• Title/Summary/Keyword: S-parameter measurement

Search Result 379, Processing Time 0.027 seconds

SLA Parameter Measurement Of Policy Routing Network (Policy Routing Network에서의 SLA 파라메터 측정)

  • Shim, Hoi-Jung;Nam, Ji-Seung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.10b
    • /
    • pp.1597-1600
    • /
    • 2001
  • In-Service-Monitoring을 통하여 네트웍 계층에서 성능저하와 전달되어지는 QOS의 영향을 감시하여 Pro-Active 매니지먼트가 가능하다. 그 결과로서 SLA 보증을 위반하기 전에 성능저하를 조기 발견하여 행동을 취한 수 있게 한다. 본 논문에서는 사용자의 요구조건을 만족하기 위한 네트웍의 구성과 SLA 측정의 제약조건들을 고려하고 Policy Based Routing이 적용되는 네트웍에서 Technology-Specific Parameter인 IP Packet Loss Ratio, IP 패킷전송지연, 패킷지터, 가용도등의 SLA Parameter를 측정하였다.

  • PDF

Mixed-mode S-parameter Measurement System of Twisted Pairs (연선의 혼합 모드 산란 계수 측정 시스템)

  • Ahn, Jungsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.888-894
    • /
    • 2018
  • In this paper, we proposed a mixed-mode s-parameter measurement system for measuring the performance of twisted pairs. A twisted pair is a balanced type component, its characteristics can not be directly measured using network analyzer, which is generally implemented as a unbalanced type. It is possible to convert between balanced signal and unbalanced signal by using a balun but it restricts the frequency range of the measurement system. The proposed system measures the performance of twisted pairs by measuring mixed-mode s-parameters using a 4-port vector network analyzer and a designed fixture, without using a balun. We measured the performance of a commercial Ethernet cable and compared with the results which measured by using baluns. The results showed that the proposed system is capable of measuring the performance of twisted pairs.

Study on Calibration for Parallel-Typed Tilting Table (병렬기구형 틸팅 테이블의 보정에 관한 연구)

  • Kim, T.S.;Jung, J.W.;Kim, Y.H.;Park, K.W.;Lee, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1512-1517
    • /
    • 2003
  • This paper presents the calibration for the parallel typed tilting table. The calibration system needs only simple sensing device which is a digital indicator to measure the orientation of a table. The calibration algorithm is developed by a measurement operator. It eliminates the concern about the poor parameter observability due to a large number of parameters of parallel-mechanism. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a Parallel-typed Tilting Table and all the necessary kinematic parameters are identifiable.

  • PDF

Development of Magnus Effect Measurement Technique for Spinning Projectile (회전 발사체용 마그너스 효과 특정기법의 개발)

  • Oh, Se-Yoon;Kim, Sung-Cheol;Lee, Do-Kwan;Choi, Joon-Ho;Ahn, Seung-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.1
    • /
    • pp.79-86
    • /
    • 2007
  • The Magnus effect measurement apparatus was designed and built for spinning wind tunnel model which would simulate the rotation of projectiles. Prior to the high speed test, the ground functional test and the low speed test were carried out in the Agency for Defense Development's Low Speed Wind Tunnel(ADD-LSWT) at spin rates from about 6,000 to 10,000 rpm. Magnus force and moment were measured on the spinning projectile model at velocity of 100 m/s. It was shown that the Magnus force and moment were linear function of spin parameter. The test results were compared with Magnus test run on the same configuration in the Arnold Engineering Development Center's Propulsion Tunnel 4T(AEDC-4T).

Scattering Parameter-based Measurement of Planar EMI filter

  • Wang, Shishan;Gong, Min;Xu, Chenchen
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.806-813
    • /
    • 2014
  • Planar electromagnetic interference (EMI) filters are widely used to restrain the conducted EMI of switching power supplies. Such filters are characterized by small size, low parasitic parameters, and better high-frequency performance than the passive discrete EMI filter. However, EMI filter performance cannot be exactly predicted by using existing methods. Therefore, this paper proposes a method to use scattering parameters (S-parameters) for the measurement of EMI filter performance. A planar EMI filter sample is established. From this sample, the relationship between S-parameters and insertion gain (IG) of EMI filter is derived. To determine the IG under different impedances, the EMI filter is theoretically calculated and practically measured. The differential structure of the near-field coupling model is also deduced, and the IG is calculated under standard impedance conditions. The calculated results and actual measurements are compared to verify the feasibility of the theory.

Development of Sensible Brassiere for Middle Aged Women -Investigation of consumer's Needs and Evaluation of Commercial Brassiere for the Development of Subjective Measurement Scale and Screening of Design Parameters- (중년 여성의 감성 Brassiere 개발(제1보) -소비자 요구 분석을 기초로 한 제품 디자인 요소 추출-)

  • 김정화;이선영;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.5
    • /
    • pp.714-723
    • /
    • 2000
  • The purpose of this study is to develop functional and sensible brassiere for middle-aged women. As a methodology, engineering design process, especially, QFD(Quality Function Deployment) was adopted to translate consumer's needs into product design parameters. Wearing tests of commercial brassiere were performed for the development o subjective measurement scale. The environmental condition was controlled at 28$\pm$1$^{\circ}C$, 65$\pm$3%RH. As results, subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. Regression equations with the subjective evaluation descriptors were developed for the prediction of wearing comfort of brassiere. (R2=.82) The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Measurement Error Model with Skewed Normal Distribution (왜도정규분포 기반의 측정오차모형)

  • Heo, Tae-Young;Choi, Jungsoon;Park, Man Sik
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.953-958
    • /
    • 2013
  • This study suggests a measurement error model based on skewed normal distribution instead of normal distribution to identify slope parameter properties in a simple liner regression model. We prove that the slope parameter in a simple linear regression model is underestimated.

Modal Testing of Mechanical Structures Subject to Operational Excitation Forces

  • Gade, Svend;Moller, Nis B.;Herlufsen, Henrik;Brincker, Rune;Andersen, Palle
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1162-1165
    • /
    • 2001
  • Operational Modal Analysis also known as Output Only Modal Analysis has in the recent years been used for extracting modal parameters of civil engineering structures and is now becoming popular for mechanical structures. The advantage of the method is that no artificial excitation need to be applied to the structure or force signals to be measured. All the parameter estimation is based upon the response signals, thereby minimising the work of preparation for the test. This test case is a controlled lab set-up enabling different parameter estimation methods techniques to be used and compared to the Operational Modal Analysis. For Operational Modal Analysis two different estimation techniques are used: a non-parametric technique based on Frequency Domain Decomposition (FDD), and a parametric technique working on the raw data in time domain, a data driven Stochastic Subspace Identification (SS!) algorithm. These are compared to other methods such as traditional Modal Analysis.

  • PDF

Finite Element Modeling and Parameter Measurements of Synchronous Reluctance Motor (자기저항 동기전동기의 유한요소 모델링 및 정수 측정)

  • Hong, J.P.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.22-24
    • /
    • 1998
  • The Synchronous reluctance motor is a sinewave ac motor and it has cylindrical surfaces on both sides of the air gap. The stator is a conventional polyphase ac stator, while the rotor has internal flux barriers shaped to maximize the ratio of d-axis to g-axis reactance. This paper presents the finite element analysis and parameter measurement of the synchronous reluctance motor(SRM). The model motor is a 3-phase SRM with the segmental rotor and its rating is 0.175kw. The torque characteristic is analysed by finite element method and compared with that from measurement.

  • PDF