• Title/Summary/Keyword: Roughness control

Search Result 537, Processing Time 0.028 seconds

Optical Application of Diamond Turning Process (광학 응용을 위한 다이아몬드 터닝 가공)

  • 이봉주;김대중;정상화;박순섭;김상석;김정호;유영문;김주하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1881-1884
    • /
    • 2003
  • Diamond turning machines have, been used for the processing of surface like a mirror with the control scheme of minimizing shape error, Ultra-precision diamond fuming is applied to produce highly precision optical components required not only a high machining accuracy but also a good surface roughness. Al-6061 is widely used as optical parts such as laser reflector's mirror or multimedia instrument. In this study, thermal-imaged Al flat mirrors are fabricated by SPDT. The surface roughness 3.472 nm Ra, power 2 fringe(at 632.8 nm) and irregularity 1 fringe(at 632.8 nm) for form waviness of thermal-imaged Al flat mirror are very satisfied to the required specification in industry.

  • PDF

Micro Machining of Titanium Alloy Using Polycrystalline Diamond Tools (PCD 공구를 이용한 티타늄 합금의 미세 가공)

  • Moon, In Yong;Kim, Bo Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.284-291
    • /
    • 2013
  • Micro cutting of titanium alloy by polycrystalline diamond (PCD) tools was studied. Micro electro discharge machining (MEDM) was used to fabricate customized micro shaping tools from PCD blank. The tool was used to machine micro grooves on Ti alloy and the effects of depth of cut and machining length on tool wear, burr and surface roughness were studied. The shaping tool has cutting edge of a few ${\mu}m$. The crater size of the tool surface was increased with increasing capacitance of EDM machining conditions, which was used to control the surface roughness of the machined micro grooves.

Effect of Coating and Machining Parameters on Surface Finish in Dry Drilling of Aluminium 6061 (Al 6061의 드릴가공에서 공구코팅과 공정변수가 표면정도에 미치는 영향)

  • Choi, Man Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.2
    • /
    • pp.47-52
    • /
    • 2015
  • In this paper, the performance of uncoated- and Titanium nitride aluminium TiAlN-PVD coated- carbide twist drills were investigated when drilling aluminium alloy, Al 6061. This research focuses on the optimization of drilling parameters using the Taguchi technique to obtain minimum surface roughness and thrust force. A number of drilling experiments were conducted using the L9 orthogonal array on a CNC vertical machining center. The experiments were performed on Al 6061 material l blocks using uncoated and coated HSS twist drills under dry cutting conditions. Analysis of variance(ANOVA) was employed to determine the most significant control factors. The main objective is to find the important factors and combination of factors influence the machining process to achieve low surface roughness and low cutting thrust force. From the analysis of the Taguchi method indicates that among the all-significant parameters, feed rate are more significant influence on surface roughness and cutting thrust than spindle speed.

Investigation of Surface Roughness Characteristics according to Tool Runout Variations in Side Milling Cutter for Worm Screw (사이드 밀링 커터를 이용한 워엄 스크루 가공에서 공구 런아웃이 표면조도에 미치는 영향분석)

  • Kim, Sun Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.76-82
    • /
    • 2009
  • A worm screw is widely used in a geared motor unit for motion conversion from rotation to linear motion. For mass production of a high quality worm, the current roll forming process is substituted with the milling cutter process. Since the milling cutter process enables the integration of all machining operations of worm manufacturing on a CNC(Computer Numerical Control) lathe, productivity can be remarkably improved. The tooling system for side milling cutter on the CNC lathe to improve machinability is developed. However, the runout of spindle and cutting tips are important factors to be considered for producing high quality worms because the tooling system has multiple tips. In this study, surface roughness variations accuracy according to runout was investigated in side milling cutter for worm screw. The result shows by simulation and experiment.

  • PDF

A Robust Algorithm for Roughness Laser Measurement based on Light Power Regulation against Specimen Changes

  • Seo Young Ho;Ahn Jung Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1131-1137
    • /
    • 2005
  • Methods for measuring surface roughness based on light reflectivity have advantages over methods based on light interference or diffraction, especially in in-situ, on-the-machine and in-process applications. However, measurement inconsistencies caused by changes in the specimen are still a drawback for field applications. In this study, we propose a new feedback-based algorithm to enhance the consistency against changes in the specimen. The algorithm is deduced from simulations based on light reflectance theory with typical modeled surfaces. The proposed method is similar to a digital controller and regulates the power of reflected light. Experiments varying heights and materials, verified the improvements in robustness of the method against measurement disturbances caused by specimen changes.

Optimization of Process Parameters for AISI 4340 Steel in Electrical Discharge Machining (AISI 4340강의 방전가공에서 공정변수의 최적화)

  • Choi, Man Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.17-22
    • /
    • 2019
  • The method of electrical discharge machining (EDM), one of the processing methods based on non-traditional manufacturing procedures, is gaining increased popularity, since it does not require cutting tools and allows machining involving hard, brittle, thin and complex geometry. This present investigation details the determination of optimum process parameter to attain the better machining performance in EDM of AISI 4340 steel with graphite as a tool electrode. The experimental combinations are planned and analyzed by Taguchi's design of experiments approach. To predict the optimal condition, the experiments are conducted by using Taguchi's L27 orthogonal array. The influence of process variables such as discharge current, pulse on and pulse off time, voltage and spark speed were investigated to control the various desired performance measures such as surface roughness. Analysis of Variance (ANOVA) has to be performed to know the magnitude of each factor. Investigations indicate that the surface roughness is strongly depend on pulsed current.

The effect of conditioning by Tetracycline-Hcl on implant surface;The SEM study and. surface roughness measurements : RBM surface (염산 테트라싸이클린이 RBM적용 임프란트 표면구조에 미치는 영향의 미세구조 및 표면 거칠기 변화에 관한 연구)

  • Lim, Hae-Soo;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.585-597
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for $\frac{1}{2}$min., 1min., $1\frac{1}{2}$min., 2min., $2\frac{1}{2}$min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth

  • Yuzugullu, Bulem;Acar, Ozlem;Cetinsahin, Cem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.333-338
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS. 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal-Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS. A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION. NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth.

The Stereomicroscope and SPM Study on the Marginal Change of Porcelain Crown in Various Repeated Instrumentations for Periodontal Therapy (치주처치를 위한 기구의 반복 사용시 도재관 변연부 변화에 관한 입체 및 주사탐침현미경적 연구)

  • Lee, Si-Cheol;Chung, Chin-Hyung;Yim, Seong-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.455-472
    • /
    • 2000
  • Instrumentation for periodontal therapy may induce marginal damage which increases plaque accumulation and result in periodontal disease. But there have not been many reports of instrumentations on the artificial crown so far. Therefore this study is conducted to evaluate the effects of various repeated instrumentations on the porcelain crown marginal portion. Of the 10 extracted periodontally diseased maxillary first premolars, were 12 proximal surface used in this study. The finishing line of the preparation was placed on the root surface below CEJ and then the crown was cast and cemented in usual manner. Every 4 surfaces of the 3 instruments-curet, ultrasonic scaler, and ultrasonic curet- is used. and four samples used in each instruments. The relevant procedures and measurements were repeated 3 times in each surfaces. Marginal gap is measured by the microscope and surface roughness, Scannig Probe Microscope. Measurements are made at 5 points in each surfaces, making 20 points in each instrument. The results evaluated statistically were as follows 1. As instrumentation was repeated, both marginal gap and roughness were increased in all group 2. In the hand curet, marginal gap was increased every instrumentation and roughness was increased after second. 3. In the ultrasonic scaler, both marginal gap and roughness were increased every instrumentation. 4. In the ultrasonic curet, marginal gap was increased after third instrumentation and roughness was increased after second. 5. Marginal gap and roughness used by the ultrasonic curet were lower than the others and no difference was seen between the hand curet and ultrasonic scaler From the results of this study, the ultrasonic curet was useful in some aspect, but careful instrumentation was needed. Furthermore it was important to minimize the instrumentation through complete periodontal therapy before setting and adequate plaque control.

  • PDF

The SPM Study on the Change of Titanium Surface Roughness following Airpowder Abrasive and Application Time of Citric Acid (공기-분말 연마와 구연산의 적용시간에 따른 임프란트 표면 거칠기의 변화에 관한 주사탐침현미경적 연구)

  • Park, Min-Seo;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.821-836
    • /
    • 2000
  • The Peri-implantitis causes inflammation of periodontal tissue and bone loss. It contaminates surface of implants. Therefore, guided bone regeneration has been used for the treatment of this disease. For the reosseointegration of the exposed surface, various mechanical and chemical methods have been used for cleaning and detoxication of implant surface. Among these methods, air-powder abrasive and oversaturated citrate are known to be most effective. However, these treatments may deform implant surface. In this research, changes of surface roughness they were examined. 10 experimental machined titanium cylinder models were fabricated to be used for control groups. Each of them was air powder abraded for 1 minute and they were named group 1. And then, group 1 were burnished with cotton pellets soaked with citrate for 30 seconds(Group 2), 1 minute(Group 3), 3 minutes(Group 4), and 5 minutes(Group 5) burnishing were applied for grouping respectively. Each group were examined with SPM, and their surface roughness were measured and analyzed. 1. Surface roughness of titanium decreased when it was air-powder abraded for 1 minute. It was statistically significant. 2. When Air-powder abraded titanium were treated with citrate for 3 minutes, Their surface roughness was the lowest. Titanium treated for 1 minute was the second lowest and 30 seconds was the third and titanium burnished for 5 minutes was the highest. 3. Surface roughness of titanium which was treated with citrate was decreased till 3 minutes, which was statistically significant. There was no statistical significance from 30 seconds to 1 minute and from 1 minute to 3 minutes, and there was statistical significance from 30 seconds to 3 minutes. 4. Oxide layer was formed when titanium is exposed to air, and it was removed when air-powder abraded. It was made when treated with citrate. It is thought that citrate treatment is necessary after the air-powder abrasion, and 1 minute is clinically and qualitatively adequate for burnishing time of citrate.

  • PDF