• Title/Summary/Keyword: SA channel

Search Result 69, Processing Time 0.034 seconds

Analyzing nuclear reactor simulation data and uncertainty with the group method of data handling

  • Radaideh, Majdi I.;Kozlowski, Tomasz
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.287-295
    • /
    • 2020
  • Group method of data handling (GMDH) is considered one of the earliest deep learning methods. Deep learning gained additional interest in today's applications due to its capability to handle complex and high dimensional problems. In this study, multi-layer GMDH networks are used to perform uncertainty quantification (UQ) and sensitivity analysis (SA) of nuclear reactor simulations. GMDH is utilized as a surrogate/metamodel to replace high fidelity computer models with cheap-to-evaluate surrogate models, which facilitate UQ and SA tasks (e.g. variance decomposition, uncertainty propagation, etc.). GMDH performance is validated through two UQ applications in reactor simulations: (1) low dimensional input space (two-phase flow in a reactor channel), and (2) high dimensional space (8-group homogenized cross-sections). In both applications, GMDH networks show very good performance with small mean absolute and squared errors as well as high accuracy in capturing the target variance. GMDH is utilized afterward to perform UQ tasks such as variance decomposition through Sobol indices, and GMDH-based uncertainty propagation with large number of samples. GMDH performance is also compared to other surrogates including Gaussian processes and polynomial chaos expansions. The comparison shows that GMDH has competitive performance with the other methods for the low dimensional problem, and reliable performance for the high dimensional problem.

Design and Performance Evaluation of Multilevel LDPC Codes (다중 레벨 LDPC 부호의 설계 및 성능 분석)

  • ;Yu Yi;Jia Hou
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • We design multilevel coding(MLC) with a semi bit-interleaved coded modulation(BICM) scheme based on low density parity check(LDPC) codes. Different from traditional designs, we joint the MLC and BICM together by using the Gray mapping, which can transmit the multimedia data over several equivalent channels with different code rates. To get a good performance from signal-to-noise ratio(SNR) very close to the capacity of the additive white Gaussian noise(AWGN) channel, random regular LDPC code and a simple semi-algebra LDPC(SA-LDPC) code are discussed in MLC with parallel independent decoding(PID). Finally, the numerical results demonstrate that the proposed scheme could achieve both power and bandwidth efficiency for multimedia communication system.

Performance Analysis of CSMA/CD in Radio Environment with Capture Effect (무선환경에서 포획효과를 고려한 CSMA/CD 프로토콜의 성능분석)

  • Sa, Ju-Hee;Hyun, In-Bok;Kwak, Kyung-Sup
    • Journal of IKEEE
    • /
    • v.1 no.1 s.1
    • /
    • pp.73-82
    • /
    • 1997
  • In this paper we analyzed, using Markov modeling, the performance of CSMA/CD over the wireless channel which is characterized by near-far effect, shadowing and Rayleigh fading. The analysis shows that throughput of CSMA/CD is degraded by channel error. However, if capture effect which arises from the randomness of power level of received signal due to the fading phenomena of electromagnetic waves is taken into consideration, the system performance is much improved and the system stability is also made better.

  • PDF

Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor (페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정)

  • Lee, Sa-Ya;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF

Uncertainties impact on the major FOMs for severe accidents in CANDU 6 nuclear power plant

  • R.M. Nistor-Vlad;D. Dupleac;G.L. Pavel
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2670-2677
    • /
    • 2023
  • In the nuclear safety studies, a new trend refers to the evaluation of uncertainties as a mandatory component of best-estimate safety analysis which is a modern and technically consistent approach being known as BEPU (Best Estimate Plus Uncertainty). The major objectives of this study consist in performing a study of uncertainties/sensitivities of the major analysis results for a generic CANDU 6 Nuclear Power Plant during Station Blackout (SBO) progression to understand and characterize the sources of uncertainties and their effects on the key figure-of-merits (FOMs) predictions in severe accidents (SA). The FOMs of interest are hydrogen mass generation and event timings such as the first fuel channel failure time, beginning of the core disassembly time, core collapse time and calandria vessel failure time. The outcomes of the study, will allow an improvement of capabilities and expertise to perform uncertainty and sensitivity analysis with severe accident codes for CANDU 6 Nuclear Power Plant.

Solution-Processed Inorganic Thin Film Transistors Fabricated from Butylamine-Capped Indium-Doped Zinc Oxide Nanocrystals

  • Pham, Hien Thu;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.494-500
    • /
    • 2014
  • Indium-doped zinc oxide nanocrystals (IZO NCs), capped with stearic acid (SA) of different sizes, were synthesized using a hot injection method in a noncoordinating solvent 1-octadecene (ODE). The ligand exchange process was employed to modify the surface of IZO NCs by replacing the longer-chain ligand of stearic acid with the shorter-chain ligand of butylamine (BA). It should be noted that the ligand-exchange percentage was observed to be 75%. The change of particle size, morphology, and crystal structures were obtained using a field emission scanning electron microscope (FE-SEM) and X-ray diffraction pattern results. In our study, the 5 nm and 10 nm IZO NCs capped with stearic acid (SA-IZO) were ligand-exchanged with butylamine (BA), and were then spin-coated on a thermal oxide ($SiO_2$) gate insulator to fabricate a thin film transistor (TFT) device. The films were then annealed at various temperatures: $350^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, and $600^{\circ}C$. All samples showed semiconducting behavior and exhibited n-channel TFT. Curing temperature dependent on mobility was observed. Interestingly, mobility decreases with the increasing size of NCs from 5 to 10 nm. Miller-Abrahams hopping formalism was employed to explain the hopping mechanism insight our IZO NC films. By focusing on the effect of size, different curing temperatures, electron coupling, tunneling rate, and inter-NC separation, we found that the decrease in electron mobility for larger NCs was due to smaller electronic coupling.

PERFORMANCE OF FIMS MICROCHANNEL PLATE DETECTOR SYSTEM (FIMS의 마이크로채널 플레이트 검출기 시스템의 특성)

  • Nam, U.W.;Rhee, J.G.;Kong, K.N.;Park, Y.S.;Jin, K.C.;Jin, H.;Park, J.H.;Yuk, I.S.;Seon, K.I.;Han, W.;Lee, D.H.;Ryu, K.S.;Min, K.W.;Edelstein, J.;Korpela, E.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • We describe some performance of the detector electronics system for the FIMS (Far-ultraviolet Imaging Spectrograph) mission. The FIMS mission to map the far ultraviolet sky uses MCP (micro-channel plate) detectors with a crossed delay line anode to record photon arrival events. FIMS has two MCP detectors, each with a ~25mm$\times$25mm active area. The unconventional anode design allows for the use of a single set of position encoding electronics for both detector fields. The centroid position of the charge cloud, generated by the photon-stimulated MCP, is determined by measuring the arrival times at both ends of the anode following amplification and external delay. The temporal response of the detector electronics system determines the readout's positional resolution for the charge centroid. High temporal resolution (<$35{\times}75$ps FWHM) and low power consumption (< 6W) were achieved for the FIMS detector electronics system.

fMRI Study on the Brain Activity Induced by Manual Acpuncture at BL62 (신맥(申脈) 혈위자극이 fMRI상 뇌활성화 변화에 미치는 영향 연구)

  • Rheu, Kyoung-Hwan;Choi, Il-Hwan;Park, Hi-Joon;Lim, Sa-Bi-Na
    • Korean Journal of Acupuncture
    • /
    • v.23 no.2
    • /
    • pp.89-103
    • /
    • 2006
  • Objectives: Recently, the effect of acupuncture has been approved not only in the East but also in the West, so the interest on acupuncture was greatly improved. Especially, functional magnetic resonance imaging(fMRI) was embossed as the study tool for the mechanism of acupuncture noninvasively and many studies on the mechanism of acupuncture using fMRI were carried out. We archived the fMRI study on the brain activity induced by manual acupuncture at BL62(申脈). Methods: The study was the acupuncture at BL62(申脈) and we acquired 9 fMRI results from 6 persons$(age\;20{\sim}30,\;4\;male\;and\;2\;female)$. These studies employed The block design for mapping brain activity and acupuncture was perfomed at BL62(申脈) on the left foot. Results: The brain related motor function was cerebellum, basal ganglia and cerebral cortex and thalamus connected these elements. In the result of this study, the regions of significant activation in the cerebellum was centered on the spinocerebellum in the anterior lobe, so we presumed that this result showed the input of stimulation by the acupuncture on BL62(申脈). But basal ganglia and cerebral cortex showed the regions of significant activation in the left larger than the right and regions of the cerebral cortex was the motor and sensory cortex. Such a result explained that acupuncture at BL62(申脈) could have influence the motor function and acupuncture at left BL62(申脈) could affect the right side through the activation of the left basal ganglia and cerebral cortex. Conclusions: In the theory of crossing needling at collaterals(繆刺論), it the pathogenic factor invaded in the Yang Heel channel(陽?脈) that was one of the eight Extra meridians(奇經八脈), we recognized the disease of the collateral channel and used contralateral BL62(申脈) for treatment of the Yang Heel channel(陽?脈). Moreover the result of this study could bear the construction that acupuncture at the left BL62(申脈) treats the contralateral lesion and this construction is related to the theory of crossing needling at collaterals(繆刺論).

  • PDF

Removal Efficiency of Heavy Metals in Acidic Mine Drainage from Microbial Mats (바이오매트 형성에 의한 산성광산배수 내 중금속 유출질량 제거효율)

  • Yu, Hun-Sun;Kwon, Byung-Hyuk;Kim, Park-Sa;So, Yoon-Hwan;Kang, Dong-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.667-676
    • /
    • 2012
  • This research investigated to reduce mass of heavy metals in AMD(acid mine drainage) by microbial mats formed on the channel bed. As, Cd, Cu, Fe, Mn and Zn components were monitored in water and microbial mats, at three points (AMD1, AMD2 and AMD3), in a total of six times. Average daily discharge mass of heavy metals was highest in July, Fe component contained more than 76% of total discharge mass. Discharge mass of heavy metals of AMD and heavy metal contents in microbial mats decreased with downstream at channel. Heavy metal components that average daily discharge mass is over 0.5 kg were Fe, Cu and Zn, and they were highest in July. Average removal efficiency of heavy metals in AMD was highest about 21% in Fe, this microbial mats were due to form from precipitation of Fe component in AMD by aerobic iron bacteria. Relative content for As component in microbial mats than AMD was over 16 times, this As components were due to absorb at iron oxide and iron hydroxide on the surface of microbial mats.

The Relativity between the Circulating Pattern of the Channels, the Collaterals, and the Movement Distinction of YoungGi, and WiGi (경맥(經脈)과 락맥(絡脈)의 순행(循行) 양식(樣式)과 영.위기(營.衛氣)의 운행(運行) 특징(特徵)의 상관성(相觀性)에 대한 고찰(考察))

  • Kang, Dong-Yoon;Jo, Hak-Jun
    • Journal of Korean Medical classics
    • /
    • v.19 no.2 s.33
    • /
    • pp.30-45
    • /
    • 2006
  • Analyzed the subject of ‘To heart' meridian system(向心服系), and 'Circulating' meridian system(備環服系), and considered relativity between the circulating pattern of the channels, the collaterals and the circulating distinction YoungGi (營氣), WiGi(衛氣). The subject of 'To heart' meridian system is WiGi, and this system is similiar to the moving pattern of the fifteen major collaterals(十五絡服). The subject of 'Circulating' meridian system is YoungGi, and this system is same with the moving pattern of the twelve regular channels(十二經脈). YoungGi and WiGi have the same origin, and they are intrinsic one thing with functional ambivalency. It is WiGi, the subject of the movement of Collateral, because it is identical the moving pattern of Collaterals(絡服) and that of WiGi as the subject of the movement of Collateral. It is YoungGi, the subject of movement of Channel because it is identical the moving pattern of Channels(經服) and that of YoungGi. It can be defined that Wigi as the subject of the movement of Collateral, also YoungGi as the subject of movement of Channel, but that is from i 염 function and action, there's no need to be separated within the framework of going through Meridian. YoungSuBosa(迎隨補鴻) in acupuncture, defines its basis not only on the moving direction of YoungGi, but on combinated difference between the directions, moments, and sex. Until now it is under discussion the rights and wrongs, It's not contradictory concept between two basis of YoungSuBoSa, from the thought the distinct movement of WiGi and the circulation pattern of Collaterals have no specified directions.

  • PDF