• Title/Summary/Keyword: S-대역

Search Result 1,982, Processing Time 0.03 seconds

Acoustic Characteristic of Emergency Broadcasting Speakers (비상방송용 스피커의 음향 특성 비교)

  • Jeong, Jeong-Ho;Seo, Bo-Youl;Park, Kye-Won;Shin, Yi-Chul;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, the acoustic characteristics of 13 types of emergency broadcasting speakers were tested under the test set-up of UL 2043 and compared. When the sound pressure level of 1 W speakers was compared with speakers with a 15 W output, the SPL of the 15 W speakers was approximately 20 dB higher in some frequency bands. Loudness analysis showed that people can recognize emergency sound from a 15 W speaker twice as loud as the emergency sound from 1 W speakers. The analysis results on the articulation index (room) had an opposite tendency with loudness results, meaning that small speakers can generate clearer sound. Therefore, it is necessary to improve emergency broadcasting speakers to generate louder and clearer sound. Moreover, a performance evaluation standard is needed based on the reasonable and quantitative measurements and evaluations of the acoustic characteristics of the emergency-broadcasting speakers so that a sufficient and clear sound can be generated in various spaces. In addition, it is necessary to establish standards for the clarity of emergency broadcasting in various spaces.

Analysis of Propagation Environment for Selecting R-Mode Reference and Integrity Station (R-Mode 보정국과 감시국 선정을 위한 전파환경 분석에 관한 연구)

  • Jeon, Joong-Sung;Jeong, Hae-Sang;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.45 no.1
    • /
    • pp.26-32
    • /
    • 2021
  • In ocean field, the spread of the Fourth Industrial Revolution based on information and communication technology requires high precision and stable PNT&D (Position, Navigation, Timing and Data). As the IMO (International Maritime Organization) and IALA (The International Association of Marine Aids to Navigation and Lighthouse Authorities) are requiring backup systems due to mitigate vulnerabilities and the increase of dependency on GNSS (Global Navigation Satellite System), Korea is conducting a research & development of R-Mode. An DGPS (Differentiate Global Positioning System) reference station that uses MF, an existing maritime infrastructure, and AIS (Automatic Identification System) base stations that use 34 integrity station and VHF will be utilized in this study to avoid redundant investment. Because there are radio shadow areas that display low signal levels in the west sea, the establishment of new R-Mode reference and integrity station will be intended to resolve problems regrading the radio shadow area. Because the frequency has a characteristic in that radio wave transmits well along the ground (water surface) in low frequency band, simulation and measurement were conducted therefore this paper to propose candidate sites for R-Mode reference and integrity station resulted through p wave's propagation characteristics analysis. Using this paper, R-Mode reference and integrity station can be established at appropriate locations to resolve radio shadow areas in other regions.

CNN Based Spectrum Sensing Technique for Cognitive Radio Communications (인지 무선 통신을 위한 합성곱 신경망 기반 스펙트럼 센싱 기법)

  • Jung, Tae-Yun;Lee, Eui-Soo;Kim, Do-Kyoung;Oh, Ji-Myung;Noh, Woo-Young;Jeong, Eui-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.276-284
    • /
    • 2020
  • This paper proposes a new convolutional neural network (CNN) based spectrum sensing technique for cognitive radio communications. The proposed technique determines the existence of the primary user (PU) by using energy detection without any prior knowledge of the PU's signal. In the proposed method, the received signal is high-rate sampled to sense the entire spectrum bands of interest. After that, fast Fourier transform (FFT) of the signal converts the time domain signal to frequency domain spectrum and by stacking those consecutive spectrums, a 2 dimensional signal is made. The 2 dimensional signal is cut by the sensing channel bandwidth and inputted to the CNN. The CNN determines the existence of the primary user. Since there are only two states (existence or non-existence), binary classification CNN is used. The performance of the proposed method is examined through computer simulation and indoor experiment. According to the results, the proposed method outperforms the conventional threshold-based method by over 2 dB.

Design and Fabrication of Dual Linear Polarization Antenna for mmWave Application using FR-4 Substrate

  • Choi, Tea-Il;Yoon, Joong-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2022
  • In this paper, we propose 1×2 array antenna with dual linear polarization characteristics for mmWave band operation. The proposed antenna is designed two microstirp feeding structure and FR-4 substrate, which is thickness 0.4 mm, and the dielectric constant is 4.3. The size of 1×2 array antenna is 2.33 mm×2.33 mm, and total size of array antenna is 13.0 mm×6.90 mm. From the fabrication and measurement results, bandwidths of 1.13 GHz (28.52~29.65 GHz) for port 1 and 1.08 GHz (28.45~29.53 GHz) for port 2 were obtained based on the impedance bandwidth. Cross polarization ratios are obtained from 7.68 dBi to 16.90 dBi in case of vertical polarization, and from 7.46 dBi to 15.97 dBi in case of horizontal polarization for input port 1, respectively. Also, cross polarization ratios are obtained from 8.59 dBi to 13.72 dBi in case of vertical polarization and from 9.03 dB to 14.0 dB in case of horizontal polarization for input port 2, respectively.

Evanescent-mode Waveguide Band-pass Filter Applied by Novel Metal Post Capacitor (새로운 금속막대 커패시터를 적용한 감쇄모드 도파관 대역통과 여파기)

  • Kim, Byung-Mun;Yun, Li-Ho;Lee, Sang-Min;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2022
  • In this paper, a novel small-diameter cylindrical post capacitor inserted into an evanescent-mode rectangular waveguide (EMRWG) is proposed for easier tuning. In order to feed the EMRWG, the proposed structure uses a single ridge rectangular waveguide with the same width and height as the waveguide at the input and output ends. The inserted post capacitor are made up a circular groove formed in the center of the lower part of the broad wall of the EMRWG, and a concentric cylindrical post inserted into the upper part. First, the equivalent circuit model for the proposed structure is presented. When the EMRWG and the single ridge waveguide are combined, the joint susceptance and the turns ratio of the ideal transformer are calculated by two simulations using HFSS (3d fullwave simulator, Ansoft Co.) respectively. The susceptance and resonance characteristics of the inserted post were analyzed by using the obtained parameters and the characteristics of the EMRWG. A 2-post filter with a center frequency of 4.5 GHz and a bandwidth of 170 MHz was designed using a WR-90 waveguide, and the simulation results by using the HFSS and CST, equivalent circuit model were in good agreement.

Implementation and Verification for the Low RCS Characteristics of Active Phased Array Antenna (능동위상배열 안테나의 저피탐 특성 구현 및 검증)

  • Joung-Myoung Joo;;Heeduck Chae;Jongkuk Park;Young-Jo Choi;Hyeong-Ki Lee;Jeongyun Han;Jeong-Hwan Jeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2023
  • As the latest weapon systems and electronic equipments are increasingly demanding stealth technology to improve the survivability of allies, it is necessary to implement low-observability technology that reduces the radar cross section(RCS). In order to implement this stealth technology, a method for low RCS characteristics by applying a shape design or a electromagnetic wave absorber is widely used. However, active phased array antennas have structural limitations in shape design, also when a absorber is applied to it, the performance of the antenna is degraded. Therefore, in this paper, in order to realize the low RCS characteristics of the active phased array antenna operating in the X-band, individual radiating elements suitable for applying the radio wave absorber were selected, and a 13x13 array antenna was designed and manufactured. Next, by comparing the measured results of the relative RCS and electrical performance for the manufactured antenna according to the presence and type of the absorber, it is shown that the electrical performance is maintained at an equal or higher level while obtaining the low RCS characteristics. Thereby the method proposed in this paper for implementing the low RCS characteristics was validated. Finally, it was confirmed that when the wave absorber is applied to the array antenna, the limitation of its performance deterioration can be overcome.

A Study on the Dental Hygienists' Reactions to Noise When Occurred in Dental Clinic (치과병원에서 발생하는 소음에 대한 치과위생사의 반응)

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.453-459
    • /
    • 2009
  • The purposes of this research were to evaluate the relationships of between characteristics of noise and annoyance of dental hygienist by noise in dental clinic. To investigate the dental clinic workers' reactions to noise when occurred in dental clinic, the noise level test in dental clinic and questionnaire were taken. As a result of noise evaluation, It shows that the range of noise level was 67.7~78.3dB(A) and frequency was very high (more than 4KHz). It's seem to be begins occurrence of stamina-loss, contraction of peripheral blood vessel, decrease of adrenocortical hormones. Most of respondents were affected by noise: 67% of respondents were nervous about noise and the rest of respondents were bearable. Analysis by NR-curve showed that it was exceed the noise permit level in working space. As a result of correlation - test, the more exposed dental hygienist to noise, the more felt the unpleasantness and fatigue. It's hard to sufficient explanation to patients about the dental treatment. So it's thoughts that insufficient explanation will negative impact on the patients' satisfaction and increase competitiveness in dental clinics. To remedy a unpleasantness and fatigue of noise in dental hygienist, it's considered that making an offer the ear protection and choosing the low noise-vib. equipment and using the masking effect. Therefore, It can be provide a pleasant working environment with dental hygienist and It will have a great advantage to dental clinics to improve their competitiveness.

  • PDF

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF

The Association of Life Event Stress, Family Function and Cancer (암과 생활사건스트레스 및 가족기능의 연관성)

  • Choi, Youn-Seon;Lee, Young-Mee;Hong, Myung-Ho;Chun, Byung-Chul
    • Journal of Hospice and Palliative Care
    • /
    • v.2 no.2
    • /
    • pp.114-124
    • /
    • 1999
  • Purpose : To clarify the relation between psychosocial variables and cancer in Korea. Methods : Case-control study. Participants: 239 subjects in 2 university hospitals in Seoul completed a series of psychometric instruments(the Olson's FACES III and the Lee's 98-items life event scale). Results : In bivariable analysis, there were statistically significant difference in age and economic status(income): marginal significance in education status and marital status between the cases and controls. The family function type and stress score were not significantly different. The result of multivariable logistic regression, analysis showed that the risk of cancer was associated with economic status and marital status, but neither the family function nor the life event stress. Conclusion : In this study, we cannot prove the statistical association between the family function, life event stress and cancer. It is necessary to persevere in our efforts to clarify the relation between stress and disease and to develop the useful tools to measure the Korean family function and life event stress.

  • PDF

On the Suitability of the Korean Standard Time (한국 표준시 제도의 타당성에 대한 연구)

  • Hong, Sung-Gil;Ryu, Chan-Su;Kim, Young-Sung
    • Journal of the Korean earth science society
    • /
    • v.23 no.6
    • /
    • pp.494-506
    • /
    • 2002
  • The Korean Standard-Time (KST) in practice is about 30 minutes earlier than Korea’s solar-time. Suitability of tile KST is analysed by whether it is suitable for the society in general and for the mental and physical health of the Korean people. About 56% of the countries in the world use single standard-time coincident, 18% are 30 minutes earlier, and 21% are an hour or more earlier than their solar-times, respectively, and only 5% have standard-times 30 minutes later than their solar-time. This means adoption of the standard-time earlier than the solar-time is rather acceptable in most countries without any harm to the mental and physical health of their people. Because Korea is located on the western margin of the I-time zone (which is used standard longitude of 135$^{\circ}$E and is used as KST), KST is about 30 minutes earlier than Korea’s solar-time. This situation does not seem to affect adversely the physical, physiological or psychological activities of the people of Korea. It also helps in effective use of the daily time schedule throughout the year, moreover it diminishes the necessity of the summer-time system in the Korea. If H$^{\ast}$-time of the longitude of 127.5$^{\circ}$E that passes through middle of the Korean peninsular is used as KST, non-integer time difference from UTC is inevitable which may be of great inconvenience, and also the introduction of a summer-time system like most countries in high latitude, using their standard-time coincidentally with or even earlier than their solar time, will become essential.