• 제목/요약/키워드: S-acts

검색결과 1,203건 처리시간 0.028초

통계적 기법을 이용한 화자변화 검출 실험 (A Speaker Change Detection Experiment that Uses a Statistical Method)

  • 이경록;김진영
    • 음성과학
    • /
    • 제8권4호
    • /
    • pp.59-72
    • /
    • 2001
  • In this paper, we experimented with speaker change detection that uses a statistical method for NOD (News On Demand) service. A specified speaker's change can find out content of each data in speech if analysed because it means change of data contents in news data. Speaker change detection acts as preprocessor that divide input speech by speaker. This is an important preprocessor phase for speaker tracking. We detected speaker change using GLR(generalized likelihood ratio) distance base division and BIC (Bayesian information criterion) base division among matrix method. An experiment verified speaker change point using BIC base division after divide by speaker unit using GLR distance base method first. In the experimental result, FAR (False Alarm Rate) was 63.29 in high noise environment and FAR was 54.28 in low noise environment in MDR (Missed Detection Rate) 15% neighborhood.

  • PDF

Ca 첨가에 의한 $BaTiO_3$의 환원억제기구 (The Role of Calcium as a Reduction Inhibitor in $BaTiO_3$)

  • 황연;김윤호;박순자
    • 한국세라믹학회지
    • /
    • 제27권6호
    • /
    • pp.741-746
    • /
    • 1990
  • Dielectrics which do not lose their high insulation resistance in reducing atmosphere are necessary for multilayer ceramic capacitors with Ni internal electrode. In this study we investigated the Ca ion site occupancy in A-site excess Ca-doped BaTiO3 by measuring the insulation resistance, lattice constant and Curie temperature. Its Curie temperature, which was lower than that of the pure BaTiO3, was more lowered by sintering in reducing atmosphere. Lattice constnat of c-axis decreased and that of a-axis increased, suggesting substitution of Ca ions for Ti ions. Hence CaTi" acts as an acceptor to maintain high insulation resistance.ance.

  • PDF

수용가용 직접부하제어시스템의 구성 및 운영 (Composition and Operation of Direct Load Control(DLC) System for use of Demand Side)

  • 박종찬;최문규;이용균;김선자;정병환;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1260-1262
    • /
    • 2004
  • Direct Load Control(DLC) system is a load management program for stablization of electric power supply-demand. It is a series of acts limiting the demand of selected demand side at peak load or other time periods. Recently, power supply-demand instability due to dramatic increase in power usage such as summertime air-conditioning load has brought forecasts of decrease in power supply capability. Therefore heightening the load factor through systematic load management, in other words, Direct Load Control became necessary. By examining the composition and operation of the DLC system, this paper provides conceptional understanding of the DLC system and help in system research.

  • PDF

Micro Fabrication Process of Powder Compact with Semi-solid Mold

  • Tsumori, Fujio
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.258-259
    • /
    • 2006
  • New powder compaction process, in which a Bingham semi-solid/fluid mold is utilized, is developed to fabricate micro parts. In the present process, a powder material is filled as slurry in a solid wax mold, dried and compressed. The wax is heated during compaction and becomes semi-solid state, which can acts as a pressurized medium for isostatic compaction. Since the compacted micro parts are very fragile, the mold's temperature is controlled to higher than its melting point during unloading, to avoid breakage of the compacts. To demonstrate effectiveness of this process, some micro compacts of alumina are shown as examples.

  • PDF

[6]-Gingerol Attenuates Radiation-induced Cytotoxicity and Oxidative Stress in HepG2 Cells

  • Chung, Dong-Min;Uddin, S.M. Nasir;Kim, Jin Kyu
    • 환경생물
    • /
    • 제31권4호
    • /
    • pp.376-382
    • /
    • 2013
  • [6]-Gingerol, a major polyphenol of ginger (Zingiber officinale), exhibits a variety of biological properties including anti-oxidant, anti-inflammatory and anti-cancer activity. However, the radioprotective effect of [6]-gingerol is still unknown. The aim of this study was to investigate the radioprotective effect of [6]-gingerol against radiation-induced cell cytotoxicity and oxidative stress in HepG2 cells. [6]-Gingerol pretreatment attenuated radiation-induced cell cytotoxicity caused by 5Gy (half lethal dose, $LD_{50}$ of HepG2 cells). The measurements of superoxide dismutase (SOD) and catalase (CAT) activity were also performed. The results showed that [6]-gingerol pretreatment reduced increasing SOD and CAT activity after exposure of IR, indicating that [6]-gingerol protected oxidative stress by regulating cellular antioxidant enzyme (SOD and CAT) activity. These findings suggest that [6]-gingerol acts as a radioprotector by attenuating cell cytotoxicity and oxidative stress.

EFFECT OF THE DIFFERENTIAL PRESSURE BY THE BLOW-BY GAS FLOW ON THE PCV VALVE WITH A CRACK

  • Song, S.M.;Kwon, O.H.;Lee, Y.W.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.219-224
    • /
    • 2007
  • Recently, atmospheric contaminations has become worse due to the increased number of automobile. The PCV (Positive Crankcase Ventilation) valve acts as a flow control to allow re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. Also, during the fabrication of the PCV valve, micro cracks may occur in the valve body and be extended under operation. The excessive stress distribution and crack initiation on the PCV valve body would bring an unstable blow-by gas flow rate control and would cause valve failure. The purpose of this study is to examine the crack affects on the stress and strain variations on the PCV valve according to the inlet and outlet manifold under differential pressures. From the results, we can explain the behavior of the crack extension for a safe condition of PCV valve.

Heterarchical SFCS를 위한 ICPL 개발에 관한 연구 (Development of ICPL for Heterarchical SFCS)

  • 권성필;조현보;정무영
    • 대한산업공학회지
    • /
    • 제25권2호
    • /
    • pp.150-161
    • /
    • 1999
  • This paper deals with the design and development of a real-time integrated communication architecture for heterarchical SFCS(Shop Floor Control System). In autonomous agent-based heterarchical SFCS, each functional unit of parts and resources is equipped with an intelligent controller (agent) that acts as the representative of the entity. The controllers communicate and negotiate with other controllers on a real-time basis through message passing and bidding protocol to achieve mutual agreements for task sharing. ICPL(Integrated Communication Protocol and Language) is proposed for this purpose. ICPL is a language and a protocol for supporting communication among intelligent controllers. Based on the speech act theory, this paper proposes a semantic description for ICPL that associates the description of the cognitive states of controllers with the use of language primitives (message_type). Semantics for the basic set of ICPL messages is described. Eventually, an ICPL-based communication architecture can provide the implementation of the distributed and heterarchical SFCS, and makes the intelligent controller transparent to the negotiation problem.

  • PDF

사고사례에 기초한 보일러 사고의 원인분석 및 대책 (Cause Analyses of Boiler Accident and Their Counter-plans Based on Accident Cases)

  • 윤상권;장통일;임현교
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.131-140
    • /
    • 2003
  • An accident involving a boiler can result in a disaster since it handles high-pressurized steam so that it may cause an explosion. Therefore, the boiler is very susceptible to industrial accidents. This thesis aimed to develop counter-plans to prevent industrial accidents involved the boiler. At first after collecting accident cases involving boilers, a survey on the trait of them was carried out. Ant on the other hand a qualitative analysis was conducted to draw out hazardous components in the boiler itself and their inherent relative importance was assessed. Through this procedure, 'negligence of unsafe condition' was noted as the major cause for unsafe acts whereas 'fault in work procedure' for unsafe condition. In the meanwhile, results of a hazard analysis using FMEA technique ranked gas safety devices, a switch preventing gas from under-pressurization, protect relays high. In particular, it was pointed out that the water feeding and steam subsystem has more components in hazard than other subsystems. Considering these analyses results, counter-plans to improve safety management was suggested also.

SDN 플로우 테이블 제한에 따른 리소스 어택 (Resource Attack Based On Flow Table Limitation in SDN)

  • 뉴엔 트리 투안 힙;김경백
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 추계학술발표대회
    • /
    • pp.215-217
    • /
    • 2014
  • In Software Defined Network (SDN), data plane and control plane are decoupled. Dummy switches on the data plane simply forward packet based on the flow entries that are stored in its flow table. The flow entries are generated by a centralized controller that acts as a brain of the network. However, the size of flow table is limited and it can conduct a security issue related to Distributed Denial of Service (DDoS). Especially, it related to resource attack that consumes all flow table resource and consumes controller resources. In this paper, we will analyze the impact of flow table limitation to the controller. Then we propose an approach that is called Flow Table Management to handle flow table limitation.

Effects of Added Anions on the Reaction of Nitrous Acid with Hydrogen Peroxide

  • Park, Jong-Yoon;Choi, Eun-Jin;Park, Joon-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권1호
    • /
    • pp.37-41
    • /
    • 1992
  • The reactions of nitrous acid with hydrogen peroxide in acidic aqueous solution in the presence of several added anions have been studied at $0^{\circ}C$ and pH 2-4 to investigate the nucleophilic catalysis of these anions. From the dependence of reaction rates on the anion concentrations, significant catalytic effects were found for $Cl^-,\;Br^-,\;SCN^-$, in order of effect $SCN^-\;{\approx}\;Br^->Cl^-$, while no observable effect was found for ${ClO_4}^-$ and ${NO_3}^-$. These results support O-nitrosation reaction is the rate-determining step and NOX formed in the presence of an anion ($X^-$) also acts as a nitrosating agent and accelerates the overall reaction rate. The order of reactivity was found to be NOCl>NOBr>NOSCN, which is consistent with the results of N-nitrosation and S-nitrosation reactions.