• Title/Summary/Keyword: S-STEP

Search Result 6,426, Processing Time 0.033 seconds

A Study on the Fitness of Children's Shoes -Centered on the Correlation of Shoes Size and Walking- (아동화의 적합성에 관한 연구 -신발크기와 보행과의 관계를 중심으로-)

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.3
    • /
    • pp.23-34
    • /
    • 1991
  • With 10 subjects of 6-year-old children residing in Pusan, I analyzed the relation of walking types(step angle, step width, step and stride) and wear comfort according to the style and size fo shoes in order to reveal the fitness of children's shoes centered on the relationship of shoes size and walking. Three styles of children's shoes(laced and unlaced formal shoes, magic-taped sports shoes) ranging in five different size were used. The following are conclusions. 1. As to step angle, there was no conceivable change in the left side, while the right side had a significance in accordance with the shoes size at p<0.001. As the size grew, right step angle of all shoes increased, with unlaced shoes having more influence than others. Step angle were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 2. As to step width, there was no conceivable change in the style of shoes, while shoes size had a significance at p<0.001. As the size grew, step width also increased. Step width were the smallest when all the sampled shoes made the difference of 5mm between foot size and shoes size. 3. Step and stride, however, took no significance at all, since they were not influenced by the size or style of the shoes. 4. Wear comfort had a significance at the level of p<0.001. Since it was influenced by the size or style of the shoes. The best wear comfort was felt when all the sampled shoes had laces and magic tapes as well as the size with the difference of 5-10mm between foot size and shoes size.

  • PDF

Step Response Characteristics of Shunts for Impulse Current (충격전류용 shunt의 직각파 특성)

  • Kim, I.S.;Kim, M.K.;Huh, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1445_1446
    • /
    • 2009
  • This paper represents the step response characteristics of shunts for impulse current. This work is aimed at the development of the reference measuring system(RMS) for impulse current rated 10 kA at 1/$20{\mu}s$, 100 kA at 4/$10{\mu}s$, 20 kA at 8/$20{\mu}s$, 40 kA at 30/$80{\mu}s$. According to the IEC 60060-2, the step response characteristics was assessed. As results of the test, the step response characteristics of newly developed shunts for impulse current satisfied requirements of RMS.

  • PDF

A Study of Informational Strategy Character of hospital Administration (병원행정의 정보화 전략특성에 관한 연구)

  • Kim Tae-Seong
    • Management & Information Systems Review
    • /
    • v.1
    • /
    • pp.413-443
    • /
    • 1997
  • In today's hospital-management, information system and the information by it will be a necessary administrative materials of organization with man-power, funds, equipment and resources. This study is for figuring out steps to utilize information-system, an important strategy to grow the hospital applying to the change of surroundings, improving the service for patients, accelerating medical examination, improving it in quality and suggesting a basis be able to manage it effectively by putting information system in practice such as economic effect by shorting time and the effect of medical study by computerizing clinical data. And the result of it is as follows: From the Nolan's 6 step - model about the degree using information system in hospital-management, the 1st group of hospital-size came to 1st and 2nd step, the 2nd group to the 3rd and 4th step and the 3rd group to the 5th and 6th step, which correspond to the survey- results that information system increases with the size of the hospital to propagation, regulation and integration step and that the number of the hospital developing to the step managing information is increasing.

  • PDF

Electrical Characteristics of Self Aligned Gate GaAs MESFETs Using Ion Beam Deposited Tungsten (이온빔 증착 텅스텐을 이용한 자기정렬 게이트 GaAs MESFET의 전기적 특성)

  • 편광의;박형무;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1841-1851
    • /
    • 1990
  • Self-aligned gate GaAs MESFETs using ion beam deposited tungsten applicable to GaAs LSI fabrication process have been fabricated. Silicon implanted samples were annealed using isothermla two step RTA process and conventional one step RTA process. The electrical and physicla characteristics of annealed samples were investigated using Hall and I-V measurements. As results of measurements, activation characteristics of the isothermal two step RTA process are better than those of one step annealed ones. Using the developed processes, GaAs SAFETs (Self-Aligned Gate FET) have been fabricated and electdrical characteirstics are measured. As results, subthreshold currents of SAGFETs are 6x10**-10 A/\ulcorner, that is compatible to conventional MESFET, maximum transconductances of 0.75\ulcorner gate MESFET using one step RTA process and 2\ulcorner gate MESFET using isothermal two step RTA process are 18 mS/mm, 41 mS/mm respectively.

  • PDF

The Influence of Step Length at Different Walking Speed on the Moment of the Lower Limb Joint (보행속도에 따른 보폭변화가 하지관절 모멘트에 미치는 영향)

  • Kim, Ro-Bin;Jin, Young-Wan;Moon, Gon-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • The purpose of this study was to examine the effect of step length on the joint moment. The subjects were 4 undergraduate and graduate students in their 20s with normal legs. The subjects were individually tested by the running timer at the walking speed of 0.67m/s, 134m/s, and 2.46m/s. The step length was regulated to -10% of normal, normal and +10% of normal step length using foot print. The walking performances of each subjects were filmed using a high speed video camera. The raw data were analyzed by LabVIEW Graphical Program and these data were analyzed by ANOVAs and Scheffe. The results of this study were as follows: The maximum dorsiflexion moment of the ankle joint increased as the step length increased only at the fast walking speed. Although there wasn't significant difference shown in the plantar flexion moment, regular pattern in the plantar flexion moment which increased as the step length increased was found. The first maximum extension moment of the knee joint increased only at the normal walking speed, but there appeared no significant difference in the maximum flexion and second extension moment. The maximum extension moment of the hip joint increased at the normal and fast walking speed. Although there wasn't significant difference, regular pattern in flexion moment which increased as the step length increased was found.

A Dynamic QoS Adjustment Enabled and Load-balancing-aware Service Composition Method for Multiple Requests

  • Wu, Xiaozhu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.3
    • /
    • pp.891-910
    • /
    • 2021
  • Previous QoS-aware service composition methods mainly focus on how to generate composite service with the optimal QoS efficiently for a single request. However, in the real application scenarios, there are multiple service requests and multiple service providers. It is more important to compose services with suboptimal QoS and maintain the load balance between services. To solve this problem, in this paper, we propose a service composition method, named as dynamically change and balancing composition method (DCBC). It assumes that the QoS of service is not static, and the services can adjust the value of QoS to gain more opportunities to be selected for composition. The method mainly includes two steps, which are the preprocessing step and the service selection step. In the preprocessing step, a backward global best QoS calculation is performed which regarding the static and dynamic QoS respectively; then guided by the global QoS, the feasible services can be selected efficiently in the service selection step. The experiments show that the DCBC method can not only improve the overall quality of composite services but also guarantee the fulfill ratio of requests and the load balance of services.

An acoustic channel estimation using least mean fourth with an average gradient vector and a self-adjusted step size (기울기 평균 벡터를 사용한 가변 스텝 최소 평균 사승을 사용한 음향 채널 추정기)

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.156-162
    • /
    • 2018
  • The LMF (Least Mean Fourth) algorithm is well known for its fast convergence and low steady-state error especially in non-Gaussian noise environments. Recently, there has been increasing interest in the LMS (Least Mean Square) algorithms with self-adjusted step size. It is because the self-adjusted step-size LMS algorithms have shown to outperform the conventional fixed step-size LMS in the various situations. In this paper, a self-adjusted step-size LMF algorithm is proposed, which adopts an averaged gradient based step size as a self-adjusted step size. It is expected that the proposed algorithm also outperforms the conventional fixed step-size LMF. The superiority of the proposed algorithm is confirmed by the simulations in the time invariant and time variant channels.

The Determination of Initial Blank Shape by Using the One-Step FEM (One-Step FEM을 이용한 초기 블랭크 형상 결정에 관한 연구)

  • Jung, Dong-Won;Lee, Sang-Je
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.21-28
    • /
    • 1999
  • In this paper, a finite element method for the determination of initial blank shape in sheet metal forming process will be introduced. The initial blank shape is determined by the only one step from the final to the initial blank. The used finite element inverse method adopted Henky's deformation theory, Hill's anisotropic yield criterion and simplified boundary conditions. Based on this theory. a three-dimensional membrane finite element code was developed. The developed code will be applied to several sheet metal forming examples for the demonstration of its validity.

  • PDF

Enantioselective Hydrolysis of (R,S)-Naproxen Methyl Ester Using Two-step Acetone-treated Candida rugosa Lipase (2단계 아세톤 침전법으로부터 얻어진 Candida rugosa Lipase를 이용한 (R,S)-Naproxen Ester의 광학선택성 수화반응)

  • 이은교;최순자;정봉현
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.4
    • /
    • pp.223-227
    • /
    • 2000
  • A novel two-step acetone treatment method was developed to enhance the enantioselectivity of Candida rugosa lipase (CRL) toward the hydrolysis of racemic naproxen methyl ester. The acetone-teated CRL was considerably more enantioselective than the crude CRL, yielding an enantiomeric excess of 98~100%. The crude and acetone-treated CRLs were subjected to anion exchange chromatography, and their chromatography profiles were compared. In consequence, both chromatography profiles were found to be almost identical, resulting in two separate lipase peaks (lipase A and B). The lipase B, which is known to be less enantioselective, was treated with acetone using a two-step treatment method. The enantioselectivity of acetone-treated lipase B was dramatically increased, yielding an enantiomeric excess of 99%.

  • PDF