• Title/Summary/Keyword: Rs interface

Search Result 178, Processing Time 0.022 seconds

Asan Medical Center Laboratory Information System (R) Information Communication System for Routine Hematology Using a Down-Sized Computer - (서울중앙병원 임상병리과 정보관리시스템(III))

  • 민원기;최윤미
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.333-340
    • /
    • 1994
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16 MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with two complete blood count analyzers (Sysmex WE-8000 and Coulter STKS) for unidirectional data transmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

Implementation of Lamp Monitoring System(LMS) for Ship Based on PLM (PLM 통신기반 선박용 LMS 구현)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Baek, Young-Jin;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.182-189
    • /
    • 2007
  • This paper describes the implementation of control and monitoring system of ship's lamps at local area using power line communication method, power line modem(PLM). We design modem, microprocessor interface for electric power control by frequency control and analog to digital signal conversion, lamp device. PLM communication is very economical using existing electric power line unlike RS-232, RS-485 communications. We verify and confirm by experimental work that control and monitor lamp system for ship by an PLM communication.

Development of the Intelligent Multi-Casting System (지능형 멀티 캐스팅 방송 시스템의 개발)

  • Lim Chan-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.10 no.4
    • /
    • pp.90-96
    • /
    • 2005
  • This paper develops a multi-casting system could be used in a school and hospital and government and municipal public offices. The developed multi-casting system uses various educational multimedia titles effectively and is capable of remote control by using a network(LAN). The developed system includes speaker control module that make individual or group broadcasting, AV contents control module for using a diverse educational multimedia title effectively and light control module. The system uses RS-485C communication module and the effective control system interface based on GUI.

  • PDF

Internet Web-Based Rectifier Remote Control System Using SNMP (인터넷 웹 기반 환경에서의 정류기용 원격 제어 시스템)

  • Choi, Ju-Yeop;Oh, Young-Eun;Jeon, Ho-Suk;Song, Joong-Ho;Choi, Ik
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.88-92
    • /
    • 1999
  • This paper aims at developing remote contro system to control and monitor distributed various devices through internet or information communication network. SNMP (Simple Network Management Protocol) and rectifier operated in a row are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time java-environment software is constructed. Also general-use interface controller between network device and applied device is proposed. Finally, seria communication such as RS-232 and RS-485 is used between controller and applied device.

  • PDF

Estimating Pollutant Loading Using Remote Sensing and GIS-AGNPS model (RS와 GIS-AGNPS 모형을 이용한 소유역에서의 비점원오염부하량 추정)

  • 강문성;박승우;전종안
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.102-114
    • /
    • 2003
  • The objectives of the paper are to evaluate cell based pollutant loadings for different storm events, to monitor the hydrology and water quality of the Baran HP#6 watershed, and to validate AGNPS with the field data. Simplification was made to AGNPS in estimating storm erosivity factors from a triangular rainfall distribution. GIS-AGNPS interface model consists of three subsystems; the input data processor based on a geographic information system. the models. and the post processor Land use patten at the tested watershed was classified from the Landsat TM data using the artificial neural network model that adopts an error back propagation algorithm. AGNPS model parameters were obtained from the GIS databases, and additional parameters calibrated with field data. It was then tested with ungauged conditions. The simulated runoff was reasonably in good agreement as compared with the observed data. And simulated water quality parameters appear to be reasonably comparable to the field data.

Internet Web-Based Remote Control System Using SNMP (인터넷 웹 기반 환경에서의 원격 제어 시스템)

  • Choi, Ju-Yeop;Oh, Young-Eun;Jeon, Ho-Seok;Song, Joong-Ho;Choy, Ick
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3159-3161
    • /
    • 1999
  • This paper aims at developing remote control system to control and monitor distributed various devices through internet or information communication network. SNMP (Simple Network Management Protocol) and UPS (Uninterruptible Power Supply) are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, Java-environment software is constructed. Also, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232 and RS-485 is used between controller and applied device.

  • PDF

A Development of Energy Saving System for Automatic Lighting Control using PIR (PIR을 이용한 에너지절감형 자동조명제어 시스템 개발)

  • Joo, Jin-Hwan;Kang, Shin-Wook;Kwon, Hak-Cheol;Lee, Suk-Gyu;Park, Ju-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.58-68
    • /
    • 2010
  • This paper proposes a novel design of auto light control system with high efficiency using RS-485 to save lighting energy in new and existing buildings. The proposed system consists of ALSU(Auto Light Sensor Unit) which is connected with RS-485 to control lighting appliances, ALS(Auto Light Unit), and Hi-FACS which is a monitoring system using communication interface. lighting appliances are automatically controlled by ALSU which detects moving objects. The total system is designed to be controlled by either manual or auto mode by using the ALS. In addition, the monitoring system receives the information on the state of the lighting appliances from ALSU and ALS to control the proposed system We compared the proposed system with the conventional one in functionality and energy saving point of view. Through some experimental results, the proposed system shows better performance in various circumstances.

Integrated Middleware for Real-Time Device Drivers on Windows (윈도우즈 상에서 실시간 디바이스 드라이버를 위한 통합 미들웨어)

  • Jo, Ah-Ra;Song, Chang-In;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.22-31
    • /
    • 2013
  • For the case of test equipments requiring data accuracy, real-time is highly required in acceptance test for performance evaluation of developed weapons. For convenience' sake, test equipments are usually developed using Windows. However Windows does not support real-time in itself. Thus, in this paper, so as to reduce development time and expenses, we design and implement an integrated middleware for real-time device drivers using RTiK-MP. Using DLL, we also support user API's for the sake of development convenience without details of the complex RTiK-MP structure. We evaluate the performance of the proposed integrated middleware using the RDTSC command which returns the number of CPU clock ticks. The evaluation results show that it operates correctly within error ranges in the periods of 1ms and 4ms for the cases of TCP/IP and RS-232, respectively.

PWM ASIC Development for AC Servo and Spindle motor control (AC Motor 제어용 PWM ASIC 설계 및 개발)

  • 최종률
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.605-609
    • /
    • 2000
  • This paper presents a development of the Pulse Width Modulation ASIC for control of the AC servo or spindle motor in machine tools. The ASIC is designed two PWM functions for simultaneous control of a converter and an inverter. Also the device includes additionally two UART functions for interfacing the RS232C with PC or other devices. The device is connected to the microprocessor of Intel or Motorola by bus interface. The required output voltage and frequency for the motor control is programmed to the PWM block and the corresponding switching signals are calculated and generated with regard to the programmed value.

  • PDF

Design of color graphic monitoring system (공정 감시를 위한 Software의 개발)

  • 가민호;임준홍;조영조;김광배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.364-369
    • /
    • 1992
  • 본 논문에서는 연속 공정자동화를 위한 시스템 제어장치 중 공정의 제반운영 및 제어상태를 감시하기 위하여 공정상태를 나타내는 여러가지의 data를 그래픽 모니터상에 graphics로 표시해 주는 User Interface System인 Operator Terminal의 설계 및 구현을 다룬다. 이를 위하여 Operator Terminal은 출력장치로 VGA board와 color monitor, 입력장치로는 mouse와 function keyboard, 통신을 위한 RS232C serial port를 갖는 IBM-PC AT급의 mother board로 구성된다. 또한 program 저장은 상위 computer의 HDD를 이용한다. 그래픽 편집 및 모니터링을 위한 software는 한글 MS Windows 환경에서 구현한다.

  • PDF