• Title/Summary/Keyword: S/N 비

Search Result 3,307, Processing Time 0.036 seconds

Comparison of Methods using Radial and Femoral Arteries in Coronary Angiography (심장동맥 조영술 시 노동맥과 넙다리동맥을 이용한 방법 비교)

  • Ahn, Jun-Ho;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.87-94
    • /
    • 2022
  • In this study, 61 patients who underwent coronary angiography from March 2018 to August 2019 were divided into Group I (Radial, n=34 patients) and Group II (Femoral, n=27 patients), and compared and analyzed methods using radial and femoral arteries when coronary angiography was performed. As a result of comparative analysis, Catheter usage was reduced in the examination using radial artery, and in the abnormal shape of blood vessels, Loops arterial abnormalities were more in the radial artery (20.6% vs, 0%, p<0.05), and it was found that the abnormal shape of the radial vessels increased with age. 60s, 70s, 80s, 90s or older (0%, 18.2%, 25.0%, 100%)

Seasonal Mineral Nutrient Absorption Characteristics and Development of Optimum Nutrient Solution for Rose Substrate Culture in a Closed Hydroponic System (순환식 수경재배에서 재배시기별 장미의 무기이온 흡수특성과 적정 배양액 조성)

  • Yang, Eun-Young;Park, Keum-Soon;Oh, Jeong-Sim;Lee, Hye-Jin;Lee, Yong-Beom;Lee, Ju-Hyun
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.354-362
    • /
    • 2009
  • This study was performed to develop a suitable nutrient solution for standard rose substrate culture in a closed hydroponic system. 1/4, 1/2, 2/3 and 1 strength of the nutrient solution made by Japan National Institute of Vegetable and Tea Science (JNIVT) were supplied. The photosynthesis rate, quality and growth of cut flower were higher in the 1/2 and 2/3 strength of nutrient solution during high and low temperature period. Based on the above results, optimum nutrient solutions (UOS) were composed by nutrientwater (n/w) absorption ratio with 1/2S ($NO_{3^-}N$ 6.8, $NH_{4^-}N$ 0.7, $PO_{4^-}P$ 2.0, K 3.8, Ca 3.0, Mg 1.2, $SO_{4^-}S$ $1.2me{\cdot}L^{-1}$) at high temperature season and 2/3($NO_{3^-}N$ 9.7, $NH_{4^-}N$ 0.8, $PO_{4^-}P$ 2.2, K 5.0, Ca 3.9, Mg 1.5, $SO_{4^-}S$ $1.5me{\cdot}L^{-1}$) at low temperature season. The results of suitability examination showed that the EC level in newly composed nutrient solution (UOS) was more stable than other nutrient solutions due to its large amount of calcium and potassium. The growth of cut flower cultivated with UOS was higher than those of other nutrient solutions. Especially, the yield of cut flowers in UOS nutrient solution increased 1.4 times than that of other nutrient solution treatments. Consequently, the new nutrient solution investigated in this experiment was suitable for rose cultivation in a closed hydroponic system.

질소유량 변화와 고온 열처리에 의한 HfN 박막의 Nano-electrotribology 특성 연구

  • Park, Myeong-Jun;Kim, Seong-Jun;Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.354.1-354.1
    • /
    • 2014
  • Hafnium nitride (HfN) 박막은 고온에서의 안정성과 낮은 비저항 그리고 산소확산에 대한 억제력을 가지고 있기 때문에 확산방지막으로 많은 연구가 진행 되고 있다. 현재까지 진행된 대부분의 연구는 HfN 박막의 전기적인 특성과 구조적인 특성에 대한 것이었고 다양한 연구 결과가 보고되었다. 하지만 기존의 연구들은 박막의 nano-electrotribology 특성에 대한 연구가 부족하여 박막 적층 공정시 요구되는 물성에 대한 연구가 절실하다. 따라서 본 연구에서는 HfN 박막의 증착조건 및 열처리조건에 따른 nano-electrotribology 특성 변화를 확인하고자 하였다. HfN박막은 rf magnetron sputter를 이용하여 Si 기판위에 Hf target으로 질소 유량을 변화시키며 증착하였고 가열로에서 $600^{\circ}C$$800^{\circ}C$로 20분간 열처리를 실시하였다. 열처리한 박막과 as-deposited 상태의 박막을 nano-indenter를 통하여 나노기계 전기적인 특성을 분석하였다. nano-indenter는 박막에 인가된 stress와 탄성계수(elastic modulus), 표면경도(surface hardness)와 같은 특성을 직접적인 tip 접촉을 통하여 in-situ로 분석할 수 있는 장비이다. 실험결과 HfN박막을 $600^{\circ}C$로 열처리 한 경우 표면경도가 16.20에서 18.59 GPa로 증가하였다. 표면경도의 증가는 열처리 시 박막내에 compressive stress가 생성되었기 때문이라고 생각된다. 그러나 $800^{\circ}C$로 열처리 한 경우 표면경도가 16.93 GPa로 감소하였는데 이는 표면균열 발생으로 인한 stress relaxation 때문인 것으로 생각된다. 증착 시 주입되는 질소의 유량과 열처리 온도는 HfN박막의 기계적 안정성에 영향을 미치는 중요한 요소임을 본 실험을 통해 확인하였다.

  • PDF

Effect of Organic Solvents on Lipase for Interesterification of Fats and Oils (유지의 에스테르교환에 있어서 유기용매가 리파제에 미치는 영향)

  • Kwon, Dae-Y.;Rhee, Joon-S.
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.490-494
    • /
    • 1985
  • The effect of organic solvents on the stability and catalytic activity of the microbial lipase from Rhizopus arrhizus for interesterification of fats and oils has been examined. The reaction system used was nonaqueous solvent system (two phase system). The solvents examined were 5 hydrocarbons (n-hexane, n-heptane, n-octane, isooctane, and cyclohexane) and 3 ethers (diethylether, diisopropylether, di-n-butylether). The results revealed that diisopropylether and isooctane are superior to the other solvents examined for interesterification of fats and oils in two phase systems.

  • PDF

Method for Measuring Prompt Fission Neutron Energy Spectrum by Means of Threshold Activation Detectors (발단 방사화 검출기를 이용한 핵분열 즉발 중성자 에너지 스펙트럼 측정방법)

  • 노성기;신희성;박종묵
    • Nuclear Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.410-415
    • /
    • 1990
  • Prompt fission neutron energy spectrum as a function of energies of neutron inducing fission has been calculated en the basis of the Madland-Nix(MN) model. The resultant spectra have been weighted to excitation functions of $^{27}$ Al(n, $\alpha$), $^{32}$ S(n, p) and $^{115}$ In(n, n') threshold reactions in order to get the average cross sections and then spectral indices which are defined as the average cross section ratio for two selective threshold reactions among the above three. It is appeared that spectral indices together with the neutron spectra are varying with energies of neutron inducing fission. This may indicate that the prompt fission neutron energy spectrum can be determined by measuring experimentally the spectral index.

  • PDF

An Optimization of 600V GaN Power SIT (600V급 GaN Power SIT 설계 최적화에 관한 연구)

  • Oh, Ju-Hyun;Yang, Sung-Min;Jung, Eun-Sik;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.5-5
    • /
    • 2010
  • Gallium Nitride(GaN)는 LED, Laser 등에 사용되는 광학적 특성뿐만 아니라 Wide Bandgap의 전기적 특성 또한 주목받고 있다. 본 논문은 600V급 GaN(Gallium Nitride) Power SIT(Static Induction Transistor)에 대해서 Design Parameter 변환에 따른 전기적 (Breakdown Voltgage, On-state Voltage Drop)특성과 열적 (Lattice Temperature Distribution)특성변화를 분석하여 소자가 갖는 구조적 손실을 최소화하였다. 또한, 기존 실리콘 기반 전력소자와 특성 비교를 통하여 GaN Power SIT의 우수성을 증명하였다. GaN Power SIT 소자 설계 및 최적화를 위해서 Silvaco사의 소자 시뮬레이터인 ATLAS를 사용하였다. 실험 결과 수 ${\mu}m$의 소자 두께만으로도 실리콘 전력소자에 비해 더 뛰어난 열 특성과 더 적은 전력소모를 갖는 600V급 GaN Power SIT 소자를 구현할 수 있었다.

  • PDF

Development of Integer DCT for VLSI Implementation (VLSI 구현을 위한 정수화 DCT 개발)

  • 곽훈성;이종하
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.12
    • /
    • pp.1928-1934
    • /
    • 1993
  • This paper presents a fast algorithm of integer discrete cosine transform(IDCT) allowing VLSI implementation by integer arithmetic. The proposed fast algorithm has been developed using Chen`s matrix decomposition in DCT, and requires less number of arithmetic operations compared to the IDCT. In the presented algorithm, the number of addition number is the same as the one of Chen`s algorithm if DCT, and the number of multiplication if the same as that in DCT at N=8 but drastically decreasing when N is above 8. In addition, the drawbacks of DCT such as performance degradation at the finite length arithmetic could be overcome by the IDCT.

  • PDF

Press Formabilities of Aluminum Sheets for Autobody Application (차체용 알루미늄 판재의 프레스 성형성)

  • Kim, Y.S.;Kim, K.S.;Kwon, N.C.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.73-83
    • /
    • 1994
  • Press formabilities of aluminum sheets for automobile body were investigated. Plane strain stretching test (called RIST-PSST), cupping test and U bending test were performed to assess the press formability of aluminum sheets respectively. The results showed that aluminum sheets are generally inferior to cold-rolled steel sheet of deep drawing quality (CSP3N) in press formability. The limiting punch height (LPH) and limiting plane strain (FLCo) of aluminum sheets are 50%-70% level compared to that of CSP3N. Moreover, the limiting drawing ratios(LDR) of aluminum sheets are ranged between 1.95 and 2.1. The poor press formability of aluminum sheets is responsible for low values of total elongation and plastic anisotropy parameter in tensile characteristic. The shape fixability of aluminum sheets evaluated in U bending test is very poor due to its low elastic modulus compared to CSP3N.

  • PDF

A Study on New High Density DRAM Cell (고밀도 DRAM Cell의 새로운 구조에 관한 연구)

  • Yi, Cheon-Hee
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.124-130
    • /
    • 1989
  • For the higher density DRAM'S, innovations in fabrication process and circuit design which have led to dramatic density improvement are discussed from the desinger's perspective. A new dynamic RAM cell called Trench Epitaxial Transistor Cell(TETC) using trench technics and SEG have been developed for use in future megabit DRAMS. Storge electrode with $n^+$-polysilicon and $n^+$-source electrode are self-contacted in TETC. With keeping the storage capacitance large enough to prevent soft errors, the cell size reduced to 30% compare with existing BSE cell by utilizing the vertical capacitor made along the isolation region.

  • PDF

Analysis of Cutting Parameters for $Si_3 N_4$-hBN Machinable Ceramics Using Tungsten Carbide Tool (초경공구를 사용한 $Si_3 N_4$-hBN 머시너블 세라믹 가공에서 절삭 파라미터 분석과 결정)

  • 장성민;조명우;조원승;박동삼
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.36-43
    • /
    • 2003
  • In machining of ceramic materials, they are very difficult-to cut materials because of there high strength and hardness. Machining of ceramics are characterized by cracking and brittle fracture. Generally, ceramics are machined using conventional method such as finding and polishing. However these processes are generally costly and have low MRR(material removal rate). This paper focuses on determining the optimal levels of process parameters for products with CNC machining center. For this purpose, the optimization of cutting parameters is performed based on experimental design method. A design and analysis of experiments is conducted to study the effects of these parameters on the surface roughness by using the S/N ratio, analysis of ANOVA and F-test. Cutting parameters, namely, cutting speed, feed and depth of cut are optimized with consideration of the surface roughness.