• Title/Summary/Keyword: Routine Individual Monitoring

Search Result 14, Processing Time 0.026 seconds

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

Postpartum Reproductive Management Based on the Routine Farm Records of a Dairy Herd: Relationship between the Metabolic Parameters and Postpartum Ovarian Activity

  • Takagi, Mitsuhiro;Hirai, Toshiya;Moriyama, Naoki;Ohtani, Masayuki;Miyamoto, Akio;Wijayagunawardane, Missaka P.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.787-794
    • /
    • 2005
  • The aim of this study was 1) to confirm the practical efficiency of a routine milk P4 monitoring system for postpartum reproductive management of a dairy herd, and 2) to evaluate the relationship between the blood metabolic profiles, milk quality and body weight of individual cows in the farm records, which may reflect the postpartum nutritional condition, and the time of postpartum resumption of ovarian activity of dairy cows. A total of 116 Holstein cows was used in the present study. First, during the period of Experiment 1, postpartum reproductive management based on weekly measured milk P4 concentration from individual cows was conducted. Compared with the reproductive records of the past two years without P4 monitoring, although the day from calving to first AI did not change, both the number of AI until pregnant (with P4; 1.9 times vs. without P4; 2.9 times) and the days open (with P4; 95.1 days vs. without P4; 135.8 days and 133.8 days) were significantly decreased. In Experiment 2, the measurement of blood constituents such as albumin, blood urea nitrogen, packed cell volume, ammonia, glucose, total cholesterol, non-esterified, AST and $\gamma$-GTP was performed on the blood samples taken once approximately 14 days postpartum, to monitor both health and nutritional conditions. The milk constituent parameters, such as milk protein (MP), milk fat (MF), SNF and lactose, collected from the monthly progeny test of individual cows, were used to monitor the postpartum nutritional status. Furthermore, the data obtained from the routine measurements of body weight were used to calculate the rate of peripartum body weight loss. The resumption day of the postpartum estrous cycle was assumed from the milk P4 profiles of individual cows. There was no clear relationship between each parameter from blood examination and those from resumption time. However, the cows had low values of MP, and SNF, which significantly affected the resumption of the postpartum estrous cycle. Similarly, a higher rate of body weight loss indicated a significant delay (more than 1 month) in the resumption of the postpartum estrous cycle, compared with the groups that had a medium or lower rate of body weight loss. The results of the present study demonstrated that the implementation of routine milk P4 monitoring-based postpartum reproductive management, together with milk quality parameters and routine BW data available in field conditions may be utilized as a practical approach for increasing the postpartum reproductive efficiency of a high yielding dairy herd.

Imperceptible On-Skin Sensor Devices for Musculoskeletal Monitoring and Rehabilitation (상시 근골격 모니터링과 재활을 위한 온스킨 센서 디바이스 기술)

  • Park, C.W.;Koo, J.B.;Jin, H.;Kim, Y.;Lim, C.;Hong, C.H.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.2
    • /
    • pp.30-41
    • /
    • 2022
  • As the society is superaging, the number of patients with movement disabilities due to musculoskeletal or nervous system illness is rapidly increasing. To improve public health and reduce medical expenses, it is essential to develop rehabilitation systems that allow patients to resume their daily-life activities. However, the existing musculoskeletal illness diagnosis and rehabilitation method is limited in terms of precision and efficiency because it is based on an empirical diagnosis and prescription without regard for individual characteristics. To overcome these limits, it is critical to design a novel concept of routine rehabilitation therapy device that is capable of inducing musculoskeletal balance by the precise analysis of musculoskeletal usage patterns via the motion and the muscle activity tracking of linked muscles. This study introduces the trend of on-skin sensor device technology for routine musculoskeletal monitoring and therapy. For on-skin rehabilitation systems, skin-adhesive and stretchable motion/posture, electromyography, pressure sensors, small-size and low-power wireless sensor interfaces, and user-friendly rehabilitation contents based on new algorithms are combined.

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

Using multiple sequence alignment to extract daily activity routines of the elderly living alone

  • Lee, Bogyeong;Lee, Hyun-Soo;Park, Moonseo;Ahn, Changbum Ryan;Choi, Nakjung;Kim, Toseung
    • Advances in Computational Design
    • /
    • v.4 no.2
    • /
    • pp.73-90
    • /
    • 2019
  • The growth in the number of single-member households is a critical issue worldwide, especially among the elderly. For those living alone, who may be unaware of their health status or routines that could improve their health, a continuous healthcare monitoring system could provide valuable feedback. Assessing the performance adequacy of activities of daily living (ADL) can serve as a measure of an individual's health status; previous research has focused on determining a person's daily activities and extracting the most frequently performed behavioral patterns using camera recordings or wearable sensing techniques. However, existing methods used to extract common patterns of an occupant's activities in the home fail to address the spatio-temporal dimensions of human activities simultaneously. Though multiple sequence alignment (MSA) offers some advantages - such as inherent containment of the spatio-temporal data in sequence format, and rapid identification of hidden patterns - MSA has rarely been used to extract in-home ADL routines. This research proposes a method to extract a household occupant's ADL routines from a cumulative spatio-temporal data log of occupancy collected using a non-intrusive method (i.e., a tomographic motion detection system). The findings from an occupant's 28-day spatio-temporal activity log demonstrate the capacity of the proposed approach to identify routine patterns of an occupant's daily activities and to reveal the order, duration, and frequency of routine activities. Routine ADL patterns identified from the proposed approach are expected to provide a basis for detecting/evaluating abrupt or gradual changes of an occupant's ADL patterns that result from a physical or mental disorder, and can offer valuable information for home automation applications by enabling the prediction of ADL patterns.

Initial development of wireless acoustic emission sensor Motes for civil infrastructure state monitoring

  • Grosse, Christian U.;Glaser, Steven D.;Kruger, Markus
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.197-209
    • /
    • 2010
  • The structural state of a bridge is currently examined by visual inspection or by wired sensor techniques, which are relatively expensive, vulnerable to inclement conditions, and time consuming to undertake. In contrast, wireless sensor networks are easy to deploy and flexible in application so that the network can adjust to the individual structure. Different sensing techniques have been used with such networks, but the acoustic emission technique has rarely been utilized. With the use of acoustic emission (AE) techniques it is possible to detect internal structural damage, from cracks propagating during the routine use of a structure, e.g. breakage of prestressing wires. To date, AE data analysis techniques are not appropriate for the requirements of a wireless network due to the very exact time synchronization needed between multiple sensors, and power consumption issues. To unleash the power of the acoustic emission technique on large, extended structures, recording and local analysis techniques need better algorithms to handle and reduce the immense amount of data generated. Preliminary results from utilizing a new concept called Acoustic Emission Array Processing to locally reduce data to information are presented. Results show that the azimuthal location of a seismic source can be successfully identified, using an array of six to eight poor-quality AE sensors arranged in a circular array approximately 200 mm in diameter. AE beamforming only requires very fine time synchronization of the sensors within a single array, relative timing between sensors of $1{\mu}s$ can easily be performed by a single Mote servicing the array. The method concentrates the essence of six to eight extended waveforms into a single value to be sent through the wireless network, resulting in power savings by avoiding extended radio transmission.

Analysis of Problems of Food Service Establishments Contributing to Food Poisoning Outbreaks Discovered through the Epidemiological Studies of Some Outbreaks (식중독 발생의 사례 통해 본 집단급식의 문제접 분석)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.240-253
    • /
    • 1997
  • The main problems contributing to food poisoning outbreaks in institutional settings and a home were reviewed and analyzed through the epidemiological investigations of food poisoning. The major documented factors included improper holding temperatures, inadequate cooking, poor personal hygiene, cross-contamination and contaminated equipment, food from unsafe sources, failure to follow food hygiene policies, and lack of education, training, monitoring and superivision. Usually more than one factor contributed to the development of an outbreak. (1) Use of improper holding temperatures was the single most important factor contributing to food poisoning. They included improper cooling, allowing a laps of time (12 hours or more) between preparing food and eating it, improper hot holding, and inadequate or improper thawing. Food thermometers were not used in most of the instances. (2) In inadequate cooking, the core temperature of food during and after cooking had not been measured, and routine monitoring was limited to recording the temperature of plated meals. Compared with conventional methods of cooking, microwave ovens did not protect against food poisoning as effectively. Centralized food preparation potentially increased the risk of food poisoning outbreaks. (3) Poor personal hygiene both at the individual level (improper handwashing and lack of proper hygienic practices) and at the institutional level (poor general sanitization) increased the risk of transmission. Person to person transmission of enteric pathogens through direct contact and via fomites has been noted in several instances. (4) Obtaining food from unsafe sources was a risk factor in outbreaks of food poisoning. Food risks were high when food was grown or harvested from contaminated areas. Possibilities included contamination in the field, in transport, at the retail site, or at the time it was prepared for serving. (5) Cross-contamination and inadequate cleaning/handling of equipment became potential vehicles of food poisoning. Failure to separate cooked food from raw food was also a risk factor. (6) Failure to follow food hygiene policies also provided opportunities for outbreaks of food poisoning. It included improper hygienic practices during food preparation, neglect of personnel policies (involvement of symptomatic workers in food preparation), poor results on routine inspections, and disregarding the results and recommendations of an inspection. (7) Lack of formal and in-service education, training, monitoring, and supervision of food handlers or supervisors were critical and perhaps neglected elements in occurrences of food poisoning.

  • PDF

Clinical Pharmacology of Mycophenolic Acid as Immunosuppressant in Organ Transplaantation

  • Kang, Ju-Seop;Lee, Joo-Won;Jhee, Ok-Hwa;Om, Ae-Son;Lee, Min-Ho;Shaw, Leslie M.
    • Biomolecules & Therapeutics
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2005
  • Present article reviews about clinical pharmacology of mycophenolic acid (MPA), the active form of mycophenolate mofetil (MMF), as widely used component of immunosuppressive regimens in the organ transplantation field. MMF, used alone or concomitantly with cyclosporine or tacrolimus, has approved in reducing the incidence of acute rejection and has gained widespread use in solid organ such as kidney, heart and liver transplantation. The application of MPA and development of MMF has shown a considerable impact on immunosuppressive therapy for organ transplantation as a new immunosuppressive agent with different mechanism of action from other drugs after early 1990s. In particular aspect, use of MMF, a morpholinoethyl ester of MPA, represented a significant advance in the prevention of organ allograft rejection as well as allograft and patient survival. In considering MMF clinical data, it is important to note that there is a strong correlation between high MPA area under curve(AUC) values and a low probability of acute allograft rejection. Individual trials have shown that MMF is generally well tolerated and revealed that MMF decreased the relative risk of developing chronic allograft rejection compared with azathioprine. Recent clinical investigations suggested that improved effectiveness and tolerability will results from the incorporation of MPA therapeutic drug monitoring into routine clinical practice, providing effective MMF dose individualization in renal and heart transplant patients. Therefore, MMF has a selective immunosuppressive effect with minimal toxicity and has shown to be more effective that other agents as next step of immunosuppressive agents and regimens that deliver effective graft protection and immunosuppression along with a more favorable side effect.

Dimethylnitrosamine-Induced Reduction in the Level of Poly-ADP-Ribosylation of Histone Proteins of Blood Lymphocytes - a Sensitive and Reliable Biomarker for Early Detection of Cancer

  • Kma, Lakhan;Sharan, Rajeshwar Nath
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6429-6436
    • /
    • 2014
  • Poly-ADP-ribosylation (PAR) is a post-translational modification of mainly chromosomal proteins. It is known to be strongly involved in several molecular events, including nucleosome-remodelling and carcinogenesis. In this investigation, it was attempted to evaluate PAR level as a reliable biomarker for early detection of cancer in blood lymphocyte histones. PAR of isolated histone proteins was monitored in normal and dimethylnitrosamine (DMN)-exposed mice tissues using a novel ELISA-based immuno-probe assay developed in our laboratory. An inverse relationship was found between the level of PAR and period of DMN exposure in various histone proteins of blood lymphocytes and spleen cells. With the increase in the DMN exposure period, there was reduction in the PAR level of individual histones in both cases. It was also observed that the decrease in the level of PAR of histones resulted in progressive relaxation of genomic DNA, perhaps triggering activation of genes that are involved in initiation of transformation. The observed effect of carcinogen on the PAR of blood lymphocyte histones provided us with a handy tool for monitoring biochemical or physiological status of individuals exposed to carcinogens without obtaining biopsies of cancerous tissues, which involves several medical and ethical issues. Obtaining blood from any patient and separating blood lymphocytes are routine medical practices involving virtually no medical intervention, post-procedure medical care or trauma to a patient. Moreover, the immuno-probe assay is very simple, sensitive, reliable and cost-effective. Therefore, combined with the ease of preparation of blood lymphocytes and the simplicity of the technique, immuno-probe assay of PAR has the potential to be applied for mass screening of cancer. It appears to be a promising step in the ultimate goal of making cancer detection simple, sensitive and reliable in the near future.