• Title/Summary/Keyword: Rotor position detection error

Search Result 13, Processing Time 0.035 seconds

A Simplified Analysis Approach on the Rotor Position Detection Error in Sensorless Interior Permanent Magnet Brushless DC Motor Drives (센서리스 매입형 영구자석 브러시리스 직류전동기 구동장치에서 단순화된 회전자 위치검출 오차 분석 방법)

  • Lee, Kwang-Woon;Park, Tae-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.449-452
    • /
    • 2016
  • This paper presents a simplified analysis on the rotor position detection error in sensorless interior permanent magnet brushless DC motor (BLDCM) drives, wherein terminal voltage sensing based on the back-electromotive force (back-EMF) zero-crossing point detecting circuitry is employed. The effect of a rotor saliency on the back-EMF's zero-crossing point detection is analyzed using the extended EMF-based voltage equation of the interior permanent BLDCM in a stationary reference frame, and thus the overall analysis is considerably simplified compared to the conventional one. Simulation results are provided to verify the effectiveness of the proposed method.

Improvement of Initial Rotor Position Detection for Permanent-Magnet Synchronous Motor Using Magnetic Position Sensor (영구자석형 동기전동기에서 자기식 위치 센서를 사용한 초기 회전자 위치 검출 성능의 개선)

  • Park, Mun-Su;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.398-404
    • /
    • 2021
  • This paper proposes a method of using a magnetic position sensor to detect accurately the rotor position required to perform vector control of a permanent-magnet synchronous motor, particularly the initial rotor position at startup. In the existing vector control systems, the initial rotor position was determined using the output signals of the Hall sensors, or the control was performed in a sensorless method without using such a sensor. On the other hand, the accuracy is degraded due to the occurrence of a position detection error, and the practicality was not satisfactory. This paper attempts to detect the initial rotor position using a magnetic position sensor to solve this problem. This method is used to solve the deteriorating starting characteristics of the motor in the vector control system. In addition, to lower the price of a low-power vector control inverter, this paper proposes a method of integrating the existing sensors and reducing the price to less than half using a magnetic position sensor for speed and position detection.

Rotor Position Estimation of 3-Phase PM BLDC Motor by 2Hall-IC, 1Hall-IC (2Hall-IC, 1Hall-IC를 이용한 PM BLDCM의 회전자 위치검출)

  • Lee, Byoung-Kuk;Kim, Yuen-Chung;Yoon, Yong-Ho;Kim, Hack-Seong;Won, Chung-Yuen;Chun, Jang-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.56-64
    • /
    • 2006
  • Generally, Permanent Magnet Brushless DC Motor(PM BLDC) is necessary the Hall-IC to detect the rotor position. But it will take place the operation standstill of motor or error of rotor position detection according to the circumference temperature, humidity, or limited surroundings. This paper propose the algorithm of rotor position detection only using one or two Hall-IC. Therefore we can estimate information of the others phase in sequence through a rotor instead of using three Hall-IC at 3 phase motor. This paper identify the same characteristics, performance and function of protection circuit by the proposed algorithm with the 3 phase PM BLDC motor in comparison with general method.

A position Detector of Permanent Magnet Step Motors (영구 자석형 스텝모터의 위치 검출)

  • 원종수;정훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.10
    • /
    • pp.703-712
    • /
    • 1987
  • A position detection method for 2 phase bifilar permanent magnet step motors is proposed. The back emfgenerated on 2 phase windings by rotor permanent magnet is calculated using motor terminal voltage and current by analog circuit, and the rotor position output is obtained from tese back emf signals through some logical manipulation circuit. This position detector functionally acts like a 2 channel optical incremental encoder, and it is also shown by experimental results that it works well over wide range of speed or under resonant condition where the rotor rings around the detent position. Its resolution is twice of the number of steps per revolution. Bu software implemented on micro-processor, the reliability of position output is enhanced, detecting and correcting error dut to external and/ or internal noise.

An Analysis of Position Detection Error of the Sensorless Controller for BLDC Motors (영구자석 매입형 BLDC 모터의 Sensorless 속도제어기 위치검출 오차 분석)

  • Lee, Dong-Myung;Kim, Hag-Wone;Yang, Soon-Bae;Ahn, Jun-Ho;Cho, Kwan-Yuhl
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2761-2763
    • /
    • 1999
  • In this paper, we analyzed the characteristics of the detected EMF signals used to detect the rotor position in the IPM(Interior Permanent Magnet) BLDC motor and SPM (Surface Permanent Magnet) BLDC motor. The position sensing signal, in the IPM BLDC motors, advances the real rotor position due to the variation of the rotor inductances. This fact was verified by the simulation and experiment.

  • PDF

BLAC speed contol using precision Velocity Estimation through the Rotor Position ObservationR (관측 위치를 지령치로 하는 새로운 속도추정 알고리즘을 이용한 BLAC 속도제어)

  • Lee, Sang-Hun;Song, Hyin-Jig;Park, Chan-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.93-102
    • /
    • 2014
  • Recently the interest in permanent magnet alternating motor using for electric compressor become great. Especially the research on Interior Permanent Magnet Motor has been doing actively for its advantages in the energy density and the efficiency. In order to control the output of motor to the desired value, the current control or speed control of motor are required. The accurate detection of rotor position and speed information are necessary for the control of motor. In general, the encoder, hall sensor, and resolver are used to obtain the information of motor position and speed and the speed detection algorithm, M/T method, is applied. However, the M/T method causes the error depending on rotor speed. Therefore, this M/T speed detection method is not perfect. In this paper, it is proposed that the PI control with a 1st transfer function and the integration element between velocity and position are composed in series and this feeds back to the reference value of position angle. The proposed algorithm is a function of the integral elements 2nd term, speed element, is used as an output. Thus, it is possible to detect the correct speed by configuring like the mechanical structure similarly. The proposed algorithm is verified by using PSIM DLL and is applied to the BLAC motor drive. And also it is confirmed that this system estimates the accurate speed regardless of rotor speed changes. As a example, the experimental results and simulations shows that the proposed method is very effective.

An Analysis of Position Detection Error of Sensorless Controller and Modeling of Drive System for Interior Permanent Magnet BLDC Motors (영구자석 매입형 BLDC 전동기 센서리스 제어시스템의 위치검지 오차분석 및 모델링)

  • Lee, Dong-Myung;Kim, Hag-Wone;Cho, Kwan-Youl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • This paper proposes the modeling of sensorless drive system using 120 degree conduction method for IPM (Interior Permanent Magnet) BLDC motors and analyzes characteristics of the terminal voltage that is used to detect the rotor position. This paper shows that the ZCP (Zero-Crossing Point) of the measured terminal voltage used In sensorless control is ahead of that of the back EMF of IPM motors because they have a saliency. This research also analyzes that the amount of position detection error is related to saliency, rotor speed, and load condition. In addition, this paper shows that motors have bigger advance angles than we have expected because the ZCP of terminal voltage precedes the actual ZCP, and under operation conditions such as heavy load and high speed it may generate abnormal currents that flow toward opposite direction after phase current becomes zero.

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Parallel Sensorless Speed Control using Flux-axis Current for Dual SPMSMs Fed by a Single Inverter

  • Kim, Chang-Bum;Yun, Chul;Yoon, Byung-Keun;Cho, Nae-Soo;Kwon, Woo-Hyen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1048-1057
    • /
    • 2015
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors (SPMSMs) fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position; consequently, the position sensor is deemed essential for finding the rotor position. The parallel sensorless speed control method proposed in this paper uses no position sensor, instead it compares the flux-axis current from the connection between the back-EMF for torque angle and current in unbalanced load conditions. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Performance Enhancement of Sensorless Drive for Brushless DC Motors using Digital Filter (디지틀 필터를 이용한 브러시리스 직류 전동기용 센서리스 드라이브의 성능 향상에 관한 연구)

  • Yeo, Hyeong-Gi;Kim, Tae-Hyeong;Park, Jeong-Bae;Lee, Gwang-Un;Yu, Ji-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.63-68
    • /
    • 1999
  • This pper describes a digital sensorless drive of permanent magnet brushless DC motors. In order to detect in real time the rotor positions of which Emf becomes zero, terminal voltages are sampled during PWM duty cycle. This method generates detection error in indirect sensed position, which is the harmonic component of PWM frequency. In this paper, the drive adopted Butterworth low pass filter for rejection of the sensing error and for accurate estimation of commutation time. Analytical design process of the digital filter is proposed and the experimental results show that the performance of the proposed sensorless drive is superior to that of the sensorless drives without filterint.

  • PDF