• Title/Summary/Keyword: S-300 system

Search Result 950, Processing Time 0.027 seconds

Application of Mahalanobis Taguchi System for Analysis of Multivariate System (Mahalanobis Taguchi System을 이용한 다변량 시스템의 해석에 관한 연구)

  • Hong, Jeong-Eui;Kim, Yong-Beom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.11a
    • /
    • pp.300-310
    • /
    • 2005
  • Mahalanobis Taguchi System (MTS) is developed by Genishi Taguchi as a part of his quality engineering methodology. The basic idea of Taguchi's quality engineering is looking for the way of effectiveness of analyzing multivariate system. In the MTS, with the standardized variables of healthy normal data, Mahalanobis Distance(MD) calculated and that can be discriminate between normal and abnormal objects. If this discrimination process is successful, next step is optimization which is try to reduce number of attributes by neglecting less effective attributes to MD. Orthogonal Array (OA) and Signal to Noise ratio (S/N) are used to evaluate the amount contribution of each attribute to the MD. Wisconsin Breast Cancer study, from machining learning repository at University of California at Irvine, used for examining the discriminant ability of MTS.

  • PDF

A Basic Study of the Snow Melting System for the Anti-Freezing Road using the Pulsating Heat Pipe (PHP를 이용한 도로융설 시스템에 관한 기초연구)

  • Kim, J.S.;Ha, S.J.;Son, K.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.19-24
    • /
    • 2010
  • The purpose of this study is to develop a snow melting system using the pulsating heat pipe(PHP). The experimental apparatus is consisted of a PHP, a concrete structure, a constant water thermostatic bath and a flowmeter. The experiment was performed at the outdoor air temperature of $-8^{\circ}C$ and inlet temperature of hot water of $75^{\circ}C$. PHP is the closed and non-loop type heat exchanger which is charging R-410A as an operating fluid. As experimental results, the temperature profile of vertical and horizontal orientation of concrete structure was measured with operating time. The heat flux of the snow melting was required more than 300 $W/m^2$. We confirmed that the snow melting system using the PHP was useful for anti-freezing road.

Tape-Type Liquid Leakage Film Sensor (액체누설 감지용 테이프형 필름센서)

  • Yu, D.K.;Kim, K.S.;Yub, H.K.;Han, G.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • The adhesive-tape of a liquid leak film sensor including the alarm system is developed. The sensing film is composed of three layers such as base film layer, conductive line layer, and protection film layer. The thickness of film is 300~500 um, the width is 3.55 cm, and the unit length is 200 m. On the conductive line layer, three conducting lines and one resistive line are formulated by the electronic printing method with a conducting ink of silver-nano size. When a liquid leaks for the electricity to be conducted between the conductive line and the resistive line, the position of leakage is monitored by measuring the voltage varied according to the change of resistance between two lines. The error range of sensing position of 200 m film sensor is ${\pm}1m$.

Bonding process parameter optimization of flip-chip bonder (Flip-chip 본딩 장비 제작 및 공정조건 최적화)

  • Shim H.Y.;Kang H.S.;Jeong H.;Cho Y.J.;Kim W.S.;Kang S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.763-768
    • /
    • 2005
  • Bare-chip packaging becomes more popular along with the miniaturization of IT components. In this paper, we have studied flip-chip process, and developed automated bonding system. Among the several bonding method, NCP bonding is chosen and batch-type equipment is manufactured. The dual optics and vision system aligns the chip with the substrate. The bonding head equipped with temperature and force controllers bonds the chip. The system can be easily modified for other bonding methods such as ACF In bonding process, the bonding forte and temperature are known as the most dominant bonding parameters. A parametric study is performed for these two parameters. For the test sample, we used standard flip-chip test kit which consists of FR4 boards and dummy flip-chips. The bonding test was performed fur two types of flip-chips with different chip size and lead pitch. The bonding temperatures are chosen between $25^{\circ}C\;to\;300^{\circ}C$. The bonding forces are chosen between 5N and 300N. The bonding strength is checked using bonding force tester. After the bonding force test, the samples are examined by microscope to determine the failure mode. The relations between the bonding strength and the bonding parameters are analyzed and compared with bonding models. Finally, the most suitable bonding condition is suggested in terms of temperature and force.

  • PDF

Nitric oxide modulates antioxidant defense and the methylglyoxal detoxification system and reduces salinity-induced damage of wheat seedlings

  • Hasanuzzaman, Mirza;Hossain, Mohammad Anwar;Fujita, Masayuki
    • Plant Biotechnology Reports
    • /
    • v.5 no.4
    • /
    • pp.353-365
    • /
    • 2011
  • The present study investigates the possible regulatory role of exogenous nitric oxide (NO) in antioxidant defense and methylglyoxal (MG) detoxification systems of wheat seedlings exposed to salt stress (150 and 300 mM NaCl, 4 days). Seedlings were pre-treated for 24 h with 1 mM sodium nitroprusside, a NO donor, and then subjected to salt stress. The ascorbate (AsA) content decreased significantly with increased salt stress. The amount of reduced glutathione (GSH) and glutathione disulfide (GSSG) and the GSH/GSSG ratio increased with an increase in the level of salt stress. The glutathione S-transferase (GST) activity increased significantly with severe salt stress (300 mM). The ascorbate peroxidase (APX), monodehydroascorbate reductase (MDHAR), dehydroascorbate reductase (DHAR), catalase (CAT) and glutathione peroxidase (GPX) activities did not show significant changes in response to salt stress. The glutathione reductase (GR), glyoxalase I (Gly I), and glyoxalase II (Gly II) activities decreased upon the imposition of salt stress, especially at 300 mM NaCl, with a concomitant increase in the $H_2O_2$ and lipid peroxidation levels. Exogenous NO pretreatment of the seedlings had little influence on the nonenzymatic and enzymatic components compared to the seedlings of the untreated control. Further investigation revealed that NO pre-treatment had a synergistic effect; that is, the pre-treatment increased the AsA and GSH content and the GSH/GSSG ratio, as well as the activities of MDHAR, DHAR, GR, GST, GPX, Gly I, and Gly II in most of the seedlings subjected to salt stress. These results suggest that the exogenous application of NO rendered the plants more tolerant to salinity-induced oxidative damage by enhancing their antioxidant defense and MG detoxification systems.

Parametric Analysis of the Electric and Magnetic Field Waveforms Produced by Intracloud Lightning Discharges (운방전에 의해 발생한 전계와 자계 파형의 파라미터 분석)

  • Lee, Bok-Hee;Lee, Woo-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.81-88
    • /
    • 2006
  • In this study, the electric and magnetic fields measuring system were designed and fabricated to investigate the electric characteristics of lightning discharges. Frequency bandwidth of electric field measuring system ranges from 40[Hz] to 2.6[MHz] and its response characteristic is 2.1[(V/m)/mV]. Frequency bandwidth of magnetic field measuring system ranges from 300[Hz] to 1[MHz] and its response characteristic is 2.8[nT/mV]. Electric and magnetic fields due to intracloud lightning discharges were observed and their waveform parameters were statistically analyzed. As a result, waveform parameters of electric and magnetic fields are nearly independent of polarity. The mean rise times and the zero-crossing times of electric and magnetic fields are approximately $5.5[{\mu}s]\;and\;21[{\mu}s]$, respectively.

Location Estimation Algorithm with TDOA Scheme in Real Time Location System (RTLS에서 TDOA 기법을 이용한 위치추정 알고리즘)

  • Jeong, Seung-Hee;Kang, Chul-Gyu;Oh, Chang-Heon;Lim, Choon-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.459-462
    • /
    • 2005
  • In this paper, we investigate the high precision location estimation algorithm in 2.45GHz band RTLS with multiple tags. The location is estimated in LOS environments, 300m ${\times}$ 300m area, and 2D coordinates adopting a TDOA scheme which is not necessitate the transmission time of tags. We evaluate the average estimation error in distance assuming that tags are randomly distributed and the readers(3${\sim}$8) are uniformly(equal space) placed in test area. In results, average estimation error is 3.12m and 1.47m at reader numbers of 4 and 8, respectively. Minimum estimation error is obtained when the accumulated receiving signal from a tag is 3 or 4 regardless of available reader numbers. The error is less than 3m, satisfies the specification of RTLS.

  • PDF

Fluidization Study in the Fluidized Bed Drying of Naked and Husked Barley (쌀보리와 겉보리의 유동층 건조에서의 유동화 연구)

  • Kim, Hee-Yun;Hur, Jong-Hwa;Cho, Duk-Jae
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.414-422
    • /
    • 1992
  • To keep up with urgent need of continuous, effective and rapid drying unit, a fluidized bed drying system with computer controlling air temperature, velocity and relative humidity was designed. This study was attempted to determine physical properties and some basic experiments of fluidized bed d교ing of barley. Also experimental data of the designed fluidized bed drying system using the barely were compared with those of published equations to confirm the reliability of the system and the following results were obtained. The physical dimension husked barley were shown larger than that of naked barley from the experiment. When air temperature. relative humidity and charged amount were $35^{\circ}C$, 30% and 300g respectively, the minimum fluidization velocity of naked and husked barley were found 1.5 m/s and 1.7 m/s. And the optimum fluidization velocity was shown as 3.0 m/s from the experiment. The empirical equation of $U_{mf}$ in this fluidized system was obtained as follow; $U_{mf}^2= \frac{{\phi_s}\;d_p}{Hk}\;{\cdot}\;\frac{(\rho_s-\rho_g)g\;{{\varepsilon}_{mf}^3}} {\rho_g}(Re_p>1,000)$ Where HK=0.4881 for naked barley, 0.6649 for husked barley.

  • PDF

Fundamental Design of Development Facilities of Deep Ocean Water Resource at Gosung Sea (고성 해양심층수 개발시설의 기본설계 연구)

  • Kim, H.J.;Hong, S.W.;Choi, H.S.;Hong, K.Y.;Yang, C.K.;Hong, S.;Hong, S.Y.;Kim, J.H.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.83-88
    • /
    • 2003
  • Recently, deep ocean water (DOW), which is plentiful in the East sea, has been recognized a global resources for 21st century. To develop DOW resource of 300m deep at Gosung sea, the pipeline of about 4 km long is essentially required to establish land based model complex of DOWA techno-park at coastal zone. This study aims to establish design procedure of DOW supplying and utilizing systems, and to complete basic design of every major facilities. To design, various numerical analysis and engineering consideration have been studied by cooperative works for practical use.

  • PDF

Study on the Performance of the Cascade System Using Alternative Refrigerants (대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구)

  • 박종훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF