• Title/Summary/Keyword: S/B ratio

Search Result 2,669, Processing Time 0.034 seconds

Evaluation of Elastic Properties of DLC Films Using Substrate Etching Techniques (기판 Etching 기법을 이용한 DLC 필름의 탄성특성 평가)

  • 조성진;이광렬;은광용;한준희;고대홍
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.8
    • /
    • pp.813-818
    • /
    • 1998
  • A simple method to measure the elastic modulus E and Poisson's ratio v of diamod-like carbon (DLC) films deposited on Si wafer was suggested. Using the anisotropic etching technique of Si we could make the edge of DLC overhang free from constraint of Si substrate. DLC film is chemically so inert that we could not on-serve any surface damage after the etching process. The edge of DLC overhang free from constraint of Si substrate exhibited periodic sinusoidal shape. By measuring the amplitude and the wavelength of the sinu-soidal edge we could determine the stain of the film required to adhere to the substrate. Since the residual stress of film can be determine independently by measurement of the curvature of film-substrate com-posite we could calculated the biaxial elastic modulus E/(1-v) using stress-strain relation of thin films. By comparing the biaxial elastic modulus with the plane-strain modulus E/(1-{{{{ { v}^{2 } }}) measured by nano-in-dentation we could further determine the elastic modulus and Poisson's ratio independently. This method was employed to measure the mechanical properties of DLC films deposited by {{{{ { {C }_{6 }H }_{6 } }} rf glow discharge. The was elastic modulus E increased from 94 to 169 GPa as the {{{{ { V}_{ b} / SQRT { P} }} increased from 127 to 221 V/{{{{ {mTorr }^{1/2 } }} Poisson's ratio was estimated to be abou 0.16∼0.22 in this {{{{ { V}_{ b} / SQRT { P} }} range. For the {{{{ { V}_{ b} / SQRT { P} }} less than 127V/{{{{ {mTorr }^{1/2 } }} where the plastic deformation can occur by the substrate etching process however the present method could not be applied.

  • PDF

SO2 Injury to Shoots in Five Apple Cultivars (몇가지 사과품종(品種)의 신초(新梢)에 미치는 SO2 가스의 피해(被害))

  • Ku, Ja-Hyeong
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.119-124
    • /
    • 1979
  • In order to examine $SO_2$ injury to apple shoots, cutting shoots of five cultivars were exposed to 3 ppm $SO_2$ in vase life conditions. 1. The most sensitive cultivar to $SO_2$ was 'Rall's Genet', and 'Starking' was most tolerant among cultivars tested. 2. Ethylene production of shoots showed peak after 8 hours exposure, when visible injury was not appeared, and was decreased with increase in exposure time. 'Rall's Genet' showed slower decrease in ethylene production than other cultivars. 3. Chlorophyll a, b and a/b ratio were decreased in all cultivars after 40-hr exposures to 3 ppm $SO_2$ and greatly decreased in 'Rall's Genet' compared to other cultivars.

  • PDF

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses (SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.

Optimization of Maillard Reaction in Model System of Glucosamine and Cysteine Using Response Surface Methodology

  • Arachchi, Shanika Jeewantha Thewarapperuma;Kim, Ye-Joo;Kim, Dae-Wook;Oh, Sang-Chul;Lee, Yang-Bong
    • Preventive Nutrition and Food Science
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2017
  • Sulfur-containing amino acids play important roles in good flavor generation in Maillard reaction of non-enzymatic browning, so aqueous model systems of glucosamine and cysteine were studied to investigate the effects of reaction temperature, initial pH, reaction time, and concentration ratio of glucosamine and cysteine. Response surface methodology was applied to optimize the independent reaction parameters of cysteine and glucosamine in Maillard reaction. Box-Behnken factorial design was used with 30 runs of 16 factorial levels, 8 axial levels and 6 central levels. The degree of Maillard reaction was determined by reading absorption at 425 nm in a spectrophotometer and Hunter's L, a, and b values. ${\Delta}E$ was consequently set as the fifth response factor. In the statistical analyses, determination coefficients ($R^2$) for their absorbance, Hunter's L, a, b values, and ${\Delta}E$ were 0.94, 0.79, 0.73, 0.96, and 0.79, respectively, showing that the absorbance and Hunter's b value were good dependent variables for this model system. The optimum processing parameters were determined to yield glucosamine-cysteine Maillard reaction product with higher absorbance and higher colour change. The optimum estimated absorbance was achieved at the condition of initial pH 8.0, $111^{\circ}C$ reaction temperature, 2.47 h reaction time, and 1.30 concentration ratio. The optimum condition for colour change measured by Hunter's b value was 2.41 h reaction time, $114^{\circ}C$ reaction temperature, initial pH 8.3, and 1.26 concentration ratio. These results can provide the basic information for Maillard reaction of aqueous model system between glucosamine and cysteine.

Transmission of 10 Gb/s optical signais over 320 km of a dispersion shifted fiber (10Gb/s 광신호의 320km 분산천이 광섬유 전송실험)

  • 이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.64-67
    • /
    • 1999
  • We have been implemented 10 Gb/s-320 km of dispersion-shifted fiber (DSF) transmission. The optical link consists of a 10 Gb/s optical transceiver, an optical booster amplifier, 3 sets of optical in-line amplifiers, an optical preamplifier and transmission fibers. Firstly, we investigated the Q-factor characteristics in terms of optical signal to noise ratio (OSNR) of 320 km of DSF, measured receiver sensitivity is -27 dBm and power penalty is 2 dB, respectively. We concluded that optical SNR degradation and path penalty gives rise to 1 dB penalty, respectively.

  • PDF

Voice Quality of Dysarthric Speakers in Connected Speech (연결발화에서 마비말화자의 음질 특성)

  • Seo, Inhyo;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.5 no.4
    • /
    • pp.33-41
    • /
    • 2013
  • This study investigated the perceptual and cepstral/spectral characteristics of phonation and their relationships in dysarthria in connected speech. Twenty-two participants were divided into two groups; the eleven dysarthric speakers were paired with matching age and gender healthy control participants. A perceptual evaluation was performed by three speech pathologists using the GRBAS scale to measure the cepstrual/spectral characteristics of phonation between the two groups' connected speech. Correlations showed dysarthric speakers scored significantly worse (with a higher rating) with severities in G (overall dysphonia grade), B (breathiness), and S (strain), while the smoothed prominence of the cepstral peak (CPPs) was significantly lower. The CPPs were significantly correlated with the perceptual ratings, including G, B, and S. The utility of CPPs is supported by its high relationship with perceptually rated dysphonia severity in dysarthric speakers. The receiver operating characteristic (ROC) analysis showed that the threshold of 5.08 dB for the CPPs achieved a good classification for dysarthria, with 63.6% sensitivity and the perfect specificity (100%). Those results indicate the CPPs reliably distinguished between healthy controls and dysarthric speakers. However, the CPP frequency (CPP F0) and low-high spectral ratio (L/H ratio) were not significantly different between the two groups.

The Effect of Residual Stress on Stress Intensity Factor and Fatigue Crack Growth Rate (잔류응력이 응력세기계수와 피로균열성장율에 미치는 영향)

  • Kang-Yong,Lee;Hong-Key,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.1
    • /
    • pp.43-47
    • /
    • 1984
  • The purpose of this paper is to investigate theoretically the effect of residual stress due to welding in stress intensity factor of a plate containing the Model I Crack in different crack size and location, and on fatigue crack growth rate. The initiation of crack is found to be possible only in the region of tensile residual stress. The most dangerous crack has the values of d/b and a/b equal to about 0.6 and 1.0, respectively, where d/b is the ratio of distance from the crack to welding bead and the width of tensile residual stress region and a/b is the ratio of crack length and tensile residual stress region. The crack perpendicular to and on the line of welding bead and with a/b equal to about 0.6 has maximum stress intensity factor. The theoretical fatigue crack growth rate under residual stress and applied stress, which is obtained from Forman's Law by stress superposition, is relatively in good agreement with Glinka's[8] experimental value. The fatigue crack growth is shown to be retarded due to residual stress distribution.

  • PDF

A 2.5 V 10b 120 MSample/s CMOS Pipelined ADC with High SFDR (높은 SFDR을 갖는 2.5 V 10b 120 MSample/s CMOS 파이프라인 A/D 변환기)

  • Park, Jong-Bum;Yoo, Sang-Min;Yang, Hee-Suk;Jee, Yong;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.4
    • /
    • pp.16-24
    • /
    • 2002
  • This work describes a 10b 120 MSample/s CMOS pipelined A/D converter(ADC) based on a merged-capacitor switching(MCS) technique for high signal processing speed and high resolution. The proposed ADC adopts a typical multi-step pipelined architecture to optimize sampling rate, resolution, and chip area, and employs a MCS technique which improves sampling rate and resolution reducing the number of unit capacitor used in the multiplying digital-to-analog converter (MDAC). The proposed ADC is designed and implemented in a 0.25 um double-poly five-metal n-well CMOS technology. The measured differential and integral nonlinearities are within ${\pm}$0.40 LSB and ${\pm}$0.48 LSB, respectively. The prototype silicon exhibits the signal-to-noise-and-distortion ratio(SNDR) of 58 dB and 53 dB at 100 MSample/s and 120 MSample/s, respectively. The ADC maintains SNDR over 54 dB and the spurious-free dynamic range(SFDR) over 68 dB for input frequencies up to the Nyquist frequency at 100 MSample/s. The active chip area is 3.6 $mm^2$(= 1.8 mm ${\times}$ 2.0 mm) and the chip consumes 208 mW at 120 MSample/s.

Electrical breakdown properties in neon gas mixed with xenon

  • Han S. Uhm;Park, Eun H.;Guansup Cho;Ki W. Whang
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.4
    • /
    • pp.112-121
    • /
    • 2000
  • The paper investigates electrical discharge properties in neon gas mixed with xenon. The breakdown temperature T$\sub$b/ and voltage V$\sub$b/ are obtained in terms of the gas mixture ratio X. It is shown that the breakdown voltage decreases, reaches the minimum value at X=0.02 and then increases again, as the mixture ratio X increases from zero to unity. Therefore, mixing the neon gas with a few percent of xenon is the most beneficial to reduce the breakdown voltage. Plasma density at breakdown in neon gas mixed with xenon is described in terms of the gas mixture ratio. The optimum value of mixture ratio for highest plasma density is found to be Xm=0.03. A preliminary experiment of AC-PDP is carried out for neon gas mixed with a few percent of xenon to verify some of the theoretical models. The experimental data agree qualitatively well with theoretical predictions.

  • PDF