• Title/Summary/Keyword: Rubber Cord

검색결과 64건 처리시간 0.031초

소염(消炎) 약침(藥鍼)이 대장염 유발 흰쥐의 c-Fos 단백 발현에 미치는 효과 (Pharmacopuncture of Anti-inflammatory Herbal Compounds Suppresses Colon Inflammation-induced c-Fos like Protein Expression in Rats)

  • 송정방;손인철;안성훈;김재효
    • 대한약침학회지
    • /
    • 제13권3호
    • /
    • pp.47-62
    • /
    • 2010
  • Objectives: Colitis is an inflammatory bowel disease characterized by colonic mucosal inflammation and chronic relapsing events represents. The purpose of this study is to evaluate effects of pharmacopuncture of anti-inflammatory herbal compound (AiC) applied to the different acupoints in the acute colitis induced by trinitrobenzenesulphonic acid (TNBS) intracolonic injection in rats. Methods: In Male Sprague - Dawley rats, weighing 250~400g, TNBS (5 mg/kg) was infused intrarectally through a silicon rubber catheter into the anus under isoflurane anaesthesia. Acupoints of LI4 (Hapkok), ST25 (Cheonchu), ST36 (Joksamni), and BL25 (Daejangsu) were intramuscularly injected by AiC, respectively (injection volume & times: 0.2 ml / acupoint, twice times on the 2nd & 3rd day). Expressions of cFos protein in the periaqueductal gray (PAG), locus coeruleus (LC), nucleus of solitary tract (Sol), and the 6th lumbar spinal cord (L6 s.c.) were observed at 24 hr after TNBS induced colitis by immunohistochemistry. Results: The expression of c-Fos protein in the L6 s.c., Sol, LC and PAG increased 24 hr after TNBS injection into colorectum as compared to normal and 50% ethanol treated group. AiC to LI4 inhibited the expression of c-Fos protein in Sol and PAG but not L6 s.c. and LC. AiC to ST36 showed significant inhibition the c-Fos expression in L6 s.c., Sol and PAG. AiC to ST25 only showed the effects in L6 s.c. and PAG. AiC to BL25 inhibited significantly the expression of c-Fos protein all over the areas. To investigate whether or not endogenous opioids are involved, intrathecal injection of naltrexone (30ug/30ul) was applied before the 2nd pharmacopuncture treatment 24 hr after TNBS-induced colitis in rat. Naltrexone reversed the inhibition of c-Fos protein expression in the spinal cord and brainstem. Conclusions: These data show that pharmacopuncture of Aic potently inhibits signal pathways ascending hypersensitivity of colorectum after TNBS induced colitis and depends on the endogenous opioids according to acupoints.

플라즈마 중합 코팅된 타이어 코드의 노화에 따른 접착력 변화 연구 (Study of Aging and Durability on Plasma Polymerized Tire Cords)

  • 강현민;윤태호
    • 접착 및 계면
    • /
    • 제4권1호
    • /
    • pp.28-34
    • /
    • 2003
  • 강철 타이어 코드의 접착력 향상을 위하여 아세틸렌 플라즈마 중합 코팅, 아르곤 에칭+아세틸렌 플라즈마 중합 코팅, 그리고 아르곤 에칭+담채를 이용한 아세틸렌 플라즈마 중합 코팅을 실시하였으며, 접착력은 TCAT시편으로 측정하였다. 플라즈마 중합 코팅된 타이어 코드의 내구성을 고찰하기 위하여 제 1 단계로 아세틸렌 플라즈마 중합 코팅된 타이어코드를 상온에서 1, 3, 5, 10, 15일 동안 방치한 후 TCAT 시편을 제조하여 접착력변화를 측정하였으며, 제 2 단계로는 플라즈마 중합 코팅된 코드로 TCAT 시편을 제조한 후 증류수, 10% NaCl 수용액에서 또는 $100^{\circ}C$ 오븐에서 1, 2, 3, 4주간 노화시키면서 접착력 변화를 측정하였다. SEM/EDX을 이용하여 코드의 파괴표면을 분석하였으며, 황동코팅과 비교 분석하였다. 아르곤 에칭+담채를 이용한 아세틸렌 플라즈마 중합으로 코팅된 강철 타이어 코드의 접착력은 황동코팅된 시편의 접착력과 거의 같은 수준이었다. 타이어 코드의 상온 노화시험에서 황동코팅된 시편이 아세틸렌 플라즈마 중합 코팅된 시편에 비하여 우수 내구성을 보여주었으나, TCAT 시편의 노화에서는 아세틸렌 플라즈마 중합 코팅이 황동코팅에 비하여 우수하거나 비슷한 결과를 보였다.

  • PDF

경근 치료방법 중 지속적 견인요법의 효과에 관한 실험적 연구 (The Experimental Study of the Effects of Continuous Traction Therapy in Meridian Sinews Therapy)

  • 신정훈;황성연;금경수;김재효;손인철;안성훈
    • Korean Journal of Acupuncture
    • /
    • 제29권3호
    • /
    • pp.385-395
    • /
    • 2012
  • Objectives : Meridian sinew theory was introduced in Miraculous Pivot, Huangdi's Internal Classic, to explain in relation with locations of meridian sinews, causes, mechanisms, and treatment of diseases. The meridian sinews are understood to include muscles, tendons and ligaments, or muscles in the superficial body made up with muscles, ligaments, tendons, fascia etc. This theory shows the similarity or organic relationship between the meridian sinews and muscles. From the Hippocrates(460-385 BC) ages, traction therapy was used as a treatment method on muscular diseases such as low back pain, scoliosis, etc in western medicine. The effects of traction therapy, however, were unclear so that this study was purposed to illustrate the effectiveness of continuous traction therapy and to develop meridian sinews treatment. Methods : We made 2 hypotheses to explain the cause of scoliosis occurrence, muscles contraction and relaxation. As the hypothesis, we made the spinal model having 3 joints with wood and rubber bands. Each of the three joints in the spinal model represents the case of normal(NT; control), contraction(AT 1)and relaxation(AT 2) condition, and distance between the vertebrae joints was measured. Results : Under normal circumstance models, the normal type 1(NT 1; muscle relax state) and normal type 2(NT 2; muscle contract state) all joints were being towed equally. But in an unusual contracted situation, regardless of the relationship of joint area, contracted part of joint was not released. And in a relaxed situation, regardless of joint areas, released parts of joint were further released. These observation results mean that the effects of traction might be different from the purpose of traction therapy of Hippocrates. Conclusions : To explain the effect of traction therapy for scoliosis, the spinal cord model and scoliosis model were made. After vertebral bodies were pulled with different tensile forces, we compared the observed length of the each joints pulled. The results suggested that there were no effects of traction in objected parts with traction method from Hippocrates' design, continuous traction method. Moreover, it may worsen the symptom in worst case. Of course, our results are just the result of experimental models and clinical results may be different. More careful studies, therefore, are required.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF