• 제목/요약/키워드: Roughness Pitch Ratio

검색결과 20건 처리시간 0.032초

다구찌 실험 계획법을 활용한 평삭 가공에서의 표면 거칠기에 대한 절삭조건 영향 분석 (Effects of Cutting Parameters on Surface Roughness in Planing Using Taguchi Method)

  • 서동현;권예필;김영재;최환진;전은채
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.93-98
    • /
    • 2021
  • The complex effects of the machining parameters make it is difficult to control and predict surface roughness. The theoretical surface roughness observed during mechanical machining with a round tool is determined by the tool radius and pitch. However, it was revealed that other parameters, such as the depth of cut and cutting speed, also affect surface roughness. This study adapted the Taguchi method, which can analyze the effects of cutting parameters quantitatively with an efficient number of experiments, to optimize the parameters for better surface roughness. Experiments were designed based on an orthogonal array, and the quantitative effects on the surface roughness were analyzed using the S/N ratio. The surface roughness was affected by all parameters, especially the tool radius. The optimum cutting parameter values obtained in this study showed better surface roughness than the other combinations of the parameters.

리브의 높이가 난류 및 열전달특성에 미치는 영향 (Effect of Rib Height on Turbulence and Convective Heat Transfer)

  • 나인;김수진;정효민;정한식;라흐만
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.30-37
    • /
    • 2012
  • Effect of rib heights is found as significant parameter to enhance convective heat transfer performance under laminar and low turbulent regime. Circular ribs with different ribheight to channel height ratios, e/H = 0.05, 0.1, 0.15, are fabricated over the copper substrate respectively in a rectangular duct having 7.5 cross sectional aspect ratio. Only one rib pitch to rib height ratio (P/e = 10) has been chosen for all different height ribs. The result shows that the arithmetic average of turbulence intensity decreases with decreasing roughness height calculated between two ribs under laminar and low turbulent region. It occurs because the area of recirculation and reattachment zone also decreases with decreasing rib height. Optimum thermal enhancement factor is derived by 0.1 rib height to channel height ratio under low turbulent region but 0.15 rib height to channel height ratio gives maximum subjected to laminar flow.

한 측에서만 거칠기가 설치된 삼각덕트의 마찰계수와 열전달 (Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened)

  • 안수환;이영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.17-23
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent flow in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness pitch ratio(P/e) of 4, 8 and 16 on the one side wall only. The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70,000 to 10,000. The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement, measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion, namely, the fin effect. And the results were compared with those of previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

한 측에서만 거칠기가 설치된 삼각덕트의 열전달과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened)

  • 안수환;이영식;이병창
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.65-70
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent f)on· in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness Pitch ratio(P/e) of 4, 8 and 16 on the one side wall only The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70.000 to 10,000 The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement. measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion. namely the fin effect. And the results were compared with those of Previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

거친 사각채널에서 열전달과 유체유동 특성에 관한 실험 및 수치해석 (Experimental and Numerical Investigation on Heat Transfer and Fluid Flow Characteristics in the Ribbed Square Channel)

  • 강호근;배성택;이대희;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.275-283
    • /
    • 2006
  • Experiment and three dimensional numerical investigations of incompressible turbulent flow through square channels with one- and two-sided ribbed walls are performed to determine pressure drop and heat transfer. The CFX(version 5.7) software package is used for the computation. The ribbed walls have a $45^{\circ}$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The numerical results coincide with experimental data that obtained for $7,600{\le}Re{\le}24.900$, the pitch-to-rib height ratio (p/e) of 8.0. and the rib height-to-channel hydraulic diameter ratio ($e/D_h$) of 0.0667. The results show that values of local heat transfer coefficient and friction factor in the channel with two-sided ribbed wall are higher than those in the channel with one-sided ribbed walls.

한 벽면에 V형 리브가 있는 2면 확대 사각채널의 열전달 (Heat Transfer in a Two Wall Divergent Rectangular Channel with V-Shaped Ribs on One Wall)

  • 이명성;안수환
    • 동력기계공학회지
    • /
    • 제19권5호
    • /
    • pp.32-37
    • /
    • 2015
  • The present study is to investigates the convective heat transfer characteristics and pressure drop inside the rib-roughened cooling passage of gas turbine blades. The divergent rectangular channel is fabricated with V-shaped ribs on one wall only and the inlet hydraulic diameter to outlet hydraulic diameter ratio($D_{ho}/D_{hi}$) of 1.49 is used. The current investigation has covered a Reynolds number (Re) range of 22,000~75,000, relative roughness height ($e/D_h$) of 0.1~0.2, and rib angle of attack (a) of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ for a fixed relative pitch of 10. Results show that the Nusselt numbers are the greatest in the $60^{\circ}$-angled ribs; however, the total friction factors are the highest in the $30^{\circ}$-angled ribs.

목사들의 음성발성에 대한 음향분석학적 특징 (Acoustic and Stroboscopic Characteristics in Clergies)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • 대한후두음성언어의학회지
    • /
    • 제9권1호
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF

개수로 측벽 세로돌출줄눈의 흐름저항 (Flow Resistance of Vertical Rib Sidewall in Open Channel)

  • 박상덕;지민규;남아름;우태영;신승숙
    • 한국수자원학회논문집
    • /
    • 제46권9호
    • /
    • pp.947-956
    • /
    • 2013
  • 급경사 산지하천 수충부의 호안은 대부분 콘크리트 옹벽으로 되어있다. 표면이 매끄러운 콘크리트 옹벽호안은 유속을 더 강화시키기 때문에 수충부 홍수피해의 원인이 되기도 한다. 본 연구에서는 개수로의 한 측벽에 설치한 정사각형 단면의 세로돌출줄눈이 흐름저항에 미치는 영향을 파악하기 위해 수리실험을 수행하였다. 돌출줄눈의 설치간격은 무차원 돌출줄눈 간격 ${\lambda}_{nv}$를 기준으로 조도유형 d형과 k형을 포함하도록 설계하였다. 흐름의 Froude 수는0.81~1.12의 범위였다. 흐름저항은 돌출줄눈의 설치간격과 유량에 좌우되었다. ${\lambda}_{nv}$가 9일 때 흐름저항이 가장 큰 것으로 나타났다. 세로돌출줄눈은 유량이 증가하면 d형 조도에서는 흐름저항을 감소시켰으나 k형 조도에서는 흐름저항을 증가시켰다. 흐름저항의 증가폭은 ${\lambda}_{nv}$이 9~12의 범위에서 상대적으로 더 크게 나타났다. 세로돌출줄눈에 의한 흐름저항은 대부분 형상저항에 의한 것이며 그 등가조도높이는 수심규모로 발생할 수 있고 흐름저항에 미치는 영향이 매우 크다. 측벽의 세로돌출줄눈은 흐름저항을 증가시키고 최대유속의 발생위치를 수로의 횡단면 중앙방향으로 이동시키는 수단으로 사용될 수 있을 것이다.

성대 결절 및 후두 폴립의 수술 후 보충 치료로서 Accent Method의 유용성 (The Utility of Accent Method as a Supplementary Treatment after Surgery of Vocal Nodule and Laryngeal Polyp)

  • 박혜성;박영실;최두영;김상윤;유승주;남순열
    • 대한후두음성언어의학회지
    • /
    • 제11권1호
    • /
    • pp.39-45
    • /
    • 2000
  • Background and Objectives : Accent method is one of holistic approaches for behavior readjustment of voice therapy The aim of this study is to evaluate the efficacy of the accent method of voice therapy for the patients who have no improvement after LMS. Materials and Methods : Of the patients who had been undergone LMS during the period from Jan. 1999 to Dec. 1999, medical records of 38 patients who had not been improved were studied retrospectively. 19 patients(treatment group) were applied accent method and the other 19 patients(control group) refused voice therapy. The voice of all the patients of both group were analysed with CSL and Aerophone II programs in pre- and post operative period. The voice of treatment group were analysed with Visi-Pitch II program before the application of accent method and after the completion of accent method. Then, the results were compared using paired t-test. Results : The results of voice analysis were not different statistically between pre- and postoperative examination in both group. After application of accent method in the treatment group, fundamental frequency(F$_{0}$) of male, relative average pertubation, and shimmer were revealed significant differences(p<0.01), and decrease in grade(G) scale and roughness(R) scale were statistically Important in perceptual analysis using GRBAS criteria(p<0.01). But $F_0$ of female, maximal phonation time and S to Z ratio were not revealed significant differences. Conclusions : Accent method of voice therapy may be as a supplement- ary therapy in the patients who were not improved after surgery.

  • PDF

Fin 튜브의 와전류탐상을 위한 최적 탐촉자의 설계 (Design of the Fittest Eddy Current Probe for the Fin Tubes)

  • 김영주;이세경;안봉영;정민화
    • 비파괴검사학회지
    • /
    • 제17권3호
    • /
    • pp.156-161
    • /
    • 1997
  • 열 전달 효율을 증가시키기 위하여 튜브의 내 외면에 울퉁불퉁한 지느러미가 부착된 fin 튜브의 와전류탐상을 위하여 와전류 탐촉자를 설계하고 시험하였다. Fin 튜브는 거친 표면으로 인하여 와전류탐상으로 결함을 찾기 위해서는 많은 주의가 필요하다. 본 연구에서는 규격이 다른 와전류 탐촉자를 제작하고 인공 결함 시험편에 대하여 탐상을 실시하였다. 실험한 와전류탐상 신호에 대하여 FFT를 통하여 주파수 스펙트럼을 구하였고 디지털 필터링의 신호 처리를 하여 신호의 주파수 특성을 고찰하였다. 신호와 주파수 특성을 분석한 결과, 본 연구 대상 시험편에서와 같이 1mm 피치의 fin 튜브의 경우 4mm의 코일 거리를 지닌 탐촉자가 가장 좋은 S/N비를 나타내었다.

  • PDF