• Title/Summary/Keyword: S-V agreement

Search Result 241, Processing Time 0.027 seconds

BEPU analysis of a CANDU LBLOCA RD-14M experiment using RELAP/SCDAPSIM

  • A.K. Trivedi;D.R. Novog
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1448-1459
    • /
    • 2023
  • A key element of the safety analysis is Loss of Coolant Analysis (LOCA) which must be performed using system thermal-hydraulic codes. These codes are extensively validated against separate effect and integral experiments. RELAP/SCDAPSIM is one such code that may be used to predict LBLOCA response in a CANDU reactor. The RD-14M experiment selected for the Best Estimate Plus Uncertainty study is a 44 mm (22.7%) inlet header break test with no Emergency Coolant Injection. This work has two objectives first is to simulate pipe break with RELAP and compare these results to those available from experiment and from comparable TRACE calculations. The second objective is to quantify uncertainty in the fuel element sheath (FES) temperature arising from model coefficient as well as input parameter uncertainties using Integrated Uncertainty Analysis package. RELAP calculated results are found to be in good agreement with those of TRACE and with those of experiments. The base case maximum FES temperature is 335.5 ℃ while that of 95% confidence 95th percentile is 407.41 ℃ for the first order Wilk's formula. The experimental measurements fall within the predicted band and the trends and sensitivities are similar to those reported for the TRACE code.

Determination of buildup factors for some human tissues using both MCNP5 and Phy-X / PSD

  • Mohammad M. Alda'ajeh;J.M. Sharaf;H.H. Saleh;Mefleh S. Hamideen
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4426-4430
    • /
    • 2023
  • In this article, Exposure Buildup Factor(EBF) and the Energy Absorption Buildup Factor(EABF) have been determined for blood, brain, and muscle using the Monte Carlo method which is represented by MCNP5 codes and compared with geometric progression(G-P) fitting method which is represented by Phy-X/PSD online platform. The novelty of the present work is used an energy source of less than 0.1 MeV to determine buildup factors using MCNP5 and using Phy-X/PSD for some human tissues. thus, the energy range used in this case study was 0.06-3 MeV for penetration depths covered 0.5-3 MFP. Results of MCNP5 and Phy-X/PSD are validated against reference values of water that were reported at ANS-6.4.3. present results of EABFs and EBFs for the previously mentioned human tissues appeared good agreement between MCNP5 in comparison with Phy-X/PSD, whereas, the maximum average relative deviation did not exceed 2.37%. results of our article can be used in different medical applications, such as brachytherapy, radiotherapy, and diagnostics.

Syphilis Screening Among some Industrial Workers in Korea

  • Yum, Yong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.11 no.1
    • /
    • pp.110-122
    • /
    • 1978
  • A study on the morbidity of syphilis among 729 workers in Po Hang and Ul San Industiral Complexes at the routine periodical examination was performed. In addition to the morbidity, factors related to the disease infection such as educational level, religion, preventive measures taken by the workers, history of urethritis, and so on were studied and analysed to check significant relation. The results were as follows: 1. VDRL and RPR tests were undertaken to determine the sensitivity and specificity of RPR test which was utilized for all the workers studied. It revealed 86.4% of sensitivity and 87.7% of specificity from RPR test, and 81.8% of sensitivity and 90.1% of specificity from the VDRL test compared with RPCF test. There were 87.4% of agreement rate between RPR and VDRL. Actually, RPR was more sensitive but less specific than VDRL, and found to be a satisfactory screening test for syphilis especially in the fields. 2. Among the workers in Po Hang Area 24.0% of them revealed reactive result, and in Ul San Area 5.2% revealed reactive result showing 4.6 times of risk among workers in Po Hang Area. 3. There were no statistically significant differences between RPR reactive rates and personal characteristics such as educational level, religion, history of urethritis experience, history of coitus with prostitute, and preventive measures of V.D. taken by workers if evaluated by area of Po Hang and Ul Srn separately. 4. V.D. could be encountered as an occupational disease in certain conditions of working places and the psychosocial problems of workers. And so, it is necessary that all the workers working in special estates such as in Po Hang Industrial Complex should be checked to be screened out by RPR test at periodical examinations and part of pre-employment examination also should include RPR test to be compared with. Regardless of the workmen's compensation, establishment of V.D. treatment clinic or system for such industrial workers is urgently needed. Health education regarding V.D. is another subject to be performed.

  • PDF

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors

  • Kwon, Seog-Guen;Kim, Kyung-Eung;Ha, Chung-Woo;Moon, Philip S.;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.171-179
    • /
    • 1980
  • This paper presentss flux-to-dose conversion factors for neutrons and gamma-rays based on the concept of the maximum absorbed dose. Neutron flux-to-does-rate conversion factors for energies from 2.5$\times$10$^{-8}$ to 20 MeV are presented while the conversion factors for gamma-rays are given in the energy range of 0.01 to 15MeV. Flux-to-does-rate conversion factors, which were calculated under the assumption that the radiation energy distribution has nonlinearity in phantom, are different from those values obtained by monoenergetic radiation. Especially, these values obtained here were determined for the cross section libray such as DLC-23, DLC-27, and DLC-31. The flux-to-dose-rate conversion factors obtained in this work are in a good agreement with the values presented by American National Standard Institute (ANSI) N666. These results are used to calculate the dose rate distribution of neutron and gamma-ray in any radiation fields, and will be useful for the radiation shielding analysis, radiation protection and radiation dosimetry concerned with problems of continuous energy distribution.

  • PDF

A U.S. Courts Case Study on Arbitration Clause and Class Arbitration Among Consumers (소비자중재조항과 집단중재(Class Arbitration)에 관한 미국법원의 판결동향)

  • Han, Na-Hee;Ha, Choong-Lyong;Kang, Ye-Rim
    • Journal of Arbitration Studies
    • /
    • v.28 no.2
    • /
    • pp.91-110
    • /
    • 2018
  • Consumers repeatedly make small sum purchases through business-to-consumer contracts, usually without incident. Consumer areas have been increasing; therefore, consumer disputes have been occurring frequently as well. In international consumer transactions, it is not easy to solve consumer disputes by applying the laws of different countries. Resolving disputes by using the consumer arbitration system can be a measure to protect consumers. In the U.S., a class arbitration is being operated as a mixed dispute resolution system of class action and arbitration. Consumer Arbitration has long been a controversial issue in the U.S. It is therefore a lesson for us to examine related cases. A recent U.S. Supreme Court decision, DIRECTV v. Imburgia, was looked into and after a summary of the facts, issues, and opinions and opposing opinions that had a tight controversy, a close analysis was done. The analysis through this judgment is as follows: first, the contraction of consumer protection; second, the expansion of the Federal Arbitration Act scope; third, the class arbitration's restriction; and fourth, the submission of the arbitration fairness act.

Design and Fabrication of the Triple Band(DCS, PCS, UPCS) Internal Chip Antenna (내장형 트리플(DCS, PCS, UPCS) 칩 안테나 설계 및 제작)

  • Park, Seong-Il;Park, Sung-Ha;Ko, Young-Hyuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1261-1266
    • /
    • 2009
  • In this paper, triple band mobile chip antenna for DCS(1.71${\sim}$1.88GHz) / PCS(1.75${\sim}$1.87GHz) / UPCS(1.8S${\sim}$1.99GHz) on PCB Layout is designed. To analyze the characteristics of the designed antenna, we used commerical simulation tool(HFSS). Triple and wide band characteristic could be realized the measured bandwidth(V.S.W.R<2.0) of the designed antenna operated in 1.71GHz${\sim}$1.99GHz. The size of the designed antenna is about 19mm${\times}$4mm${\times}$1.6mm, narrow bandwidth which is a defect of chip antenna is improved. And its experimental results were a good agreement with simulation performance.

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

BVR PHOTOMETRY OF SUPERGIANT STARS IN HOLMBERG II

  • Sohn Y.J.;Chang S.W.;Kim D.Y.;Kim J.W.;Kim S.H.;Lee J.E.;Lee J.G.;Lee J.M.;Lee M.Y.;Lee S.Y.;Lee U.S.;Park B.K.;Park H.E.
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • We report the photometric properties in BVR bands for the resolved bright supergiant stars in the dwarf galaxy Holmberg II. The color-magnitude diagrams and color-color diagram of 374 resolved stars indicate that the majority of the member stars are supergiant stars with a wide range of spectral type between B-K. A comparison with theoretical evolutionary tracks indicates that the supergiant stars in the observed field have progenitor masses between ${\sim}10M_{\bigodot}\;and\;20M_{\bigodot}$. The exponent of luminosity function in V is in good agreement with those of the Small and Large Magellanic Clouds.

The recombination velocity at III-V compound heterojunctions with applications to Al/$_x$/Ga/$_1-x$/As-GaAs/$_1-y$/Sb/$_y$/ solar cells

  • 김정순
    • 전기의세계
    • /
    • v.28 no.4
    • /
    • pp.53-63
    • /
    • 1979
  • Interface recombination velocity in $Al_{x}$G $a_{1-x}$ As-GaAs and $Al_{0.85}$, G $a_{0.15}$ As-GaA $s_{1-y}$S $b_{y}$ heterojunction systems is studied as a function of lattice mismatch. The results are applied to the design of highly efficient III-V heterojunction solar cells. A horizontal liquid-phase epitaxial growth system was used to prepare p-p-p and p-p-n $Al_{x}$G $a_{1-x}$ As-GaA $s_{1-y}$S $b_{y}$-A $l_{x}$G $a_{1-x}$ As double heterojunction test samples with specified values of x and y. Samples were grown at each composition, with different GaAs and GaAs Sb layer thicknesses. A method was developed to obtain the lattice mismatch and lattice constants in mixed single crystals grown on (100) and (111)B oriented GaAs substrates. In the AlGaAs system, elastic lattice deformation with effective Poisson ratios .mu.$_{eff}$ (100=0.312 and .mu.$_{eff}$ (111B) =0.190 was observed. The lattice constant $a_{0}$ (A $l_{x}$G $a_{1-x}$ As)=5.6532+0.0084x.angs. was obtained at 300K which is in good Agreement with Vegard's law. In the GaAsSb system, although elastic lattice deformation was observed in (111) B-oriented crystals, misfit dislocations reduced the Poisson ratio to zero in (100)-oriented samples. When $a_{0}$ (GaSb)=6.0959 .angs. was assumed at 300K, both (100) and (111)B oriented GaAsSb layers deviated only slightly from Vegard's law. Both (100) and (111)B zero-mismatch $Al_{0.85}$ G $a_{0.15}$As-GaA $s_{1-y}$S $b_{y}$ layers were grown from melts with a weight ratio of $W_{sb}$ / $W_{Ga}$ =0.13 and a growth temperature of 840 to 820 .deg.C. The corresponding Sb compositions were y=0.015 and 0.024 on (100) and (111)B orientations, respectively. This occurs because of a fortuitous in the Sb distribution coefficient with orientation. Interface recombination velocity was estimated from the dependence of the effective minority carrier lifetime on double-heterojunction spacing, using either optical phase-shift or electroluminescence timedecay techniques. The recombination velocity at a (100) interface was reduced from (2 to 3)*10$^{4}$ for y=0 to (6 to 7)*10$^{3}$ cm/sec for lattice-matched $Al_{0.85}$G $a_{0.15}$As-GaA $s_{0.985}$S $b_{0.015}$ Although this reduction is slightly less than that expected from the exponential relationship between interface recombination velocity and lattice mismatch as found in the AlGaAs-GaAs system, solar cells constructed from such a combination of materials should have an excellent spectral response to photons with energies over the full range from 1.4 to 2.6 eV. Similar measurements on a (111) B oriented lattice-matched heterojunction produced some-what larger interface recombination velocities.ities.ities.s.

  • PDF

Symmetric and Asymmetric Double Gate MOSFET Modeling

  • Abebe, H.;Cumberbatch, E.;Morris, H.;Tyree, V.;Numata, T.; Uno, S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.4
    • /
    • pp.225-232
    • /
    • 2009
  • An analytical compact model for the asymmetric lightly doped Double Gate (DG) MOSFET is presented. The model is developed using the Lambert Function and a 2-dimensional (2-D) parabolic electrostatic potential approximation. Compact models of the net charge and channel current of the DG-MOSFET are derived in section 2. Results for the channel potential and current are compared with 2-D numerical data for a lightly doped DG MOSFET in section 3, showing very good agreement.