• Title/Summary/Keyword: Run-off water

Search Result 143, Processing Time 0.027 seconds

ENHANCED ARCTIC PRIMARY PRODUCTIVITY FOLLOWING SEA ICE RAPID DECLINE

  • Comiso, Josefino C.
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.1019-1022
    • /
    • 2006
  • Satellite sea ice data from 1978 to the present reveal that the perennial ice (or ice that survives the summer) has been rapidly declining at almost 10% per decade. Warming due to increases in greenhouse gases in the atmosphere is now also being reflected in winter with drastic reductions in the maximum extent observed in 2005 and 2006. The retreat of the perennial ice also exposes more open water and has revealed an asymmetric distribution of chlorophyll a pigment concentration in the Arctic basin. Phytoplankton blooms are most dominant at high latitudes, partly on account of sea ice, but in the Arctic basin, it appears that pigment concentrations in the Eastern (Laptev Sea) Region are on the average three times higher than those in the Western (Beaufort Sea) Region. Such asymmetry suggests that despite favorable conditions provided by the melt of sea ice, there are other factors that affects the productivity of the region. The asymmetry is likely associated with much wider shelf areas in the East than in the West, with sea ice processes that inhibits the availability of nutrients near the surface in deep water regions, and river run-off that affects nutrient availability. The primary productivity in the pan-Arctic region have been estimated using the pigment concentrations and PAR derived from SeaWiFS data and the results show large seasonal as well as interannual variability during the 1998 to 2005 period. The data points towards increasing productivity for later years but with only 9 years of data it is too early to tell the overall effect of the sea ice retreat.

  • PDF

Analysis of Storm Water Run-off Characteristics during Wet Weather (강우시 합류식 하수관거의 유출특성 분석)

  • Choi, Sung-Hyun;Choi, Seung-Chol;Park, Eun-Young;Rim, Jay-Myoung
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.95-101
    • /
    • 2002
  • Much of domestic city is served by combined sewer system rather than separate sanitary or storm sewers. During wet weather, when the volume of sanitary sewage and storm water entering the combined sewers exceeds the system capacity, the system is designed to overflow at several designated CSOs. The objective of this research is to have grasp of characteristics of combined sewer runoff and to evaluate efficiently the intercepted volume of CSOs. During the wet weather in first rainfall, SS load at each site H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, SS load at each site in second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. EMCs at each site were 702mg/L, 816mg/L, 861mg/L in first rainfall and 99.9mg/L, 161.9mg/L, 103.6mg/L in second rainfall, respectively. First flush coefficients b at each site were 0.237, 0.166, and 0.151.

  • PDF

CHARACTERIZATION AND STABILIZATION OF WASTE DUSTS FROM SHREDDED AUTOMOBILES INDUSTRIES

  • Takashi, Furuyama;Abel, Bissombolo;Sukeyuki, Mori;Masamichi, Hata;Yoshitsugu, Koga;Tetsuo, Ikejiri
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.699-704
    • /
    • 2001
  • Until recently, disposal to landfill has been the most convenient way to deal with the increasing amount of residues the shredding industries produce. But the shortage of such disposal sites and the risk that liquid drained from these waste dusts may pollute ground water have increased the environmental pressures to find more effective solutions. The present study is an alternative approach that suggests identifying waste dusts characteristics and selecting an appropriate binder for hazardous materials to reduce the amount of contaminants (mainly lead) that were leaking into the soil. Investigations on the characteristics of automobiles waste dusts show that these materials are composed mainly of cottons and sponge like substances, plastics, rubber, glasses and gravel, metals, and electric wires. Besides, the percentage in weight of organic (inflammable) materials is about 70% and the lead contamination, which has not a ionic but a particulate nature, is particularly remarkable in cottons and sponge like materials. Binding additives such as K-20 and sodium carbonate were not effective but the addition of 5 % of cement (in weight of the investigated sample) followed by a 3-minute stirring and a 4-hour storage could drastically reduce the run off of lead below the maximum authorized level. No addition of water was necessary in this method.

  • PDF

Numerical Analysis and Experiments for the Stratification of the Hot Water Storage (수축열조의 온도 계층화에 대한 수치해석 및 실험적 연구)

  • Yang, Y.S.;Baek, N.C.;Kim, H.J.;Yoo, J.I.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.187-197
    • /
    • 1993
  • In this study, the numerical analysis and experiments of the hot water storage using the thermal stratification techniques were carried out. The CPU time for a typical run of the the thermal stratification up to 900 seconds took one week for a $81{\times}31$ mesh size and 10 days for a $118{\times}31$ mesh size, respectively, for a cylindrical shape of the storage. In the initial stage, the numerical results were in favorable agreement with the experimental results, but it showed that the temperature gradients in the storage decreased gradually with time. It was also found that the increase of ${\delta}t$ decreased the convergent speed due to the intensive fluctuation of the velocity field in every iteration. The increase of numbers of grids is projected to forecast a more accurate result, but it made the computing time longer and woul slow down convergence. At the experiments of the flow visualization, it was confirmed that the thermal stratification was apparently built up due to the installation of diffuser at the lower part of the storage. Thus, the thermal performance of the storage could be improved by installing the diffusers at the inlet and outlet.

  • PDF

Characteristics of Adsorption and Desorption of Metalaxyl in the Green Soil of Golf Course (골프장 그린 토양에서 Metalaxyl의 흡ㆍ탈착 특성)

  • 유병로;정경희
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.227-234
    • /
    • 2002
  • Laboratory experiments were conducted to examine the behavior of metalaxyl in environment which was used as pesticide in green soil of golf course and as functions of the characteristics of adsorption, desorption and degradation in soil texture and organic matter contents. Acid water containing metalaxyl was conducted to evaluate the effects on adsorption, desorption and degradation. The adsorption of metalaxyl played more significant role in organic contents than clay contents, and pH Increases more pH 2.5 than pH 5.6. The desorption of metalaxyl from contaminants soil decreased higher organic contents LS-soil than S-soil, but the desorption amount of metalaxyl increased more pH 5.6 than pH 2.5. The rate of degradation of metalaxyl in green soil environmental increased higher organic contents LS-soil than S-soil and decreased more pH 2.5 than pH 5.6. These results indicated that the behavior of metalaxyl of the green soil was affected the soil texture of the golf course. Increasing of organic contents, the adsorption amount of metalaxyl on soil increased. Moreover the decrease of the pH of solution increased adsorption amounts and decreased desorption amounts. As the results, the transportation of metalaxyl in soil decreased the acidic rates. The acidification of soil by the acid rain increased the adsorption amount of metalaxyl, but the degradation of metalaxyl decreased. Therefore, it is possible to sustain contamination in run-off the stream and ground water by residuals in soil.

Removal Characteristics of Cadmium in Micellar Enhanced Ultrafiltration Using DCA (DCA 미셀을 이용한 한외여과에서 카드뮴의 제거특성)

  • 이호원;김승건;강영주
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.211-218
    • /
    • 2003
  • The removal characteristics of cadmium in micellar enhanced ultrafiltration (MEUF) were investigated by using an anionic biosurfactant, deoxycholic acid (DCA). The ultrafiltration experiments were performed in a batch-type stirred cell. The ultrafiltration membranes used were Millipore YM1, YM3, YM10, and YM30 which had a difference in molecular weight cut-off. The presence of cadmium ion in DCA solution tends to reduce the critical micell concentration considerably and increase the micell size. The molecular weight cut-off of ultrafiltration membrane had a minimal effect on cadmium removal whereas DCA/Cd ratio had a substantial influence. When DCA/Cd ratio was 3, the removal efficiency of cadmium was more than 99.6%. A relative flux, which is defined as ratio of the flux for a separation trial to that of deionized water run using the same piece of membrane, decreased in the order of YM3 > YM1 > YM10 > YM30.

Evaluation of Water Quality Characteristics and Grade Classification of Yeongsan River Tributaries (영산강 수계 지류.지천의 수질 특성 평가 및 등급화 방안)

  • Jung, Soojung;Kim, Kapsoon;Seo, Dongju;Kim, Junghyun;Lim, Byungjin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.504-513
    • /
    • 2013
  • Water quality trends for major tributaries (66 sites) in the Yeongsan River basin of Korea were examined for 12 parameters based on water quality data collected every month over a period of 12 months. The complex data matrix was treated with multivariate analysis such as PCA, FA and CA. PCA/FA identified four factors, which are responsible for the structure explaining 78.2% of the total variance. The first factor accounting 27.3% of the total variance was correlated with BOD, TN, TP, and TOC, and weighting values were allowed to these parameters for grade classification. CA rendered a dendrogram, where monitoring sites were grouped into 5 clusters. Cluster 2 corresponds to high pollution from domestic wastewater, wastewater treatment and run-off from livestock farms. For grade classification of tributaries, scores to 10 indexes were calculated considering the weighting values to 3 parameters as BOD, TN and TP which were categorized as the first factor after FA. The highest-polluted group included 10 tributaries such as Gwangjucheon, Jangsucheon, Daejeoncheon, Gamjungcheon, Yeongsancheon. The results indicate that grade classification method suggested in this study is useful in reliable classification of tributaries in the study area.

Runoff of Trifluralin from Fields in Louisiana (Louisiana의 농장에서 Trifluralin의 유출)

  • ;S.E. Feagley
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.585-592
    • /
    • 1996
  • Trifluralin (2, 6-dinitro-N, N-dipropyl-4- (trifluormethyl) benzenamine) was applied preemergent to soybean in plots drained or nondrained, in louisiana. Plots 14.6 ha were arranged to give 1683 g/ha of trifluralin. The half life of trifluralin in the top 15 cm of soil was 42.6 darts and f6.0 days in nondrained plot and drained plot, respectively. The concentrations of trifluralin in surface runoff water and subsurface runoff water were 0.62 ng/ml-0.02 ng/ml and 11.06 ng/ml-0.02 ng/ml, respectively. The concentration of trifluralin in runoff water was smaller than 2 ng/ml for trifluralin of U.S. Environmental Protection Agency advisory. Total loss of trifluralin in runoff water was 0.021 % of applied amount at drained plots during three month after application. Trifluralin was moved hardly in the water. Subsurface drainage -reduced trifluralin losses because concentration of trifluralin in the subsurface runoff water in drained fields was low.

  • PDF

Evaluating Future Stream Flow by Operation of Agricultural Reservoir Group considering the RCP 8.5 Climate Change Scenario (RCP 8.5 기후변화 시나리오를 고려한 농업용 저수지군 운영에 따른 미래 하천유량 평가)

  • Lee, Jaenam;Noh, Jaekyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.113-122
    • /
    • 2015
  • This study aims to evaluate future stream flow by the operation of agricultural reservoir group at the upper stream of the Miho River. Four agricultural reservoirs with storage capacities greater than one million cubic meters within the watershed were selected, and the RCP 8.5 climate change scenario was applied to simulate reservoir water storage and stream flow assuming that there are no changes in greenhouse gas reduction. Reservoir operation scenarios were classified into four types depending on the supply of instream flow, and the water supply reliability of each reservoir in terms of water supply under different reservoir operation scenarios was analyzed. In addition, flow duration at the watershed outlet was evaluated. The results showed that the overall run-off ratio of the upper stream watershed of the Miho River will decrease in the future. The future water supply reliability of the reservoirs decreased even when they did not supply instream flow during their operation. It would also be difficult to supply instream flow during non-irrigation periods or throughout the year (January-December); however, operating the reservoir based on the operating rule curve should improve the water supply reliability. In particular, when instream flow was not supplied, high flow increased, and when it was supplied, abundant flow, ordinary flow, and low flow increased. Drought flow increased when instream flow was supplied throughout the year. Therefore, the operation of the agricultural reservoirs in accordance with the operating rule curve is expected to increase stream flow by controlling the water supply to cope with climate change.

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.