• Title/Summary/Keyword: S-V agreement

Search Result 234, Processing Time 0.027 seconds

Radiation Shielding Analysis for the X-ray Facility (X-선 발생장치 시설의 방사선 차폐 해석)

  • Kwon, Seog-Guen;Choi, Ho-Sin;Moon, Philip-S.;Yook, Jong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.34-39
    • /
    • 1987
  • Radiation shielding analysis for a 6MeV X-ray facility was carried out. The primary and leakage radiation for the facility can be evaluated based on the methodology in NCRP No. 49 and 51. The present study deals with radiation scattering analysis for the outside and inside door of the facility based on the albedo concept. The calculated dose rates were compared with the results of MORSE-CG code calculation and the measured data, resulting in a good agreement, even though there existed some deviation for the inside door. These results can be utilized to the radiation shielding design of the medical and industrial X and gamma ray facilities, and to the safety evaluation of these facilities.

  • PDF

An Applicable Method of an Electromagnetic Wave Absorber for SAR Reduction in the Human Head Exposed to Electromagnetic Fields Radiated by a Cellular Phone (휴대폰 전자파에 노출된 두부내 SAR 저감을 위한 전자파 흡수체 적용 방법 연구)

  • 이윤경;백락준;홍진옥;육재림;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.884-890
    • /
    • 2003
  • In order to reduce the specific absorption rate(SAR) in a human head exposed to electromagnetic fields radiated by a cellular phone, we have analyzed an electromagnetic wave absorber attached to the handset. A manufactured electromagnetic wave absorber was composed of Mn - Zn, which had complex relative permittivity of 7.30-j0.05 and permeability of 2.20-i1.55. The SAR value from the electromagnetic wave absorber attachment was calculated by using the nonuniform finite difference time domain(FDTD) algorithm and measured by phantom model at 835 MHz. The SAR reduction due to the electromagnetic wave absorber are about 18 % at 835 MHz. The V.S.W.R and radiation pattern of antenna are good agreement with the normal antenna. The gain reduction due to the electromagnetic wave absorber are only 0.3 dB at 835 MHz. But the sensitivity of cellular phone generally improves about 1 dB.

Influence of Phenobarbital on the Hepatic Clearance of Organic Anionic Drugs in Rats - On the Basis of Pharmacokinetics of Indocyanine Green - (Rat에 있어서 Phenobarbital이 유기음이온성 의약품의 간클리어란스에 미치는 영향 - Indocyanine Green의 체내동태를 중심으로 -)

  • Lee, Yong-Bok;Shin, Sang-Chul;Koh, Ik-Bae
    • Korean Journal of Clinical Pharmacy
    • /
    • v.3 no.1
    • /
    • pp.31-43
    • /
    • 1993
  • The influence of phenobarbital(PB) pretreatment(75mg/kg/day, Lp. for 4 days) on the hepatic clearance of indocyanine green(ICG) as a model compound of organic anionic drugs was investigated in rats in order to elucidate the relative contributions of change in the hepatic blood flow versus increase in the hepatic intrinsic activity to remove ICG due to PB pretreatment. ICG(1mg/kg) was injected single bolus via femoral or portal vein to the control and the PB-pretreated rats. The initial hepatic uptake clearance$(V_{d.c.}K_{12})$ obtained from plasma concentration-time data was increased by $38.4\% in the PB-pretreated rats, which may be due to the increased hepatic blood flow by PB pretreatment. Using a pharmacokinetic approach, hepatic blood flows were estimated of 67.5ml/min/kg in control rats and 91.9ml/min/kg in PB-pretreated rats. They were in good agreement with other's blood flow estimates observed experimentally. It may be concluded that the $38\%$ increased initial hepatic uptake clearance of ICG was due to the $36\%$ increased hepatic blood flow with phenobarbital, and that the increased hepatic blood flow and the activated hepatic intrinsic clearance with phenobarbital contributed to $49\%\;and\;51\%$ of the increased systemic clearance of ICG, respectively.

  • PDF

Building frame - pile foundation - soil interaction analysis: a parametric study

  • Chore, H.S.;Ingle, R.K.;Sawant, V.A.
    • Interaction and multiscale mechanics
    • /
    • v.3 no.1
    • /
    • pp.55-79
    • /
    • 2010
  • The effect of soil-structure interaction on a single-storey, two-bay space frame resting on a pile group embedded in the cohesive soil (clay) with flexible cap is examined in this paper. For this purpose, a more rational approach is resorted to using the finite element analysis with realistic assumptions. Initially, a 3-D FEA is carried out independently for the frame on the premise of fixed column bases in which members of the superstructure are discretized using the 20-node isoparametric continuum elements. Later, a model is worked out separately for the pile foundation, by using the beam elements, plate elements and spring elements to model the pile, pile cap and soil, respectively. The stiffness obtained for the foundation is used in the interaction analysis of the frame to quantify the effect of soil-structure interaction on the response of the superstructure. In the parametric study using the substructure approach (uncoupled analysis), the effects of pile spacing, pile configuration, and pile diameter of the pile group on the response of superstructure are evaluated. The responses of the superstructure considered include the displacement at top of the frame and moments in the columns. The effect of soil-structure interaction is found to be quite significant for the type of foundation considered in the study. Fair agreement is observed between the results obtained herein using the simplified models for the pile foundation and those existing in the literature based on a complete three dimensional analysis of the building frame - pile foundation - soil system.

Importance of a rigorous evaluation of the cracking moment in RC beams and slabs

  • Lopes, A.V.;Lopes, S.M.R.
    • Computers and Concrete
    • /
    • v.9 no.4
    • /
    • pp.275-291
    • /
    • 2012
  • The service loads are often decisive in the design of concrete structures. The evaluation of the cracking moment, $M_{cr}$, is an important issue to predict the performance of the structure, such as, the deflections of the reinforced concrete beams and slabs. To neglect the steel bars of the section is a simplification that is normally used in the computation of the cracking moment. Such simplification leads to small errors in the value of this moment (typically less than 20%). However, these small errors can conduce to significant errors when the values of deflections need to be computed from $M_{cr}$. The article shows that an error of 10% on the evaluation of $M_{cr}$ can lead to errors over 100% in the deformation values. When the deformation of the structure is the decisive design parameter, the exact computing of the cracking moment is obviously very important. Such rigorous computing might lead to important savings in the cost of the structure. With this article the authors wish to draw the attention of the technical community to this fact. A simple equation to evaluate the cracking moment, $M_{cr}$, is proposed for a rectangular cross-section. This equation leads to cracking moments higher than those obtained by neglecting the reinforcement bars and is a simple rule that can be included in Eurocode 2. To verify the accuracy of the developed model, the results of the proposed equation was compared with a rigorous computational procedure. The proposed equation corresponds to a good agreement when compared with the previous approach and, therefore, this model can be used as a practical aid for calculating an accurate value of the cracking moment.

Adsorption Mechanism of Alkyl Ketones on Cation Supported by Layer Silicate. Link Formation of Hydroxyl Group (Layer Silicate에 지지된 양이온상에서 일어나는 Alkyl Ketones의 흡착기구. 水酸基의 Link 形成理論)

  • Jong Taik Kim;Jong Rack Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.4
    • /
    • pp.247-255
    • /
    • 1973
  • The self supported film specimen of Wyoming montmorillonite as a layer silicate saturated by cations,$Li^{+},\;Na^{+},\;K^{+},\;Ca^{2+},\;Ni^{2+},\;Al^{3+}$and$F^{3+}$ were allowed to contact acetone, methyl-ethyl ketone and diethyl ketone within the heatable gas cell. The i.r. spectra between $4000{\sim}1200cm^{-1}$ at different pressures of adsorbates indicated bond formation through carbonyl oxygen. Two types of carbonyl bond shift with maxima at $1713cm^{-1}$ and $1690cm^{-1}$ are attributed as coordinate bond formation of carbonyl with either surface hydroxyl or cationic hydroxyl group. The intensity of the vOH was analyzed and resonance form of cationic hydroxyl was proposed as an adsorption site. The tendency to form coordinate bond was in good agreement with calculated formal charge of carbonyl oxygen in an increasing order, acetone < methyl-ethyl ketone < diethyl ketone. As an additional mechanism of adsorption, weak hydrogen bonding of methyl hydrogen with surface oxygen was observed.

  • PDF

PILOT INJECTION OF DME FOR IGNITION OF NATURAL GAS AT DUAL FUEL ENGINE-LIKE CONDITIONS

  • MORSY M. H.;AHN D. H.;CHUNG S. H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • The ignition delay of a dual fuel system has been numerically investigated by adopting a constant volume chamber as a model problem simulating diesel engine relevant conditions. A detailed chemical kinetic mechanism, consisting of 28 species and 135 elementary reactions, of dimethyl ether (DME) with methane ($CH_{4}$) sub-mechanism has been used in conjunction with the multi-dimensional reactive flow KIVA-3V code to simulate the autoignition process. The start of ignition was defined as the moment when the maximum temperature in the combustion vessel reached to 1900 K with which a best agreement with existing experiment was achieved. Ignition delays of liquid DME injected into air at various high pressures and temperatures compared well with the existing experimental results in a combustion bomb. When a small quantity of liquid DME was injected into premixtures of $CH_{4}$/air, the ignition delay times of the dual fuel system are longer than that observed with DME only, especially at higher initial temperatures. The variation in the ignition delay between DME only and dual fuel case tend to be constant for lower initial temperatures. It was also found that the predicted values of the ignition delay in dual fuel operation are dependent on the concentration of the gaseous $CH_{4}$ in the chamber charge and less dependent on the injected mass of DME. Temperature and equivalence ratio contours of the combustion process showed that the ignition commonly starts in the boundary at which near stoichiometric mixtures could exists. Parametric studies are also conducted to show the effect of additive such as hydrogen peroxide in the ignition delay. Apart from accurate predictions of ignition delay, the coupling between multi-dimensional flow and multi-step chemistry is essential to reveal detailed features of the ignition process.

Fabrication and dielectric properties of $LaAlO_3-BaZrO_3$ perovskites ($LaAlO_3-BaZrO_3$계 perovskites의 제조 및 유전특성)

  • Lee, So-Hee;Kim, Shin;Shin, Hyun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.325-325
    • /
    • 2007
  • The perovskites in the $LaAlO_3-BaZrO_3$ system (i.e., $(1-x)LaAlO_3-xBaZrO_3$ were fabricated by a solid state reaction and their dielectric properties were investigated. For the compositions of x=0.1~0.9, the mixture of $LaAlO_3$ with a rhombohedral structure and $BaZrO_3$ with a cubic was observed when the sintering was conducted at $1500^{\circ}C$, indicating that the solubility of constituent elements was very low and a narrow solid solution region might exist. The large difference of ionic radii between $La^{3+}$ ion (0.136nm, C.N.=12) and $Ba^{2+}$ ion (0.161nm) or $Al^{3+}$ ion (0.0535nm, C.N.=6) and $Zr^{4+}$ ion (0.072nm) might hinder the mutual substitution. Within the compositions of x=0~0.7, the dielectric constant of the mixture increased with the amount of $BaZrO_3$, i.e., x value, which was in good agreement with the logarithmic mixing rule (In $_{r,i}={\Sigma}v_iln\;_{r,i}$). The increase in $BaZrO_3$ doping decreased $Q{\times}f$ value significantly due to the low $Q{\times}f$ value of $BaZrO_3$ itself, a poor microstructure of the mixture with an increased grain boundary area per volume, and defects in the cation and oxygen sub-lattices which were respectively caused by the evaporation of barium during the sintering process and the substitution of Ba on La-site or Al on Zr-site.

  • PDF

Quantitative Measurement of Laryngeal Electromyography Using Motor Unit Action Potential in Unilateral Vocal Cord Paralysis (일측성 성대 마비에서 운동단위 활동전위를 이용한 정량적 후두 근전도 분석)

  • Ha, Ryun;Kim, Dong Young;Kim, Dong Hyun;Woo, Joo Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2019
  • Background and Objectives : Laryngeal electromyography (LEMG) is valuable to evaluate the innervation status of the laryngeal muscles and the prognosis of vocal fold paralysis (VFP). However, there is a lack of agreement on quantitative interpretation of LEMG. The aim of this study is to measure the motor unit action potentials (MUAP) quantitatively in order to find cut-off values of amplitude, duration, phase for unilateral vocal fold paralysis patients. Materials and Method : Retrospective chart review was performed for the unilateral VFP patients who underwent LEMG from March 2016 to May 2018. Patient's demography, cause of VFP, vocal cord mobility, and LEMG finding were analyzed. The difference between normal and paralyzed vocal folds and cut-off values of duration, amplitude, and phase in MUAP were evaluated. Results : Thirty-six patients were enrolled in this study. Paralyzed vocal fold had significantly longer duration (p=0.021), lower amplitude (p=0.000), and smaller phase (p=0.012) than the normal. The cut-off values of duration, amplitude, and phase in MUAP for unilateral VFP were 5.15 ms, $68.35{\mu}V$, and 1.85 respectively. Conclusion : An analysis of MUAP successfully provided quantitative differences between normal and paralyzed vocal folds. But, additional research is needed to get more available cut-off value which is helpful to evaluate the status of laryngeal innervations.

Prediction of fatigue crack initiation life in SA312 Type 304LN austenitic stainless steel straight pipes with notch

  • Murthy, A. Ramachandra;Vishnuvardhan, S.;Anjusha, K.V.;Gandhi, P.;Singh, P.K.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1588-1596
    • /
    • 2022
  • In the nuclear power plants, stainless steel is widely used for fabrication of various components such as piping and pipe fittings. These piping components are subjected to cyclic loading due to start up and shut down of the nuclear power plants. The application of cyclic loading may lead to initiation of crack at stress raiser locations such as nozzle to piping connection, crown of piping bends etc. of the piping system. Crack initiation can also take place from the flaws which have gone unnoticed during manufacturing. Therefore, prediction of crack initiation life would help in decision making with respect to plant operational life. The primary objective of the present study is to compile various analytical models to predict the crack initiation life of the pipes with notch. Here notch simulates the stress raisers in the piping system. As a part of the study, Coffin-Manson equations have been benchmarked to predict the crack initiation life of pipe with notch. Analytical models proposed by Zheng et al. [1], Singh et al. [2], Yang Dong et al. [25], Masayuki et al. [33] and Liu et al. [3] were compiled to predict the crack initiation life of SA312 Type 304LN stainless steel pipe with notch under fatigue loading. Tensile and low cycle fatigue properties were evaluated for the same lot of SA312 Type 304LN stainless steel as that of pipe test. The predicted crack initiation lives by different models were compared with the experimental results of three pipes under different frequencies and loading conditions. It was observed that the predicted crack initiation life is in very good agreement with experimental results with maximum difference of ±10.0%.