
    • pp.33-39
    • /
    • 1981
  • This study was attempted to determine the pectin contents of various fruits(Cherry, strawberry, plum, peach, apricot, apple, crabapple) and to investigate the changes in the properties of pectin and pectin gel during crabapple ripening. Methoxyl content, molecular weight and intrinsic viscosity were measured in ripened and unripened crabapples. In order to determine the characteristics of pectin gel, percent sag was measured by exchange Ridgelimeter, hardness and textural characteristics of jellies were measured by a penetrometer and a texturometer. The experimental results are summarized as follows: 1. The pectin contents of various fruits were 1.16% for cherry, 3.17% fir strawberry, 4.29% for plum, 5.51% for apricot, and pectin contents of peaches and apples varies depends on varieties from 4.54% to 5.61% to 6.52, respectively. The pectin contents of unripened and ripened crabapple wee 9.21% and 9.84% respectively, indicating that pectin content increased with fruit maturity. 2. The methoxyl contents, which was 6.61%~6.95%, was very low and it increased significantly during fruit ripening. Further, a decrease in acetyl content, intrinsic viscosity, molecular weight occurred during the ripening of crabapples. 3. The percent sag of crabapple jellies increased with fruit maturity from 5.26% to 5.79%, and the corresponding jelly grade decreased in ripened crabapple. 4. The hardness of jellies determined by a penetrometer was 79.15 pp.U. for ripened crabapple jelly, 90.62 pp.U. for unripe ned crabapple jelly. 5. In the textural characteristics of gels measured by a texturometer, the gels made from unripened crabapple were shown to have the highest values in hardness, cohesiveness, adhesiveness and gumminess.

  • PDF

The characteristics of the multi-span suspension bridge with double main cables in the vertical plane

  • Zhang, Li-Wen;Xiao, Ru-Cheng;Jiang, Yang;Chai, Sheng-Bo
    • Structural Engineering and Mechanics
    • /
    • v.42 no.3
    • /
    • pp.291-311
    • /
    • 2012
  • The multi-span suspension bridge having double main cables in the vertical plane is investigated regarding endurance of live load distribution in the case of non-displaced pylon and pylon displacement. The coefficient formula of live load distribution described as the ratio of live load on the bottom cable to the top cable is obtained. Based on this formula, some function in respect of this bridge are derived and used to analyze its characteristics. This analysis targets the cable force, the cable sag and the horizontal displacement at the pylon top under live load etc. The results clarified that the performance of the live load distribution and the horizontal force of cables in the case of non-deformed pylon has a similar tendency to those in the case of deformed pylon, and the increase of pylon rigidity can increase live load distributed to the bottom cable and slightly raise the cable horizontal force under live load. However, effect on the vertical rigidity of bridge and the horizontal force increment of cables caused by live load is different in the case of non-deformed pylon and deformed pylon.

Characteristics of selective area growth of GaN/AlGaN double heterostructure grown by hydride vapor phase epitaxy on r-plane sapphire substrate (HVPE 방법에 의해 r-plane 사파이어 기판 위의 선택 성장된 GaN/AlGaN 이종 접합구조의 특성)

  • Hong, S.H.;Jeon, H.S.;Han, Y.H.;Kim, E.J.;Lee, A.R.;Kim, K.H.;Hwang, S.L.;Ha, H.;Ahn, H.S.;Yang, M.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.1
    • /
    • pp.6-10
    • /
    • 2009
  • In this paper, a selective area growth (SAG) of a GaN/AlGaN double heterostructure (DH) has been performed on r-plane sapphire substrate by using the mixed-source hydride vapor phase epitaxy (HVPE) with multi-sliding boat system. The SAG-GaN/AlGaN DH consists of GaN buffer layer, Te-doped AlGaN n-cladding layer, GaN active layer, Mg-doped AlGaN p-cladding layer, and Mg-doped GaN p-capping layer. The electroluminescence (EL) characteristics show an emission peak of wavelength, 439 nm with a full width at half maximum (FWHM) of approximately 0.64 eV at 20 mA. The I-V measurements show that the turn-on voltage of the SAG-GaN/AlGaN DH is 3.4 V at room temperature. We found that the mixed-source HVPE method with a multi-sliding boat system was one of promising growth methods for III-Nitride LEDs.

Implementation and Experiment of 10kW 3-phase sag voltage compensator (10kW급 3상 새그전압 보상기 구현 및 실험)

  • Chae, Seungwoo;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.247-248
    • /
    • 2011
  • 본 논문에서는 10kW급 3상 새그전압 보상기를 구현함에 있어 필요한 알고리즘인 새그 검출기법, 양방향 싸이리스터를 통한 계통 차단, RMS 출력전압 제어기법을 논의한다. 시작품을 제작하여 실험을 거쳐 타당성 및 안정성을 검증하였다.

  • PDF

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

Static Analysis of Cable-Stayed Bridges (사장교(斜張橋)의 정적해석(靜的解析)에 관한 연구(研究))

  • Hwang, Hak Joo;Song, Jae Ho;Joo, Sun Man;Kim, Yun Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.4
    • /
    • pp.71-81
    • /
    • 1983
  • This paper was mainly concentrated On the structural analysis of the cable-stayed bridges through the linear and nonlinear analysis method. And also this compares and analyses the characteristics of the two typical system, the radiating and harp arrangement. As a result, The radiating configuration is stiffer than the harp configuration in many respects Besides, the difference between the linear and nonlinear analysis method is proportional to the sag. But as the cable of the cable-stayed bridges is tauter, the difference is lesser.

  • PDF

Genotyping of a Korean isolate of Toxoplasma gondii by multilocus PCR-RFLP and microsatellite analysis

  • Quan, Juan-Hua;Kim, Tae-Yun;Choi, In-Uk;Lee, Young-Ha
    • Parasites, Hosts and Diseases
    • /
    • v.46 no.2
    • /
    • pp.105-108
    • /
    • 2008
  • Although the Korean isolate KI-1 of Toxoplasma gondii has been considered to be a virulent type I lineage because of its virulent clinical manifestations, its genotype is unclear. In the present study, genotyping of the KI-1 was performed by multilocus PCR-RFLP and microsatellite sequencing. For 9 genetic markers (c22-8, c29-2, L358, PK1, SAG2, SAG3, GRA6, BTUB, and Apico), the KI-1 and RH strains exhibited typical PCR-RFLP patterns identical to the type I strains. DNA sequencing of tandem repeats in 5 microsatellite markers (B17, B18, TUB2, W35, and TgM-A) of the KI-1 also revealed patterns characteristic of the type I. These results provide strong genetic evidence that KI-1 is a type I lineage of T. gondii.

Genotype of Toxoplasma gondii from Blood of Stray Cats in Gyeonggi-do, Korea

  • Kim, Hye-Youn;Kim, Yun-Ah;Lee, Ho-Sa;Rhie, Ho-Gun;Cho, Shin-Hyeong;Yu, Jae-Ran;Lee, Sang-Eun
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.4
    • /
    • pp.413-415
    • /
    • 2009
  • Genotyping of Toxoplasma gondii has been performed in 23 PCR positive blood samples from stray cats in Korea. We used 2 separate PCR-restriction fragment length polymorphism (RFLP) patterns of SAG2 gene, amplifying the 5' and 3' ends of the locus. The results revealed that all samples belonged to the type I clonal lineage. Although T. gondii organisms were not isolated from the samples, the results of the present study represent that stray cats with T. gondii infection should be seriously concerned in our environment. Adequate and continuous control programs of stray cats are needed to reduce the risk of transmission of T. gondii as a zoonotic infection threatening the public health.

Study of structural parameters on the aerodynamic stability of three-tower suspension bridge

  • Zhang, Xin-Jun
    • Wind and Structures
    • /
    • v.13 no.5
    • /
    • pp.471-485
    • /
    • 2010
  • In comparison with the common two-tower suspension bridge, due to the lack of effective longitudinal restraint of the center tower, the three-tower suspension bridge becomes a structural system with greater flexibility, and more susceptible to the wind action. By taking a three-tower suspension bridge-the Taizhou Bridge over the Yangtze River with two main spans of 1080 m as example, effects of structural parameters including the cable sag to span ratio, the side to main span ratio, the deck's dead load, the deck's bearing system, longitudinal structural form of the center tower and the cable system on the aerodynamic stability of the bridge are investigated numerically by 3D nonlinear aerodynamic stability analysis, the favorable structural system of three-tower suspension bridge with good wind stability is discussed. The results show that good aerodynamic stability can be obtained for three-tower suspension bridge as the cable sag to span ratio is assumed ranging from 1/10 to 1/11, the central buckle are provided between main cables and the deck at midpoint of main spans, the longitudinal bending stiffness of the center tower is strengthened, and the spatial cable system or double cable system is employed.