• Title/Summary/Keyword: S-V agreement

Search Result 234, Processing Time 0.041 seconds

A study on transport and plugging of sodium aerosol in leak paths of concrete blocks

  • Sujatha Pavan Narayanam;Soubhadra Sen;Kalpana Kumari;Amit Kumar;Usha Pujala;V. Subramanian;S. Chandrasekharan;R. Preetha;B. Venkatraman
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.132-140
    • /
    • 2024
  • In the event of a severe accident in Sodium Cooled Fast Reactors (SFR), the sodium combustion aerosols along with fission product aerosols would migrate to the environment through leak paths of the Reactor Containment Building (RCB) concrete wall under positive pressure. Understanding the characteristics of sodium aerosol transport through concrete leak paths is important as it governs the environmental source term. In this context, experiments are conducted to study the influence of various parameters like pressure, initial mass concentration, leak path diameter, humidity etc., on the transport and deposition of sodium aerosols in straight leak paths of concrete. The leak paths in concrete specimens are prepared by casting and the diameter of the leak path is measured using thermography technique. Aerosol transport experiments are conducted to measure the transported and plugged aerosol mass in the leak paths and corresponding plugging times. The values of differential pressure, aerosol concentration and relative humidity taken for the study are in the ranges 10-15 kPa, 0.65-3.04 g/m3 and 30-90% respectively. These observations are numerically simulated using 1-Dimensional transport equation. The simulated values are compared with the experimental results and reasonable agreement among them is observed. From the safety assessment view of reactor, the approach presented here is conservative as it is with straight leak paths.

Isolation of a Quinone-rich Fraction from Ardisia crispa Roots and its Attenuating Effects on Murine Skin Tumorigenesis

  • Yeong, Looi Ting;Hamid, Roslida Abdul;Yazan, Latifah Saiful;Khaza'ai, Huzwah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2301-2305
    • /
    • 2013
  • Ardisia crispa (Family: Myrsinaceae) is an evergreen, fruiting shrub that has been traditionally used as folklore medicine. Despite a scarcity of research publications, we have succeeded in showing suppressive effects on murine skin papillomagenesis. In extension, the present research was aimed at determining the effect of a quinone-rich fraction (QRF) isolated from the same root hexane extract on both initiation and promotion stages of carcinogenesis, at the selected dose of 30 mg/kg. Mice (groups I-IV) were initiated with a single dose of 7,12-dimethylbenz(${\alpha}$)anthracene (DMBA, $100{\mu}g/100{\mu}l$) followed by repeated promotion of croton oil (1%) twice weekly for 20 weeks. In addition, group I (anti-initiation) received QRF 7 days before and after DMBA; group II (anti-promotion) received QRF 30 minutes before each croton oil application; group III (anti-initiation/promotion) was treated with QRF as a combination of group I and II. A further two groups served as vehicle control (group V) and treated control (group VI). As carcinogen control, group IV showed the highest tumor volume ($8.79{\pm}5.44$) and tumor burden ($3.60{\pm}1.17$). Comparatively, group III revealed only 20% of tumor incidence, tumor burden ($3.00{\pm}1.00$) and tumor volume ($2.40{\pm}1.12$), which were significantly different from group IV. Group II also showed significant reduction of tumor volume (3.11), tumor burden (3.00) and tumor incidence (11.11%), along with prominent increase of latency period of tumor formation (week 12). Group I, nonetheless, demonstrated marked increment of tumor incidence by 40% with prompted latency period of tumor formation (week 7). No tumor formation was observed in groups V and VI. This study provided clear evidence of inhibitory effects of QRF during promotion period which was in agreement with our previous findings. The mechanism(s) underlying such effects have yet to be elucidated.

Precision Validation of Electromagnetic Physics in Geant4 Simulation for Proton Therapy (양성자 치료 전산모사를 위한 Geant4 전자기 물리 모델 정확성 검증)

  • Park, So-Hyun;Rah, Jeong-Eun;Shin, Jung-Wook;Park, Sung-Yong;Yoon, Sei-Chul;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.225-234
    • /
    • 2009
  • Geant4 (GEometry ANd Tracking) provides various packages specialized in modeling electromagnetic interactions. The validation of Geant4 physics models is a significant issue for the applications of Geant4 based simulation in medical physics. The purpose of this study is to evaluate accuracy of Geant4 electromagnetic physics for proton therapy. The validation was performed both the Continuous slowing down approximation (CSDA) range and the stopping power. In each test, the reliability of the electromagnetic models in a selected group of materials was evaluated such as water, bone, adipose tissue and various atomic elements. Results of Geant4 simulation were compared with the National Institute of Standards and Technology (NIST) reference data. As results of comparison about water, bone and adipose tissue, average percent difference of CSDA range were presented 1.0%, 1.4% and 1.4%, respectively. Average percent difference of stopping power were presented 0.7%, 1.0% and 1.3%, respectively. The data were analyzed through the kolmogorov-smirnov Goodness-of-Fit statistical analysis test. All the results from electromagnetic models showed a good agreement with the reference data, where all the corresponding p-values are higher than the confidence level $\alpha=0.05$ set.

  • PDF

Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays (Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율)

  • Kim, Wuon-Shik;Hah, Suck-Ho;Hwang, Sun-Tae;Oh, Jang-Jin;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Central axis percentage depth-doses, P(%), were measured at the points from the 2.5cm depth of reference point to 20 cm depth with 2.5 cm interval. Distance from the X-ray target to the water phantom($30{\times}30{\times}30cm^3$) surface was 1 m, and at this point three different beam sizes of $5cm{\phi},\;10cm{\phi},\;and\;15cm{\phi}$ were used. While the X-ray tube voltage varied from 150 to 250 kV, the tube current remained constant at 5 mA. Absorbed dose rate in water, $\dot{D}_w$, was determined using the air kerma calibration factor, $N_k$, which was derived from the exposure calibration factor, $N_x$, of the NE 2571 ion chamber. The reference exposure rate, $\dot{X}_c$, was measured using the Exradin A-2 ion chamber calibrated at ETL, Japan. The half value layers of the X-rays determined to meet ETL calibration qualities. The absorbed dose rates determined at the calibration point were compared to the values obtained from Burlin's general cavity theory, and the percentage depth-dose values determined from $N_k$ showed a good agreement with the values of the published depth dose data(BJR Suppl. 17).

  • PDF

A Study on Mental Injury Suffered by Passengers in International Air law (국제항공법상 정신적 손해에 관한 연구)

  • Cho, Hong-Je;Ahn, Jin-Young
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.1
    • /
    • pp.55-95
    • /
    • 2010
  • The meaning and application of 'lesion corporelle' in the context of a variety of mental or psychic injuries is less clear, while there is very little disagreement about its literal translation. U.S. Court decisions since Floyd allow recovery for a range of claims involving emotional injury under Article 17; in some cases there is no recovery, while in others there is full recovery, depending on the allegations and the nexus between the alleged injury and any related or accompanying physical injury. Courts are in agreement that pure emotional injury is not compensable under the Convention. Most courts agree that emotional injury is not compensable in those cases where it has resulted only in physical manifestations such as weight loss or sleeplessness. At the same time, most courts generally agree that emotional injury is compensable if it proximately flows from a physical injury. The issue as to whether the courts would associate PTSD with bodily injury as envisioned in the present Warsaw structure or even the new regime reflected in the Convention proposed by ICAO would largely depend on the extent to which courts would be ready to embrace the compelling scientific findings with regard to mental distress and its application within the term 'bodily injury'. Taken together, these points when the current under Article 17 of the Warsaw Convention, 'physical injury' notion of 'mental injury' is to be extended. Of course, the current terms of the Warsaw Convention have been maintaining a precedent for many countries appear to have a statue of the original purpose of the treaty does not contribute to the diffusion. Therefore, in future treaties 'bodily injury', the term 'injury', the term 'personal injury' or 'health undermined' the term should be replaced or revised.

  • PDF

Orthophoto and DEM Generation Using Low Specification UAV Images from Different Altitudes (고도가 다른 저사양 UAV 영상을 이용한 정사영상 및 DEM 제작)

  • Lee, Ki Rim;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.5
    • /
    • pp.535-544
    • /
    • 2016
  • Even though existing methods for orthophoto production using expensive aircraft are effective in large areas, they are drawbacks when dealing with renew quickly according to geographic features. But, as UAV(Unmanned Aerial Vehicle) technology has advanced rapidly, and also by loading sensors such as GPS and IMU, they are evaluates that these UAV and sensor technology can substitute expensive traditional aerial photogrammetry. Orthophoto production by using UAV has advantages that spatial information of small area can be updated quickly. But in the case of existing researches, images of same altitude are used in orthophoto generation, they are drawbacks about repetition of data and renewal of data. In this study, we targeted about small slope area, and by using low-end UAV, generated orthophoto and DEM(Digital Elevation Model) through different altitudinal images. The RMSE of the check points is σh = 0.023m on a horizontal plane and σv = 0.049m on a vertical plane. This maximum value and mean RMSE are in accordance with the working rule agreement for the aerial photogrammetry of the National Geographic Information Institute(NGII) on a 1/500 scale digital map. This paper suggests that generate orthophoto of high accuracy using a different altitude images. Reducing the repetition of data through images of different altitude and provide the informations about the spatial information quickly.

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

Manual Liquid Based Cytology in Primary Screening for Cervical Cancer - a Cost Effective Preposition for Scarce Resource Settings

  • Nandini, N.M.;Nandish, S.M.;Pallavi, P.;Akshatha, S.K.;Chandrashekhar, A.P.;Anjali, S.;Dhar, Murali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3645-3651
    • /
    • 2012
  • Conventional pap smear (CPS) examination has been the mainstay for early detection of cervical cancer. However, its widespread use has not been possible due to the inherent limitations, like presence of obscuring blood and inflammation, reducing its sensitivity considerably. Automated methods in use in developed countries may not be affordable in the developing countries due to paucity of resources. On the other hand, manual liquid based cytology (MLBC) is a technique that is cost effective and improves detection of precursor lesions and specimen adequacy. Therefore the aim of the study was to compare the utility of MLBC with that of CPS in cervical cancer screening. A prospective study of 100 cases through MLBC and CPS was conducted from October 2009 to July 2010, in a Medical College in India, by two independent pathologists and correlated with histopathology (22 cases). Morphological features as seen through MLBC and CPS were compared. Subsequently, all the cases were grouped based on cytological diagnosis according to two methods into 10 groups and a subjective comparison was made. In order to compare the validity of MLBC with CPS in case of major diagnoses, sensitivity and specificity of the two methods were estimated considering histological examination as the gold standard. Increased detection rate with MLBC was 150%. The concordance rate by LBC/histopathology v/s CPS/histopathology was also improved (86% vs 77%) The percentage agreement by the two methods was 68%. MLBC was more sensitive in diagnosis of LSIL and more specific in the diagnosis of inflammation. Thus, MLBC was found to be better than CPS in diagnosis of precursor lesions. It provided better morphology with increased detection of abnormalities and preservation of specimen for cell block and ancillary studies like immunocytochemistry and HPV detection. Therefore, it can be used as alternative strategy for cervical cancer prevention in limited resource settings.

Comparison of Computed Diffusion-Weighted Imaging b2000 and Acquired Diffusion-Weighted Imaging b2000 for Detection of Prostate Cancer (전립선암 발견을 위한 계산형 확산강조영상 b2000과 실제 획득한 b2000 영상의 비교)

  • Yeon Jung Kim;Seung Ho Kim;Tae Wook Baek;Hyungin Park;Yun-jung Lim;Hyun Kyung Jung;Joo Yeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1059-1070
    • /
    • 2022
  • Purpose To compare the sensitivity of tumor detection and inter-observer agreement between acquired diffusion-weighted imaging (aDWI) b2000 and computed DWI (cDWI) b2000 in patients with prostate cancer (PCa). Materials and Methods Eighty-eight patients diagnosed with PCa by radical prostatectomy and having undergone pre-operative 3 Tesla-MRI, including DWI (b, 0, 100, 1000, 2000 s/mm2), were included in the study. cDWI b2000 was obtained from aDWI b0, b100, and b1000. Two independent reviewers performed a review of the aDWI b2000 and cDWI b2000 images in random order at 4-week intervals. A region of interest was drawn for the largest tumor on each dataset, and a Prostate Imaging-Reporting and Data System (PI-RADS) score based on PI-RADS v2.1 was recorded. Histologic topographic maps served as the reference standard. Results The study population's Gleason scores were 6 (n = 16), 7 (n = 53), 8 (n = 9), and 9 (n = 10). According to the reviewers, the sensitivities of cDWI b2000 and aDWI b2000 showed no significant differences (for reviewer 1, both 94% [83/88]; for reviewer 2, both 90% [79/88]; p = 1.000, respectively). The kappa values of cDWI b2000 and aDWI b2000 for the PI-RADS score were 0.422 (95% confidence interval [CI], 0.240-0.603) and 0.495 (95% CI, 0.308-0.683), respectively. Conclusion cDWI b2000 showed comparable sensitivity with aDWI b2000, in addition to sustained moderate inter-observer agreement, in the detection of PCa.

Determination of the complex refractive index of $Ge_2Sb_2Te_5$ using spectroscopic ellipsometry (분광타원해석법을 이용한 $Ge_2Sb_2Te_5$ 의 복소굴절율 결정)

  • Kim, S. J.;Kim, S. Y.;Seo, H.;Park, J. W.;Chung, T. H.
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.445-449
    • /
    • 1997
  • The complex refractive indices of $Ge_2Se_2Te_5$ which show reversible phase change between the crystalline phase and an amorphous one depending upon the annealing process have been determined in the spectral range of 0.7-4.5 eV. The $Ge_2Se_2Te_5$ films were DC sputter deposited on the crystalline silicon substrate. The spectro-ellipsometry data of a thick film were analyzed following the modelling procedure where the quantum mechanical dispersion relation were used for the complex refractive indices of both the cryastalline phase $Ge_2Se_2Te_5$ and and amorphous phase $Ge_2Se_2Te_5$, respectively. On the other hand, with the surface micro-roughness layer whose effective thickness was determined from AFM analysis, the spectro-ellipsometry data were numerically inverted to yield the complex refractive index of $Ge_2Se_2Te_5$ at each wavelength. With these set of complex refractive indices, the reflectance spectra were calculated and those spectra obtained from the numerical inversion showed better agreement with the experimental reflection spectra for both the cryastalline phase and an amorphous phase. Finally, the thin $Ge_2Se_2Te_5$ film which has the optimum thickness of 26 nm as the medium for optical recording was also analyzed and the quantitative result of the film thickness and the surface microroughness has been reported.

  • PDF