• Title/Summary/Keyword: S.O.T. Technique

Search Result 138, Processing Time 0.027 seconds

Evaluation of O-MAR XD Technique for Reduction of Magnetic Susceptibility Artifact of Knee Implant (인공 무릎관절에서 자화율 인공물의 감소를 위한 O-MAR XD 기법의 평가)

  • Lee, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.413-419
    • /
    • 2018
  • Magnetic Resonance Imaging for patients with metallic implant has poor image quality, and signal loss and artifacts including distortion can occur. The purpose of this study is to carry out a comparative evaluation on high receive bandwidth(hiBW), O-MAR, O-MAR XD to reduce artifacts in knee implant. To take MRI, 3.0T scanner and dual-source radiofrequency transmission were used. O-MAR XD technique's strong option showed a significant difference (p<0.001) with O-MAR XD technique's weak option, O-MAR and hiBW excluding the medium option. O-MAR XD's medium option had a significant difference (p<0.01) with O-MAR XD's weak, O-MAR and hiBW. O-MAR XD technique's weak option had a significant difference (p<0.01) with O-MAR XD's strong and medium options, O-MAR and hiBW. O-MAR technique had a significant difference (p<0.001) with strong, medium, weak options of O-MAR XD technique except for hiBW. HiBW had a significant difference (p<0.001) with strong, medium and weak options of O-MAR XD technique except for O-MAR. The results showed that O-MAR XD technique was more useful for MRI scan for patients with knee replacement surgery than traditional techniques such as hiBW or O-MAR, and susceptibility artifacts decreased more when O-MAR XD technique's strong or medium option was applied. Based on the results above, it is considered that it will be possible to acquire images whose susceptibility artifacts were highly decreased by using O-MAR XD technique's strong or medium option when conducting MRI for artificial knee joint and it will be helpful for checking and monitoring patients with knee joint replacement.

A Surface Generation Velocity Measurement Technique Using the Buried Channel MOS Structure (Buried Channel MOS 구조를 이용한 표면생성속도 측정 방법)

  • 조성호;허연철;이종덕
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.7
    • /
    • pp.56-63
    • /
    • 1992
  • A measurement technique of the surface generation velocity S$_o$ using the BC(buried channel) MOS structure with shallow and low doped channel layer (BC MOS S$_o$ measurement technique) is presented and verified analytically and experimentally. Using this measurement technique, S$_o$ can be measured more accurately than that measured using the gate-controlled diode SS1oT measurement technique. When S$_o$ is measured for the two techniques from a BC MOS structure test patten with gate length of 171$\mu$m, the results are 0,66cm/sec and 0.28cm/sec for the former and the latter respectively.

  • PDF

Clinical Case study of Conservative Caring Method to Abnormal Knee Flexion in Standing Position (기립상태에서 비정상적 무릎관절 굴곡에 대한 보존적 치료 임상사례연구)

  • Cho, Il-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.1
    • /
    • pp.323-330
    • /
    • 2009
  • Objectives: There are many reasons to restrict extension of knee. Unless we can find any structural deformities from patients, we don't have any clue of helping this condition except give them some instruction of exercise of strengthening anterior thigh muscles and releasing extensor muscle group of lower extremities. In this study, the author reports new case, using technique of releasing restriction of knee movement based on Sacro Occipital Technique. Method: From the day of notifying 14yrs. old patient's extension restriction of knee, it had have 7 trials of having S.O.T category Ⅰ. technique procedure. Result: The patient can stand without extension restriction of knee. Conclusion: In many case, muscle soft tissue work helps releasing hamstring tension so that we can make patient stand with straightly extended knee position but if this method is not working then S.O.T category Ⅰ. technique procedure may be considerable to improve this condition.

Comparison between C.M.R.T. and acupuncture in the treatment of liver dysfunction (간 기능 이상 치료에 대한 C.M.R.T. 치료 부위(T8 횡돌기)와 경혈과의 비교)

  • Sim Young;Lee Jun-Moo
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.97-117
    • /
    • 2002
  • Chiropractic is very similar to Oriental Medicine in philosophy on the cause of diseases and in utilization of spinal articulations for diagnosis and treatment. In this paper the spinal area used to treat liver dysfunction in S.O.T. technique, one of chiropractic techniques, was compared to the acupncture points used to cure the same conditions. Because both Oriental medicine and Chiropractic are dealing with autonomic nervous system in regulating abnormal conditions, also the innervation of spinal nerves to those areas was checked. The spinal area that S.O.T. technique utilizes to correct liver dysfunction is transverse processes of T8, which corresponds to B16. Acupncture points from this level down to T12/L1, which are B16, B17, B18, B19, B20, B21, B45, B46, B47, B48, B49, B50, GV6, GV7, GV8 and GV9, all have been applied to control liver function. Apparent discrepency exists in therapeutic areas for liver malfunction between the two natural healing arts. According to the neurology texts, liver is innervated by sympathetic fibers from the 7th-10th thoracic segments and by parasympathetic fibers from vagus nerve. Sympathetic afferent nerves from the liver reach the 7th-12th thoracic spinal cord segments. It can be said all the 7th-12th thoracic spinal cord segments are related to liver function. Therefore the areas used for liver dysfunction in both natural medicine are appropriately selected. However, B16, the Oriental medical equivalent of the main spinal area which is used for lowered liver function in C.M.R.T. Technique, is not utilized as frequent as in Oriental medicine.

  • PDF

Characterization of ZnO Thin Films prepared by Pulsed Laser Deposition Technique (PLD 기술로 제작된 ZnO 박막의 특성)

  • No, In-Jun;Shin, Paik-Kyun;Lee, Neung-Heon;Kim, Yong-Hyuk;Ji, Seung-Han;Lee, Sang-Hee;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1404-1405
    • /
    • 2006
  • Transparent ZnO thin films were deposited on quartz substrates by a KrF pulsed laser deposition (PLD) technique with different process conditions such as substrate temperature ($T_s$) and oxygen ambient pressure ($pO_2$). Surface morphology, crystal structure, and electrical properties of the ZnO films were investigated in order to characterize their thin film properties. The pulsed laser deposited ZnO films showed highly c-oriented crystalline structures depending on the process conditions: the highest FWHM (Full Width Half Maximum) value of (002) peak was observed for the ZnO film prepared at $T_{s}=550^{\circ}C$, $pO_2$=5mTorr and laser fluence of $2J/cm^2$.

  • PDF

Correlation between Electrical Conduction and Dielectric Relaxation in the Glass System $Cul-Cu_2S-Cu_2O-MoO_3$ ($Cul-Cu_2S-Cu_2O-MoO_3$계 유리의 전기전도 및 유전환화와의 상관)

  • 이재형;임기조
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1152-1157
    • /
    • 1994
  • The glasses were prpared in the system CuI-CuS12TS-CuS12TO-MoOS13T by rapid quenching technique. These glasses have high ionic conductivities at 2$0^{\circ}C$ in the range of 10S0-1T[S/m], and the conductivities increase with increasing CuI and CuS12TS content. The value of activation energy for dielectric relaxation is nearly identical with that for conductivity. The cole-Cole parameter $\beta$ for representation of the distribution of dielectric relaxation times varies the range from 0.92 to 0.96. This parameter has a weak dependence on the composition of glass, and is independent of temperature. The correlation factors P for the glasses shows from 1.1 to 1.7.

  • PDF

Dynamic deformation behavior of aluminum alloys under high strain rate compressive/tensile loading (상용 알루미늄 합금의 고속 인장/압축 변형거동 규명)

  • Lee, O.S.;Kim, G.H.;Kim, M.S.;Hwang, S.W.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.268-273
    • /
    • 2000
  • Mechanical properties of the materials used for transportations and industrial machinery under high strain rate loading conditions are required to provide appropriate safety assessment to these mechanical structures. The Split Hopkinson Pressure Bar(SHPB) technique, a special experimental apparatus, can be used to obtain the material behavior under high strain rate loading condition. In this paper, dynamic deformation behaviors of the aluminum alloys, Al2024-T4, Al6061-T6 and Al7075-T6, under high strain rate compressive and tensile loading are determined using SHPB technique.

  • PDF

Choice technique develovement of transformer core (변압기 코아의 선정 기술 개발)

  • Lee, O.K.;Kim, S.Y.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1604-1606
    • /
    • 2003
  • In this paper, investigated the core of transformer of high power factor and high effectiveness about design and choice technology. Transformer that use existent general core and material is high no-load loss power. Presented core choice method that can reduce loss. Could do to reduce loss according to choice technology of use material more than about 10 (%). Presented classification and check list by Core's type.

  • PDF

A Stydy on the Wetting of Ceramic Oxides by Molten Metal (용융금속에 의한 Ceramic Oxides에서의 Wetting에 관한 연구)

  • Lee, Seok-Keun;Lim, Eung-Keuk;Kim, Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.4
    • /
    • pp.289-296
    • /
    • 1983
  • The Wetting of fusion cast $Al_2O_3$ brick and $Al_2O_3 -ZrO_2$ brick by liquid Ag was studied by the sessile drop technique in Ar atmosphere. In this experiment the specimens were photographed per 2$0^{\circ}C$with increasing temperature from 96$0^{\circ}C$ melting point of Ag. And the method of photographing was carried out by shadow technique. The cosine of the contact angle increased linearly with increasing temperature in both systems. And the relation between the cosine of the contact angle and the temperature was Cos$\theta$=1.132+$0.75{\times}10^{-3}T$ for $Al_2O_3$ brick and Cos$\theta$=-1.706+$1.125{\times}10^{-3}T$ for $Al_2O_3 -ZrO_2$ brick In both systems the contact angle decreased as the surface of substrate became smoother. The work of adhesion which was 503.5ergs/$cm^2$ for $Al_2O_3$brick and 393.6 ergs/cm2 for $Al_2O_3 -ZrO_2$ brick at 96$0^{\circ}C$ increased parabolically with increasing temperature in both system.

  • PDF

Service based Disk I/O Control supporting Predictable I/O Bandwidth (예측 가능한 입출력 대역폭을 제공하는 서비스 기반의 디스크 입출력 제어)

  • Kang, Dong-Jae;Lee, Pyoung-Hwa;Jung, Sung-In
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.11
    • /
    • pp.1594-1609
    • /
    • 2010
  • In the case that multiple services are in race condition for limited I/O resource, the services or processes with lower priority occasionally occupy most of limited I/O resource. And it decreases QoS and performance of important services and makes it difficult to efficiently use limited I/O resource. Although system administrator allocates I/O resource according to priority of process, he/she can't know or expect how much resource will be used by the specific process. Due to these reasons, it causes the problem that he/she can't guarantee the service QoS and performance stability. Therefore, in this paper, we propose service based disk I/O control supporting predictable I/O bandwidth to resolve upper problems. Proposed I/O control guarantees the service QoS and performance stability by supporting the service based predictable I/O bandwidth and it makes limited I/O resource to be efficiently used in respect of service.