• Title/Summary/Keyword: Round Grooves

Search Result 18, Processing Time 0.029 seconds

Design Change of E-EGR Valve to Suppress Carbon Deposit (E-EGR Valve 내부 Carbon Deposit 억제를 위한 형상연구)

  • Lee, Hyun-Chang;Lee, Tae-Gon;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4685-4690
    • /
    • 2010
  • New E-EGR valve design to suppress a carbon deposit causing a trouble in the valve by improving gas flow velocity is proposed. With CFD simulations of various shapes of valve disk and rod, the velocities and quantities of flowing fluid are observed. The proposed unique design of having round grooves on the disk head shows the improved performance of flow velocity about 10 % without sacrificing the flow quantity.

A Investigation into Tool State Monitoring by Sensing Changes according to Groove (홈의 형상에 따른 센서 감지거리 변화를 이용한 공구상태 모니터링에 관한 연구)

  • Son, Gil-Ho;Kim, Mi-Ru;Lee, Seung-Jun;Jeong, Jae-Ho;Lew, Kyung-Hee;Lee, Deug-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.31-39
    • /
    • 2017
  • Research in the machine tool industry has focused on ICT-based smart machines rather than hardware technologies related to machine tools. Real-time tool-status monitoring is representative of this type of technology and has become important for measuring sensors during cutting processes. In this paper, we studied several research areas and used a round bar to conduct fundamental research into the axial displacement of the main spindle of a tool when it was subjected to a machining load. We were able to use the gap sensor to detect the axial displacement indirectly by using grooves with various shapes on the round bar and sensing the gaps between the grooves. We then determined the optimal groove shape for monitoring the tool state.

THREE-BODY ABRASIVE WEAR IN A BALL-CRATERING TEST WITH LARGE ABRASIVE PARTICLES

  • Stachowiak, G.B.;Stachowiak, G.W.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.199-200
    • /
    • 2002
  • Three-body abrasive wear resistance of mild steel, low alloy steel (Bisalloy) and 27%Cr white cast iron was investigated using a ball-cratering test. Glass beads, silica sand, quartz and alumina abrasive particles with sizes larger than $100{\mu}m$ were used to make slurries. It was found that the wear rates of all three materials tested increased with time when angular abrasive particles were used and were rather constant when round particles were used. This increase in wear rates was mainly due to the gradual increase in ball surface roughness with testing time. Abrasive particles with higher angularity caused higher ball surface roughness. Mild steel and Bisalloy were more affected by this ball surface roughness changes than the hard white cast iron. Generally, three-body rolling wear dominated. The contribution of two-body grooving wear increased when the ball roughness was significant. More grooves were found when round particles were used or the size of the particles was decreased.

  • PDF

Finite Element Analysis of Externally Round Grooved Profile Ring Rolling Process (외부에 둥근 흠이 있는 형상환상압연공정의 유한요소해석)

  • 김광희;김병탁;석한길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.164-167
    • /
    • 2003
  • Profile ring rolling process is simulated by using the general purpose commercial finite element analysis software MSC.Superform Because the deforming region is restricted to the vicinity of the roll gap, only a ring segment spanning the roll gap is analysed in order to save computation time and cost. A profile ring with an external round groove is chosen as an example to be analysed. The rolls with and without groove were analysed to compare the amount of side spread. It is found that the grooves in the rolls reduce the amount of side spread.

  • PDF

Finite Element Analysis of Externally Round Grooved Profile Ring Rolling Process (외부에 둥근 홈이 있는 형상환상압연공정의 유한요소해석)

  • 김광희;김병탁;석한길
    • Transactions of Materials Processing
    • /
    • v.12 no.7
    • /
    • pp.631-639
    • /
    • 2003
  • Ring rolling process is simulated by using the general-purpose commercial finite element analysis software, MSC.Superform. Because the deforming region is restricted to the vicinity of the roll gap, only a ring segment spanning the roll gap is analyzed in order to save computation time and cost. First, a plain ring rolling of rectangular cross-section is simulated. Comparisons between computation and experiment show good agreement in the cross-sectional configuration of the deformed ring. Then, a profile ring with an external round groove is analyzed. The rolls with and without groove have been analyzed to compare the amount of side spread. It is found that the grooves in the rolls are effective in reducing the amount of side spread.

Fine Needle Aspiration Cytology of Chondroblastoma Arising in the Rib - Report of A Case - (늑골에 발생한 연골아세포종의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Kwon, Kye-Hyun;Jin, So-Young;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.1
    • /
    • pp.61-64
    • /
    • 1994
  • Chondroblastoma is a benign bone tumor accounting for less than 1 % of bone tumor. It infrequently involves the flat bones, among which ribs are particularly rare. On fine needle aspiration cytology, the diagnostic smear consists of chondroblasts, osteoclast-like giant cells, and chondroid matrix. The cytologic hallmark to differentiate from other giant cell-containing lesions is chondroblasts. We experienced a case of chondroblastoma in a 13-year-old female. Fine needle aspiration cytology from the 5 th rib revealed dispersed chondroblasts and osteoclast-like giant cells on hemorrhagic background. Chondroblasts had round to oval nuclei with fine, evenly distributed chromatin and distinctive grooves or indentation. Their cytoplasm was well-defined.

  • PDF

FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO CAVITY DESIGN OF CLASS V COMPOSITE RESIN FILLING (5급와동의 복합레진 충전에 관한 유한요소법적 응력분석)

  • Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun;Cho, Byeong-Hoon;Rim, Young-Il
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.67-75
    • /
    • 1999
  • The use of composite restorative materials is established due to continuing improvements in the materials and restorative techniques. Composite resins are widely used for the restoration of cervical lesions because of esthetics, good physical properties and working time. There are several types of cavity design for class V composite resin filling, but inappropriate cavity form may affect bonding failure, microleakage and fracture during mastication. Cavity preparations for composite materials should be as conservative as possible. The extent of the preparation is usually determined by the size, shape, and location of the defect. The design of the cavity preparation to receive a composite restoration may vary depending on several factors. In this study, 5 types of class V cavity were prepared on each maxillary central incisor. The types are; 1) V-shape, 2) round(U) shape, 3) box form, 4) box form with incisal bevel and 5) box form with incisal bevel and grooves for axial line angles. After restoration, in order to observe the concentration of stress at bonding surfaces of teeth and restorations, developing a 2-dimensional finite element model of labiopalatal section in tooth, surrounding bone, periodontal ligament and gingiva, based on the measurements by Wheeler, loading force from direction of 45 degrees from lingual side near the incisal edge was applied. This study analysed Von Mises stress with SuperSap finite element analysis program(Algor Interactive System, Inc.). The results were as follows : 1. Stress concentration was prevalent at tooth-resin bonding surface of cervical side on each model. 2. In model 2 without line angle, stress was distributed evenly. 3. Preparing bevel eliminated stress concentration much or less at line angle. 4. Model with round-shape distributed stress concentration more evenly than box-type model with sharp line angle, therefore decreased possibility of fracture. 5. Adding grooves to line angles had no effect of decreasing stress concentration to the area.

  • PDF

Crush Cytology Features and Differential Diagnosis of Meningiomas and Schwannomas in Central Nervous System (중추신경계 수막종과 신경초종의 압착도말 세포학적 소견 및 감별진단)

  • Kim, Young-Ju;Jeon, Mi-Yeong;Yang, Young-Il;Kim, Chan-Hwan;Yoon, Hae-Kyoung;Khang, Shin-Kwang
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.169-176
    • /
    • 1996
  • This study was peformed in order to evaluate the usefulness of the crush cytologic features and differential diagnosis between meningiomas and schwannomas in the central nervous system. Deeply seated and unusually located meningiomas and schwannomas with equivocal or erroneous frozen section diagnosis can be correctly diagnosed cytologically in crush preparations. Twenty-four meningiomas and nine schwannomas were studied by frozen section and crush preparation technique. These tumors displayed distinctive cytologic features. in meningiomas, the tumor tissue fragments were easy to crush, and the tumor cells were arranged in small clusters, flat sheets, papilla-like, whorling pattern or singly. Individual tumor cells displayed round or oval nuclei with finely granular chromatin pattern and inconspicuous small nucleoli. Occasionally psammoma bodies, nuclear pseudoinclusion or nuclear grooves were found. In schwannomas, tissue fragments were hard in consistency and difficult to crush. The crushed tissue presented as thick, irregular fragments with shard borders. The cells showed ill-defined cytoplasm and round, oval, cigar-shaped or curved nuclei. It is important to emphasize that the smear pattern under low-power view and cytologic features are helpful in discriminating between these two tumors.

  • PDF

Effect of Application of Tetracycline - HCl on Implant Surface;Scanning Electron Microscopic Study (염산테트라싸이클린이 임플란트 표면에 미치는 효과;주사전자현미경적 연구)

  • Hong, Jung-Ah;Herr, Yeek;Lee, Man-Sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.333-344
    • /
    • 2001
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface and titanium plasma-sprayed surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline - HCl solution for 1 min., $1\frac{1}{2}\;min$., 2 min., $2\frac{1}{2}\;min$. and 3min. respectively in the test group and with saline for 1 min. in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Pure titanium machined surfaces conditioned with saline for 1 min., showed a few shallow grooves and ridges and were less irregular. 2. Pure titanium machined surfaces conditioned with 50mg/ml tetracycline - HCl solution showed more irregular and corrosive surfaces compared to the control group irrespective of the application time of tetracycline - HCl solution. 3. Titanium plasma-sprayed surfaces conditioned with saline for 1 min., were deposited with round amorphous particles and showed round or irregular pores that can be connected to each other. 4. The irregularity of titanium plasma-sprayed surfaces conditioned with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. 5. Titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution for 1 min. and $1\frac{1}{2}\;min$. were very similar to that of the control group, but the surfaces conditioned for 2 min., $2\frac{1}{2}\; min$. and 3 min. were changed. In conclusion, pure titanium machined surfaces were changed irrespective of the application time of tetracycline - HCl solution. And titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution began to be changed from $1\frac{1}{2}\;min$. This results will be applicable to the regenerative procedures for peri-implantitis treatment.

  • PDF

The Bone Formation Potency on the Titanium Cap According to the Pore on the Rabbit Calvarium (가토의 두개골에서 Pore의 유무에 따른 티타늄 반구에서의 골형성 능)

  • Park, Jung-Pyo;Oh, Chul-Jung;Jung, Seunggon;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kook, Min-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: This study is performed to determine the effects of titanium cap with various sizes of pores on bone formation during guided bone regeneration (GBR). Methods: Calvaria from 10 adult male rabbits were chosen as the recipient sites. A trephine bur with a diameter of 10 mm was used to form one round groove on each side of sagittal suture of the cranium, and a round bur with a diameter of 1.5 mm was used to form 6 small holes on the inner circles of round grooves to induce bleeding. In the control group, bone graft was not conducted, and closed titanium cap was fixed in the round groove. Bone graft was not performed in groups 1 and 2, but fixed on titanium caps with 0.2 mm, and 0.5 mm sized pores, respectively. For groups 3, 4, and 5, a synthetic bone graft material (${\beta}$-tricalcium phosphate, Cerasorb$^{(R)}$, Germany) was transplanted, and titanium caps without pore, with 0.2 mm and 0.5 mm sized pore were fixed, respectively. The animals were sacrificed 4 weeks after, and clinical, radiographical, and histomorphometrical evaluation of bone regeneration was performed. Results: In all groups, there were no clinical signs of infection, inflammation or wound dehiscence. Radiographic evaluation revealed well-defined semi-circular radiopacity inside the titanium cap of groups 3, 4, and 5. Histologically, the inner surface of the hemisphere was evenly lined with newly formed bone tissue, as well as grafted bone material in the group 3. In groups 4 and 5, the insertion of connective tissue was observed along the inner surface. However, the overall surface area between the grafts with different holes yielded no statistical significance in the histomorphometrical evaluation. Conclusion: Although the total area of newly formed bone showed no significant difference, excellent bone formation tendency was observed histologically when closed caps were used with bone graft was accompanied.