• Title/Summary/Keyword: Rz

Search Result 141, Processing Time 0.025 seconds

Calculation of Pump Light Power in Wideband Optical Phase Conjugator with Highly-Nonlinear Dispersion Shifted fiber (HNL-DSF를 이용한 광대역 광 위상 공액기의 펌프 광 전력 계산)

  • 이성렬;이하철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.473-483
    • /
    • 2004
  • In this paper, we numerically investigated the optimum pump light power best compensating for pulse distortion due to both chromatic dispersion and self phase modulation (SPM) as a function of channel input power in 8 channel ${\times}$ 40 Gbps wavelength division multiplexing (WDM systems. Also we investigated the allowable maximum channel input power dependence on modulation format and fiber dispersion coefficient in the various pump light power of OPC. The considered WDM transmission system is based on path-averaged intensity approximation (PAIA) mid-span spectral inversion (MSSI) compensation method, which has highly-nonlinear dispersion shifted fiber (HNL-SDF) as nonlinear medium of optical phase conjugator (OPC) in the mid-way of total transmission line. We confirmed that optimal pump light power of HNL-DSF OPC depend on modulation format, initial channel input power, total transmission length and fiber dispersion. But optimal pump light power of HNL-DSF OPC must be selected to make power conversion ratio to almost unity. And we confirmed that, if we allow a 1 dB eye opening penalty (EOP), the tolerable maximum channel input power is increased by using RZ than NRZ as modulation format when pump light power of HNL-DSF OPC is not optimal value but another values.

Power-efficiency Analysis of the MIMO-VLC System considering Dimming Control (조광제어를 고려한 MIMO-VLC 시스템의 전력 효율 분석)

  • Kim, Yong-Won;Lee, Byung-Jin;Lee, Byung-Hoon;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.169-180
    • /
    • 2018
  • White light-emitting diodes (LEDs) are more economical than fluorescent lights, and provide high brightness, a high lifetime expectancy, and greater durability. As LEDs are closely connected with people's daily lives, dimming control of LED is an important component in providing energy savings and improving quality of life. In visible light communications systems using these LEDs, multiple input multiple output (MIMO) technology has attracted a lot of attention, in that it can attain the channel capacity in proportion to the number of antennas. This paper analyzes the power performance of three kinds of modulation in visible light communications (VLC) systems applied space-time block code (STBC) techniques. The modulation schemes are return-to-zero on-off keying (RZ-OOK), variable pulse position modulation (VPPM), and overlapping pulse position modulation (OPPM), and dimming control was applied. The power requirements and power consumption were used as metrics to compare the power efficiency in $2{\times}2$ STBC-VLC environments under the three kinds of modulation. We confirm that dimming control affects the communications performance of each modulation scheme. VPPM showed greater consumption among the three modulations, and OPPM showed energy savings comparable to VPPM.

Cutting Property Analysis of Paprika for Development of Paprika Auto-Harvester (파프리카 자동수확기 개발을 위한 파프리카의 절단 특성 측정)

  • Lee, Bong Ki;Hwa, Ji Ho;Lee, Dae Weon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.55-55
    • /
    • 2017
  • 본 연구는 파프리카를 자동 수확하기 위한 시스템 개발의 일환으로 수확작업기의 절단장치를 설계하고자 파프리카 과병의 절단특성을 분석하고자 하였다. 파프리카 과병의 절단특성을 분석하기 위하여 사용한 파프리카는 경기도 평택시에서 재배된 파프리카를 사용하였다. 적색 품종인 Nagano RZ와 황색 품종인 Helsinki, 주황색 품종인 Boogie를 사용하였다. 파프리카 과병의 절단 특성을 분석하기 위하여 상기 세 가지 품종의 파프리카 30개씩 총 90개의 파프리카를 사용하여 과병의 중앙 지점을 절단하였다. 절단 특성을 측정하기 위하여 push-pull gauge인 digitect dtg-20을 사용하였으며, 파프리카의 과병의 절단 특성을 측정하기 위하여 일반 농가에서 사용하는 접도 OLFA CK2의 접도의 칼날을 digitect dtg-20에 장착하여 측정하였다. 파프리카 과병의 절단 특성의 시험 항목은 절단강도를 측정하였다. 파프리카의 과병의 절단 특성 측정은 수확작업기의 파프리카 과병의 절단을 위한 절단장치의 설계를 위하여 진행하였다. 파프리카 과병의 절단 특성은 파프리카의 훼손을 최소화한 수확작업을 위한 중요한 요소이다. 파프리카의 과병의 중앙을 절단하여 절단강도와 절단력을 측정하였다. 그 결과 파프리카 과병의 절단강도는 $4.18{\pm}1.18kgf$로 나타났으며, 최대값은 6.91kgf, 최소값은 2.26kgf로 나타났다. 파프리카 과병은 측정된 절단강도의 최대값인 6.91kgf보다 큰 힘을 이용하여 절단하여야 하므로 그에 맞게 수확작업기의 절단장치의 모터를 선정하고 설계가 이루어져야 한다고 판단한다.

  • PDF

Durability Evaluation of ER Fluids in Hydraulic Control Systems (유압제어시스템 적용을 위한 ER 밸브의 내구성 평가)

  • Kim, Do-Tae;Jang, Sung-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

Tn5 lac Mediated Mutagenesis of Enterobacter sp. B54 Antagonistic to Phytophthora capsici. (Phytophthora capsici의 성장을 저해하는 Enterobacter sp. B54의 선발과 Tn5 lac을 이용한 돌연변이 유기)

  • Yoon, Sang-Hong;Choi, Chung
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.5
    • /
    • pp.393-399
    • /
    • 1998
  • Enterobacter sp.B54 which shows antagonistic activity to Phytophthora capsici on potato dextrose agar was selected among 112 strains isolated from Korean soil. After Tn5 lac-induced mutants were obtained through Pl :: Tn5 lac mutagenesis, 2 mutants for loss of antibiosis and 1 mutant for increased antibiosis were screened by using in vitro fungal inhibition assay. When the 3 mutants affected in antibiosis were analyzed by southern hybridization with pRZ102 (ColEl :: Tn5) as a probe, its results suggest that Tn5 lac was randomly inserted into different chromosomal sites in these mutants.

  • PDF

Vertical coherence functions of wind forces and influences on wind-induced responses of a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.;Ding, Q.S.
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.119-158
    • /
    • 2015
  • The characteristics of the coherence functions of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on the Shanghai World Trade Centre - a 492 m super-tall building with section varying along height are studied via a synchronous multi-pressure measurement of the rigid model in wind tunnel simulating of the turbulent, and the corresponding mathematical expressions are proposed there from. The investigations show that the mathematical expressions of coherence functions in across-wind and torsional-wind directions can be constructed by superimposition of a modified exponential decay function and a peak function caused by turbulent flow and vortex shedding respectively, while that in along-wind direction need only be constructed by the former, similar to that of wind speed. Moreover, an inductive analysis method is proposed to summarize the fitted parameters of the wind force coherence functions of every two measurement levels of altitudes. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well. Later, the influences of coherence functions on wind-induced dynamic responses are analyzed in detail based on the proposed mathematical expressions and the frequency-domain method of random vibration theory.

Power spectra of wind forces on a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.295-320
    • /
    • 2014
  • The characteristics of amplitudes and power spectra of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on a 492 m high-rise building with a section varying along height in typical wind directions are studied via a rigid model wind tunnel test of pressure measurement. Then the corresponding mathematical expressions of power spectra of X axial (across-wind), Y axial (along-wind) and torsional wind forces in $315^{\circ}$ wind directions are proposed. The investigation shows that the mathematical expressions of wind force spectra of the main structure in across-wind and torsional directions can be constructed by the superimposition of an modified wind spectrum function and a peak function caused by turbulent flow and vortex shedding, respectively. While that in along-wind direction can only be constructed by the former and is similar to wind spectrum. Moreover, the fitted parameters of the wind load spectra of each measurement level of altitude are summarized, and the unified parametric results are obtained. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well.

A Study on the Control Characteristics of ER Valve-FHA System and Durability Test

  • Jang Sung-Cheol;Chang Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1621-1631
    • /
    • 2005
  • In this paper, making the best use of the features of the electro-rheological (ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power industry. Using the manufactured pressure control valve, a one-link manipulator with FHA (Flexible Hydraulic Actuator) is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller. After having durability test, shear stress increased regularly because of starch particles crushed by pump and particle size that was almost the same. Moreover, Ra of copper electrode increased about 1.56 times rather than before those of performing durability test, and Rz increased about 2.2 times.

Evaluation of Ramp Test Using Human Perception (인지적 평가기준을 이용한 Ramp Test의 특성평가)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.9-14
    • /
    • 2012
  • The objectives of this study were to compare the results of HSL (Health and Safety Laboratory) ramp test with perceived sense of slip onto the several different floor surfaces under contaminated conditions. There are a variety of approaches from biomechanical measurements to psychophysical test and human perception. However, controversies over these approaches still remain. Some widely accepted methods need to be improved. AHP (Analytic Hierarchy Process) was used to evaluate the perception of slipperiness of seven different floor surfaces under the contaminated condition with glycerol solution. Twelve subjects worn same footwear and walked with self-selected step and cadence along the test floors. The angle of inclination obtained for water wet condition using 5 l/min with HSL ramp test was compared to perception of slipperiness. The surface roughness ($R_z$) related very well both AHP (r=0.95) and ramp test (r=0.92). The high significant correlation (r=0.90) was found between AHP and HSL ramp test.The HSL ramp test values (Coefficient of Friction, COF) according to subjective evaluation were divided into two categories. There were high correlations between test results (subjective evaluation, HSL ramp test) and surface roughness in Rz. Perception rating obtained with AHP showed a high correlation with COF obtained with HSL ramp test.

The Influence of the Surface Roughness on the Natural Convection on a Vertical Flat Plate (수직평판의 거칠기가 자연대류 열전달에 미치는 영향)

  • Ohk, Seung-Min;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.21-27
    • /
    • 2014
  • The influence of the surface roughness on the natural convection heat transfers of a vertical plate were measured experimently. Mass transfer experiments instead of heat transfer experiment were performed based on the analogy. The piecewise electrodes were adopted to measure the local-average Nusselt number. Prandtl number was 2,014 and height of the plate was 0.154m The test results for a smooth surface showed similar heat transfer rate with the Le Fevre heat transfer correlation for a vertical plate. The Nusselt number increased with the roughness Rz $0.5{\sim}14.1{\mu}m$. The test results were presented by a simple correlation.