• Title/Summary/Keyword: S parameters defect

Search Result 88, Processing Time 0.023 seconds

Copper Filling to TSV (Through-Si-Via) and Simplification of Bumping Process (비아 홀(TSV)의 Cu 충전 및 범핑 공정 단순화)

  • Hong, Sung-Jun;Hong, Sung-Chul;Kim, Won-Joong;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.79-84
    • /
    • 2010
  • Formation of TSV (Through-Si-Via) with an Au seed layer and Cu filling to the via, simplification of bumping process for three dimensional stacking of Si dice were investigated. In order to produce the via holes, the Si wafer was etched by a DRIE (Deep Reactive Ion Etching) process using $SF_6$ and $C_4F_8$ plasmas alternately. The vias were 40 ${\mu}m$ in diameter, 80 ${\mu}m$ in depth, and were produced by etching for 1.92 ks. On the via side wall, a dielectric layer of $SiO_2$ was formed by thermal oxidation, and an adhesion layer of Ti, and a seed layer of Au were applied by sputtering. Electroplating with pulsed DC was applied to fill the via holes with Cu. The plating condition was at a forward pulse current density of 1000 mA/$dm^2$ for 5 s and a reverse pulse current density of 190 mA/$dm^2$ for 25 s. By using these parameters, sound Cu filling was obtained in the vias with a total plating time of 57.6 ks. Sn bumping was performed on the Cu plugs without lithography process. The bumps were produced on the Si die successfully by the simplified process without serious defect.

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

The Study of Aerial Triangulation Using GPS (GPS를 이용한 사진기준점 측랑에 관한 연구)

  • 이재원;문두열;김정희;김진수
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.181-191
    • /
    • 2004
  • Nowadays, GPS-photogrammetry can be applied to the basemap production, a land register and NGIS. And from now on, as the increase of GPS receiver rate, the study on the interpolation methods considering the exact movement of an aircraft at photoflight and the study on the supplement of GPS defect by INS are required continuously. GPS-Photogrammetry, which are based on the direct measurement of the projection centers and attitude at the moment of camera exposure time through loading the GPS receiver in aircraft. This photogrammetric methods can of for us to acquire the exterior orientation parameters with only minimum ground control points, even the ground control process could be completely skipped. Consequently, we can drastically reduce the time and cost far the mapping process. In this thesis, two test flights were conducted in area to evaluate the performance of accuracy and efficiency through the analysis of results between the two photogrammetric methods, that is, traditional photograrammetry, GPS-Photogrammetry. Test results shows that a large variety of advantages of GPS-Photogrammetry against traditional photogrammetry is to be verified. Especially, the number of ground control points for the exterior orientation could be saved more than 70~80%, and the cost far map production 30~50%, respectively. In addition, it was convinced that the large reduction of control points has not any effect on the block accuracy.

  • PDF

The Safety of Microsurgical Head and Neck Reconstruction in the Elderly Patients (고령 환자군에 있어서 유리피판술을 이용한 두경부재건의 안전성)

  • Choi, Bong Kyoon;Kim, Young Seok;Lee, Won Jai;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.289-293
    • /
    • 2006
  • By means of microsurgical free-tissue transfer providing a large amount of required tissue, the surgeon can resect tumoral tissue more safely, which allows tumor-free margins and enhances the reliability of the ablative surgery that otherwise could not be performed radically. The morbidity of elective free-tissue transfer seems to be quite low, carrying acceptable risks for most patients. But the elderly patients are at risk for cardiac and respiratory problems, deep vein thrombosis, pulmonary emboli and infection merely as a function of age. This study was undertaken to define further risks of the elderly population with regards to free-tissue transfer. We retrospectively reviewed our experience with 110 microsurgical free-tissue transfers for head and neck reconstruction in patients greater than 60 years of age. Microsurgical procedures in all cases were preformed by the plastic and reconstructive department at Yonsei medical center. The investigated parameters were patient demographics, past medical history, American Society of Anesthesiologists(ASA) status, site and cause of defect, the free tissue transferred and postoperative complication including free-flap success or failure. There were 46 patients in the age group from 60 to 64 years, 34 patients from 65 to 70 years, and 30 patients 70 years or older. There happened 3 flap losses, resulting in a flap viability rate of 97%. Patients with a higher ASA designation experienced more medical complication(p=0.05, 0.01, 0.03 in each age group I, II, III) but not surgical complication p=0.17, 0.11, 0.54 in each age group I, II, III). And the relationship between postoperative complication and age groups was not significant. These observations suggest that major determinant for postoperative medical complication be the patient's American Society of Anesthesiologists score, and chronologic age alone should not be an exclusion criterion when selecting patients for free-tissue transfer

Comparison of Mechanical properties and Surface Friction of White Metals Produced by Centrifugal and Laser Cladded on SCM440 (원심주조방식과 레이저 클래딩 증착법을 통한 화이트메탈의 기계 및 마찰특성 비교)

  • Jeong, Jae-Il;Kim, Dong-Hyuk;Park, Jin-Young;Oh, Joo-Young;Choi, Si-Geun;Kim, Seock-Sam;Cho, Young Tae;Lee, Ho;Ham, Seung-Sik;Kim, Jong-Hyoung
    • Tribology and Lubricants
    • /
    • v.34 no.3
    • /
    • pp.84-92
    • /
    • 2018
  • Bearings are essential for reducing vibration and wear, in order to achieve high durability and increase longevity. White metal treatment of tilting pads via centrifugal casting method has the possibility of increasing durability. However, this manufacturing method has drawbacks such as long processing time, high defect rate, and harmful health effects. Laser cladding deposition technique is a powerful method that can address these issues by decreasing the processing time and providing good adhesion. In this study, we suggest optimum conditions for laser cladding deposition that can be used in industrial applications. We deposited a soft white metal layer on SCM440 that is primarily used in shafts to minimize wear of bearing pads. During the laser deposition process, we controlled factors such as laser power, powder feed rate, and laser head speed to determine the optimum conditions. In addition, we measured the hardness using micro Vickers, and performed field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and friction tests to investigate the mechanical properties and surface characteristics for different parameters. Based on the experimental results, we suggest that laser power, powder feed rate, and laser head speed of 1.3 kW, 2.5 rpm, and 10 mm/s, respectively, constitute the optimum conditions for producing white metals using laser cladding.

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

Evaluation of Database Comparison Methods for 18F-FDG Brain PET/CT (18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2015
  • Purpose Various database comparison methods(DCM) are used for analyzing functional neuro-imaging. It is possible to statistically evaluate decreased or increased metabolism of abnormal patient's brain by comparing with asymptomatic controls in DCM. And results of DCM are additionally used for easily explaining defect region. The aim of this study was to evaluate usefulness of statistical parametric mapping(SPM) and scenium. Materials and Methods Data of 15 patients($62.02{\pm}15.03year$) underwent $^{18}F-FDG$ brain PET/CT were collected and analyzed. Biograph TruePoint 40 with TrueV, (Siemens) was used as a PET/CT scanner. Scenium(version 4.0) in Syngo.via(version VA30A) and SPM99 were applied for statistical evaluation. Consistency between PET reading and result of DCM were evaluated by 5 nuclear medicine physicians through a questionnaire survey. SUV and SD changes were evaluated by changing iteration, gaussian filter and matrix size in scenium. And average required time for generating result of SPM99 and scenium was compared by 3 medical technologists. Results Consistency from the result of SPM99 and scenium showed 84% and 92.4% compare to PET reading. When iteration 4, FWHM 8 and matrix size 168, SUV and SD were decreased by 0.59%, 8.73%, 4.69%, 20.38% and 0.88%, 8.25% respectively compare to routine parameter(iteration 8, FWHM 2 and matrix size 336) of scenium. Average required time of SPM99 and Scenium took 282 seconds and 116 seconds to generate result. Conclusion Results of SPM99 and Scenium showed high consistency compare to PET reading. Various parameters can be controled by user when using SPM. However, normal database needs to be acquired. And it takes significant amount of time and effort for the first set up. On the other hand, Scenium provides normal database even though modifiable parameters are limited. Therefore, more informations could be provided for brain PET/CT if properly understanding and selecting each DCM.

  • PDF

The Result of Radiotherapy for Pituitary Adenoma (뇌하수체 선종의 방사선치료 결과)

  • Lee, Hyun-Joo;Yang, Kwang-Mo;Cho, Heung-Lae;Shon, Seung-Chang;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.297-303
    • /
    • 1997
  • Purpose : To evaluate the prognostic factors for disease-free survival and long-term results of radiotherapy for pituitary adenoma. Methods and Materials : The study involved a retrospective review of out-come in a series of 27 patients with pituitary adenoma, between 1984 and 1995 at Paik hospital. The study included 20 patients treated with surgery and postoperative radiotherapy and 7 with radiotherapy alone. The patients were followed for 12-146 months (median : 97 months). Seventeen were men and 10 were women. The numbers of functioning and nonfunctioning pituitary adenorna were 22 and 5 respectively and those of microadenoma and macroadenoma were 4 and 23 respectively. The radiation doses of 5040-5580cGy (median : 5040cGy) were deliverd over 5-7 weeks, using 4MV LINAC. The prognostic factors were analyzed by log-rank test. Results: For radiation therapy alone, the 5YSR was 100% and progression free survival rate was 85.8%, The tumor was controlled in 6/7 (85.8%). For surgery and postoperative radiotherapy. the 5YSR, progression free survival rate and local control rate were 95%, 84.8%, and 89.5% respectively. The parameters of tumor size, hormone secretion, radiation dose. radiotherapy field size were evaluated in a uni- and multivariate analysis and all the factors were not statisticaIty significant (P>0.05). Eleven of 12 (92%) with visual field defect experienced normalization or improvement, and 5 for 7 evaluabie patients with hyperprolactinoma achived normalization in 4 and decrement in S patients. Only 2 patients developed mild degree of Panhypopituitarism. Conclusion: The radiotherapy appears to be effective in controiling clinical symptoms and signs resulting from pituitary adenoma. Local control rate with radiotherapy alone or with surgery and postoperative radiotherauy was comparable. There was a trend toward high recurrence rate in Patients with nonfunctioning or prolactin secretion tumor and larger radiation field sizes.

  • PDF