Speculation of the Correlationship between Public Health Practice, Consumption and Fatigue in Patients who Complain Fatigue (피로를 주소로 내원한 환자의 생활섭생, 허손 및 피로의 상관성에 대한 고찰)

  • Kim, Se-Hoon;Lee, Jang-Hoon;Lee, Seung-Bo;Choi, Mi-Young;Kim, Young-Chul;Woo, Hong-Jung
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.219-230
    • /
    • 2008
  • Objectives : Consumption is a chronic wasting disease, in oriental medicine concept. Fatigue is a common symptom experienced by many people who have consumption. However, there has been little study about the relationship between consumption and fatigue in the Oriental medicine. For this reason, we attempted to investigate the present status of fatigue of outpatients, and its relation with consumption index, public health practice index, Chalder fatigue scale and Subjective Symptoms of Fatigue Test. Methods : The subjects were 149 outpatients who complain fatigue between Nov. 1, 2006 and Oct. 31, 2007. We measured degree of consumption by consumption index. We measured degree of fatigue by Chalder fatigue scale and Subjective Symptoms of Fatigue Test. Public health practice were investigated by "Breslow's 7 health practice". Results : Studies have shown that a group who disregard public health practices have higher numerical value, in part of $q\grave{i}-x\bar{u}$, $xu\grave{e}-x\bar{u}$, and Physical symptoms than a group more concerned with public health practice. A group who has fatigue for a period over 6 months are more likely to be $q\grave{i}-x\bar{u}$, $y\bar{i}n-x\bar{u}$, Chalder fatigue scale, neuro-sensory symptoms than a group fatigued for less than 6 months. Among the subjects, 81 (55.5%) were considered as 'fatigue patients' by the Chalder scale. Chalder fatigue scale, according to the Subjective Symptoms of Fatigue Test, consumption also, The more increase of Subjective symptoms of fatigue test, the more of consumption scale. Conclusions : This study has shown that there is a link between consumption and fatigue. Moreover, oriental medicine's consumption is more concrete than fatigue scale, so consumption index will have wide application to the study of fatigue.

  • PDF

A Study on the Evaluation Method of Fatigue Strength of Membrane Type LNG Tank(I) (멤브레인 방식 LNG탱크의 피로강도 평가법에 관한 연구 (I))

  • 김종호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.49-58
    • /
    • 1997
  • The membrane type LNG tank is non self-supporting tank which consists of both primary and secondary membrane supported through the insulation boxes by the adjacent hull struc¬ture. Although the membranes are not structural member. They are subject to periodical cyclic loads due to the thermal expansion and other expansions or contraction of membrane. At the design stage of the tank, an analytical and experimental approach on the fatigue strengths of membrane and its welds is necessary in order to assist the designer and the inpector. In this study the evaluation method of fatigue strength of membrane type LNG tank is pre¬sented with FEM analysis and fatigue test of lap welds and it contains the following:1) The fatigue tests and preparation of design S - N curve for lap welds 2) FEM analysis of test specimens 3) Estimation of cumulative damage factor of lap welds 4) Guideline for inspection of lap welds of membrane type LNG tank As the results of analytical and experimental approaches in this study, the evaluation method of fatigue strengths of membrane type LNG tank is proposed, which is expected to be useful for design and inspection of membrane type LNG tank.

  • PDF

Fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete composite beams

  • Han, Qing-Hua;Wang, Yi-Hong;Xu, Jie;Xing, Ying
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.353-368
    • /
    • 2016
  • This paper extends our recent work on the fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete (RRFC) composite beams. A series of 16 fatigue push-out tests were conducted using a hydraulic servo testing machine. Three different recycled tyre rubber contents of concrete, 0%, 5% and 10%, were adopted as main variable parameters. Stress amplitudes and the diameters of studs were also taken into consideration in the tests. The results show that the fatigue lives of studs in 5% and 10% RRFC were 1.6 and 2.0 times greater of those in normal concrete, respectively. At the same time, the ultimate residual slips' values of stud increased in RRFC to highlight its better ductility. The average ultimate residual slip value of the studs was found to be equal to a quarter of studs' diameter. It had also been proved that stress amplitude was inversely proportional to the fatigue life of studs. Moreover, the fatigue lives of studs with large diameter were slightly shorter than those of smaller ones and using larger ones had the risk of tearing off the base metal. Finally, the comparison between test results and three national codes was discussed.

The Vibration Characteristic and Fatigue Life Estimation of a Small-scaled Hingeless Hub System with Composite Rectangular Blades (복합재료 기준형 블레이드를 장착한 축소 힌지없는 허브시스템의 진동특성과 피로수명 예측)

  • Song, Keun-Woong;Kim, Jun-Ho;Kim, Duck-Kwan;Joo, Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.310-315
    • /
    • 2003
  • This paper described that rotating test and fatigue test of a small-scale hingeless hub system with composite rectangular blades. Generally Rotating stability and fatigue test technique is one of Key-technology on test and evaluation for helicopter rotor system Rotating test of hingeless rotor system was achieved by means of rotor vibration characteristic and aeroelastic stability test GSRTS, equipped with hydraulic actuator and 6-component rotating balance was used to test hingeless rotor system especially for an observation of blade motion including flawing, lagging and feathering. Rotating test was done in hover and forward flight condition. Small-scaled blade fatigue test condition was determined by blade load analysis with the reference table of composite materials(S-N curve). Fatigue test bench was developed for the estimation of blade fatigue life, and tested its characteristic.

  • PDF

Fatigue analysis of crumble rubber concrete-steel composite beams based on XFEM

  • Han, Qing-Hua;Yang, Guang;Xu, Jie;Wang, Yi-Hong
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 2017
  • The fatigue fracture of studs is the main reason for failure of composite beams based on massive engineering practices. Hence, studying the laws of cracks initiation and propagation are of great directive significance. eXtended Finite Element Method (XFEM) is an effective method in solving moving discontinuous problems in recent years. This paper extends our recent work on the fatigue damage analysis of stud shear connectors in the steel and crumble rubber concrete (RRFC) composite beams based on XFEM. The process of crack initiation to failure of the stud is simulated and an effective calculation criteria for the fatigue life of the composite beams is put forward. After the reliability of the numerical analysis is verified based on tests results, the extensive parametric study is conducted concerning effects of different rubber contents, shear connection degrees and the stress amplitudes. Results show that with the increasing rubber contents and shear connection degrees, the fatigue lives of composite beams increase obviously. Furthermore, the relationship between the fatigue life of the stud at the edge of the shear span and the whole composite beams is studied. Finally, the S-N curves of the single stud and the whole composite beams are put forward based on XFEM.

A Study on Prediction of Fatigue Life using MFC Sensors (MFC센서를 이용한 피로수명예측에 관한 연구)

  • Lee, Ji-Hoon;Oh, Dong-Jin;Kim, Myung-Hyun
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.32-36
    • /
    • 2013
  • The large-scale structures have the possibility that there are defects such as cracks due to stress concentration caused by geometric discontinuities in the structure. In this respect, the assessment of fatigue life and the development of structural health monitoring(SHM) are very important. Fatigue design of structure is typically accomplished either using a set of stress cycle (S-N) data obtained from fatigue tests or using the fracture mechanics approach. The stress intensity factor(SIF) is required for the estimation of fatigue crack propagation life from the linear elastic fracture mechanics (LEFM) perspective. In this study, Macro Fiber Composie(MFC) sensor for the measurement of SIF of two dimensional cracks is used. The SIF based on the piezoelectric constitutive law and fracture mechanics are calculated. The measured values of the SIF are later used for the prediction of the crack propagation life. In this study, the measured value of the SIF and the fatigue life are compared with the theoretical results.

AN EXPERIMENTAL STUDY ON THE FATIGUE FRACTURE OF LAMINATE PORCELAIN (치과용 라미네이트 도재의 피로파괴에 관한 실험적 연구)

  • Park Charn-Woon;Bae Tae-Sung;Lee Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.482-505
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture characteristics and the effect of resin bonding of laminate porcelain. In order to characterize the indentation-induced crack, Young's moduli and characteristic indentation dimensions were measured. The fatigue life under three point flexure test was measured using the electro-dynamic type fatigue machine, and the crack propagation with thermocycling was investigated on the condition of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ bath. The Vickers indentation pattern and the fracture surface were examined by an optical microscope and a scanning electron microscope (SEM). The results obtained were summarized as follows ; 1. Young's moduli(E) of the laminate porcelain and the resin cement used in this experiment were $62.56{\pm}3.79GPa$ and $15.01{\pm}0.12GPa$, respectively. 2. The initial crack size of the laminate porcelain was $69.19{\pm}5.94{\mu}m$ when an indentation load of 9.8N was applied, and the fracture toughness was $1.065{\pm}0.156MPa\;m^{1/2}$. 3. The fatigue life of laminate porcelain showed the constant fracture range at the stress level 27.46-35.30MPa. 4. When a cyclic flexure load was applied, the fatigue life of resin-bonded laminate porcelain was more decreased than that of laminate porcelain. 5. When a thermocycling was conducted, the crack growth rate of resin-bonded laminate porcelain was more increased than that of laminate porcelain. 6. Fracture surface showed the radial crack, the lateral crack, and the macroscopic crack branching region beneath the plastic deformation region when an indentation load of 9.8N was applied.

  • PDF

Experiments for the Fatigue Behavior of High Strength Concrete (고강도 콘크리트의 피로거동에 관한 실험적 연구)

  • 김진근;김윤용
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 1993
  • In thls study, cylindrical concrete specimens wth varlous strength levels were tested to lnves tlgate the fatigue behavlor of high strength concrete. Selected test variables welp cornpresslve strength with 4 levels(26 MIPa, 54 MPa, 82 MPa. 103 MPa) and maximum \tress wlth 4 levels (75% 80%, 85%, 95%). A total of 160 specimens(${\phi}100{\times}200mm$) were cdsted fol the test. l'he fatigue llfe was decreased for the hlgher strength concreate. R model fol S N, relationship con sidering the effect of compressive strength, was proposed. In addition, this model included the stram rate effect whlch was modified for the strength level. It was found that the ~rrecoverable stram of normal strength concretc3 was greater than that of high strength concrete However the strain ~ncrease per cycle of load was great for the highcr strength concrete.

Effects of Vanadium Water on Cancer-related Fatigue of Non Advanced Cancer Patients: Randomized Double Blinded Controlled Trial (비진행성 암환자의 암성 피로에 대한 바나듐수의 효능: 무작위배정 이중맹검 대조군 시험)

  • Zheng, Hong-Mei;Kim, Dong-Hee;Lee, Suk-Hoon;Park, Yoo-Kyoung;Yoo, Hwa-Seung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1800-1806
    • /
    • 2010
  • This study was conducted to evaluate the efficacy and safety of vanadium water (VW) on cancer-related fatigue of non-advanced cancer patients. For the experimental group administration, participants consumed three 500 mL/bottle bottles of Jeju Island's VW, which contained 15~20 ppb of vanadium, three times a day (morning, afternoon, evening) for 4 weeks (28 days) without any additional treatments for fatigue improvement. The control group participants consumed three 500 mL/bottle bottles of ordinary water (0 ppb of vanadium) three times a day for the same period of time without any additional treatments for fatigue improvement. After 4 weeks of VW consumption, total score of Revised Piper Fatigue Scale (RPFS) was reduced 30% compared to the basal score after Fisher's Exact Test which resulted in a statistical borderline significance (p=0.0799) and result of t-test of comparison between two groups' RPFS total score and fatigue cognitive/mood changes resulted in a statistical significance (p=0.0112). In detail, only 36.4% of control group (N=11) showed improvement while 77.8% of treatment group (N=9) showed fatigue improvement. No other lab measures, including thyroid hormone level indicated any significant differences between two groups. In conclusion, daily consumption of 1.5 L of vanadium water for 4 weeks showed improvement of non-advanced cancer patients' fatigue.

Fatigue Behavior of Steel-Concrete Composite Bridge Deck with Perfobond Rib Shear Connector (유공판재형 전단연결재를 갖는 강-콘크리트 합성바닥판의 피로거동에 관한 연구)

  • Kyung, Kab Soo;Lee, Seung Yong;Jeong, Youn Ju;Kwon, Soon Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.71-80
    • /
    • 2010
  • Bridge deck is directly influenced by environment and vehicle load, it is easily damaged so that it requires an appropriate repair and retrofit. Therefore, developing a bridge deck with high durability is necessary in order to minimize the maintenance of bridge deck and use it to its design life. In this study, static test was carried out to evaluate a fatigue capacity of steel-concrete composite deck, which was newly developed by supplementing problems of existing reinforced concrete deck. Based on results from the static test, fatigue load was decided, and fatigue test was conducted under the constant amplitude repeated load. From the fatigue tests, the S-N curve regarding principle structural details of composite deck was made, and characteristics of fatigue behavior was estimated by comparing and evaluating it with fatigue design criteria. In addition, fatigue design guideline was presented. As a result, it is found that each structural details of composite deck proposed by this study, such as upper flange of corrugated steel plate and middle section of it, shear connector and lower flange of corrugated steel plate, is satisfying the fatigue strength.