• Title/Summary/Keyword: Rotational motion artifact

Search Result 5, Processing Time 0.018 seconds

Cancellation of MRI Artifact due to Rotational Motion (회전운동에 기인한 MRI 아티팩트의 제거)

  • 김응규
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.4
    • /
    • pp.411-419
    • /
    • 2004
  • When the imaging object rotates in image plane during MRI scan, its rotation causes phase error and non-uniform sampling to MRI signal. The model of the problem including phase error non-uniform sampling of MRI signal showed that the MRI signals corrupted by rotations about an arbitrary center and the origin in image plane are different in their phases. Therefore the following methods are presented to improve the quality of the MR image which includes the artifact. The first, assuming that the angle of 2-D rotational motion is already known and the position of 2-D rotational center is unknown, an algorithm to correct the artifact which is based on the phase correction is presented. The second, in case of 2-D rotational motion with unknown rotational center and unknown rotational angle, an algorithm is presented to correct the MRI artifact. At this case, the energy of an ideal MR image is minimum outside the boundary of the imaging object to estimate unknown motion parameters and the measured energy increases when the imaging object has an rotation. By using this property, an evaluation function is defined to estimate unknown values of rotational angle at each phase encoding step. Finally, the effectiveness of this presented techniques is shown by using a phantom image with simulated motion and a real image with 2-D translational shift and rotation.

Cancellation of MRI Artifact due to Rotational Motion in Image Plane (화상평면내 회전운동에 의한 MRI 아티팩트의 제거)

  • 김응규;이충호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.601-603
    • /
    • 2002
  • MRI 스캔중 촬상 대상물의 화강평면내에서의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. 따라서, 아티팩트가 포함된 MR 화상의 화질열화를 개선하기 위하여 다음과 같은 방법들을 제안한다. 우선, 미리 주어진 회전파라메타써 쌍일처 보간과 중첩 특성을 이용해서 k 공간 불균일 표본화 데이터를 수정하는 알고리즘과, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심 위치가 미지인 경우에 대해 위상보정에 기초한 아티팩트를 보정하는 알고리즘 및 회전중심과 각도가 모두 미지인 2차원 회전운동에 대해 아티팩느를 보정하는 알고리즘을 제안한다. 이 때, 미지운동 파라메타를 예측하기 위해 찰상대상물의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 활상 대상물의 회전이 존재할 때 측정된 에너지가 증가한다는 성질을 이용했다. 이러만 성질을 이용해서 시뮬레이션 화상에 적용한 결과 제안한 방법에 대한 유효성을 확인하였다.

  • PDF

Artifact Cancellation due to Rotational Motion in MRI (MRI내 회전운동에 기인한 아티팩트 제거)

  • Kim, Eung-Kyeu;Lee, Soo-Jong
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.155-158
    • /
    • 2005
  • MRI 스캔시 화상평면내에서 촬상대상물체의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. MRI 신호의 위상오차와 불균일 표본화에 대한 문제의 모델은 화상평면내 임의 중심과 원점에 관한 회전운동에 의해 열화된 MRI 신호들사이에 위상차가 존재함을 나타낸다. 이에 아티팩트가 포함된 MR 화상의 화질을 개선하기위해서 다음과 같은 방법을 제안한다. 우선, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심의 위치가 미지인 경우에 대해 위상보정에 기초한 아티팩트를 보정하는 알고리즘과, 다음으로, 회전중심과 각도가 모두 미지인 2차원 회전운동에 대해 아티팩트를 보정하는 알고리즘을 제안한다. 이때, 미지 운동 파라메타를 예측하기위해 촬상대상물체의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 촬상대상물체의 회전이 존재할 때 측정된 에너지는 증가한다는 성질을 이용한다. 이러한 성질을 이용해서 각 위상부호화 단계에서 미지의 회전각 크기를 추정하기위한 평가함수가 도입된다. 최종적으로 시뮬레이션 화상 및 실제화상에 적용해서 제안한 본 방법의 유효성을 확인한다.

  • PDF

A STUDY ON THE ARMILLARY SPHERE OF TONGCHEON-UI DESCRIBED BY HONG DAE-YONG (홍대용 통천의의 혼천의 연구)

  • MIHN, BYEONG-HEE;YUN, YONG-HYUN;KIM, SANG HYUK;KI, HO CHUL
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.79-95
    • /
    • 2021
  • This study aims to develop a restoration model of an armillary sphere of Tongcheon-ui (Pan-celestial Armillary Sphere) by referring to the records of Damheonseo (Hong Dae-Yong Anthology) and the artifact of an armillary sphere in the Korean Christian Museum of Soongsil University. Between 1760 and 1762, Hong, Dae-Yong (1731-1783) built Tongcheon-ui, with Na, Kyung-Jeok (1690-1762) designing the basic structure and Ann, Cheo-In (1710-1787) completing the assembly. The model in this study is a spherical body with a diameter of 510 mm. Tongcheon-ui operates the armillary sphere by transmitting the rotational power from the lantern clock. The armillary sphere is constructed in the fashion of a two-layer sphere: the outer one is Yukhab-ui that is fixed; and the inner one, Samsin-ui, is rotated around the polar axis. In the equatorial ring possessed by Samsin-ui, an ecliptic ring and a lunar-path ring are successively fixed and are tilted by 23.5° and 28.5° over the equatorial ring, respectively. A solar miniature attached to a 365-toothed inner gear on the ecliptic ring reproduces the annual motion of the Sun. A lunar miniature installed on a 114-toothed inner gear of the lunar-path ring can also replay the moon's orbital motion and phase change. By the set of 'a ratchet gear, a shaft and a spur gear' installed in the solstice-colure double-ring, the inner gears in the ecliptic ring and lunar-path ring can be rotated in the opposite direction to the rotation of Samsin-ui and then the solar and lunar miniatures can simulate their revolution over the period of a year and a month, respectively. In order to indicate the change of the moon phases, 27 pins were arranged in a uniform circle around the lunar-path ring, and the 29-toothed wheel is fixed under the solar miniature. At the center of the armillary sphere, an earth plate representing a world map is fixed horizontally. Tongcheon-ui is the armillary sphere clock developed by Confucian scholars in the late Joseon Dynasty, and the technical level at which astronomical clocks could be produced at the time is of a high standard.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF