• 제목/요약/키워드: Rotation recovery

검색결과 97건 처리시간 0.029초

Correlation Between Electrical Activity of Type I Neuron and c-Fos Expression in the Medial Vestibular Nuclei Following Unilateral Labyrinthectomy in Rats

  • Park, Byung-Rim;Doh, Nam-Yong;Kim, Min-Sun;Chun, Sang-Woo;Lee, Moon-Young;Lee, Sung-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권5호
    • /
    • pp.505-513
    • /
    • 1997
  • To search the correlations between electrical activity and c-Fos expression in the process of vestibular compensation, we examined the changes of those two parameters in the medial vestibular nuclei (MVN) of unilaterally labyrinthectomized (ULX) rats. Spontaneous nystagmus with fast component toward the intact side disappeared gradually within 48 hours. Fourty eight hours after ULX, directional preponderance of the eye movement induced by sinusoidal rotation of the whole body which represents the symmetry of bilateral vestibular functions showed less than 20% by rotation of 0.1, 0.2, and 0.5 Hz, indicating the recovery of symmetry in bilateral vestibular functions. Six hours after ULX, spontaneous electrical activity of type I neurons resulted in asymmetry between bilateral MVN, however, the asymmetry of the electrical activity was decreased 48 hours after ULX. Immunocytochemical staining revealed that ULX produced dramatic induction of c-Fos positive cells in the MVN bilaterally. The number of c-Fos immunoreactive cells in the contralateral MVN was significantly higher than those in the ipsilateral MVN (p<0.0001) 2 hours after ULX. Thereafter, the number of c-Fos positive cells decreased bilaterally and was slightly, but not significantly higher in the ipsilateral MVN at 48 hours after ULX. The present results suggest that both electrical activity of type I neurons and c-Fos expression in MVN following ULX will reflect underlying mechanisms of recovery process of vestibular compensation.

  • PDF

일측 전정기관 손상 흰쥐에서 동측의 내측 전정신경핵 활동성에 대한 전정기관의 전기자극 효과 (Effects of Electrical Stimulation of the Vestibular System on Neuronal Activity of the Ipsilateral Medial Vestibular Nuclei Following Unilateral Labyrinthectomy in Rats)

  • 이문영;김민선;박병림
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권3호
    • /
    • pp.263-273
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of electrical stimulation on vestibular compensation following ULX in rats. Electrical stimulation (ES) with square pulse ($100{\sim}300uA$, 1.0 ms, 100 Hz) was applied to ampullary portion bilaterally for 6 and 24 hours in rats receiving ULX. After ES, animals that showed the recovery of vestibular symptoms by counting and comparing the number of spontaneous nystagmus were selected for recording resting activity of type I, II neurons in the medial vestibular nuclei (MVN) of the lesioned side. And then the dynamic neuronal activities were recorded during sinusoidal rotation at a frequency of 0.1 Hz and 0.2 Hz. The number of spontaneous nystagmus was significantly different 24 hours (p<0.01, n=10), but not 6 hours after ULX+ES. As reported by others, the great reduction of resting activity only in the type I neurons ipsilateral to lesioned side was observed 6, 24 hours after ULX compared to that of intact labyrinthine animal. However, the significant elevation (p<0.01) of type I and reduction (p<0.01) of type II neuronal activity were seen 24 hours after ULX+ES. Interestingly, gain, expressed as maximum neuronal activity(spikes/sec)/maximum rotational velocity(deg/sec), was increased in type I cells and decreased in type II cells 24 hours after ULX+ES in response to sinusoidal rotation at frequencies of both 0.1 Hz and 0.2 Hz. This result suggests that accompanying the behavioral recovery, the electrical stimulation after ULX has beneficial effects on vestibular compensation, especially static symptoms (spontaneous nystagmus), by enhancing resting activity of type I neurons and reducing that of type II neurons.

  • PDF

전정안구반사를 이용한 평형감각 평가용 시뮬레이터의 개발 (Development of Simulator for Evaluation Balance by Using Vestibuloocular Reflex)

  • 임승관;김규겸;정호춘;진달복;김민선;박병림
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1997년도 한국감성과학회 연차학술대회논문집
    • /
    • pp.157-162
    • /
    • 1997
  • The purpose of this study was to develop a sinusoidal rotatory chair systim for evaluating the vestibular function in patients suffered from vertigo with vestibualr disorders. The sinusoidal rotatory chair system is composed of a rotatory chair systim and softwares. Maximum velocity of the rotatiry chair was upto 60 degree per second and frequency range was 0.01 to 0.64 Hz. To evaluate the vestibular function in vertigo patients, vestibuloocular reflex was measured by sinusoidal rotation of the whole body about vertical axis in the darkness, and optokinetic nystagmus, visual vestibuloocular reflex , and visual supression test were also performed. Eye movement was measured by means of a electronystgmograph amplifier through Ag-AgCI surface electrodes. Gain, phase, and symmetry were obtained from analysis of the eye movement ineuced by vestibular or visual stimulation. In healthy adults, sinusoidal rotation of the shole body produced nystagmus, of which gain was directly proportional to the velocity of stimulation. The gain of visual vestibuloocular reflex or optokinetic nystagmus, and it was suppressed markedly by visual suppression test. These results suggest that the sinusoieal rotatory chair systim which was developed by this study can evaluate the vestibular function quantitatively, also this system is very useful to diagnose and to dstimate the vestibualr function during recovery from vertigo

  • PDF

운동과 관절가동술을 혼합한 중재가 어깨관절 내적 충돌증후군을 가진 청소년기 야구선수의 관절가동범위, 통증정도, 기능수행정도에 미치는 효과 (Effects of Joint Mobilization Intervention Combined with Exercise on Range of Motion, Pain Intensity, and Functional Performance in Adolescent Baseball Players with Internal Impingement of the Shoulder)

  • 오태영;추연기;유일영
    • 대한물리의학회지
    • /
    • 제13권2호
    • /
    • pp.11-19
    • /
    • 2018
  • PURPOSE: The aim of this study was to identify the effects of joint mobilization intervention combined with exercise on range of motion (ROM), pain intensity, and functional performance in adolescent baseball players with internal impingement syndrome of the shoulder. METHODS: The subjects were 30 adolescent baseball players diagnosed with internal impingement. Ten subjects were randomly assigned to each of 3 groups: Group 1 (exercise only), Group 2 (joint mobilization combined with exercise), and Group 3 (rest-only control group). Three weekly interventions were given for 4 weeks (the control group rested for 4 weeks). The main outcome measures were goniometer, visual analogue scale (VAS), and Korean Kerlan Jobe shoulder-elbow (K-KJOC) scores. The ROM (external and internal rotation), pain intensity (at the moment of throwing), and functional performance were compared among the groups. RESULTS: No significant difference was observed among the groups in the range of external rotation of the shoulder before and after the intervention, but the range of internal rotation was significantly increased in Group 2 compared to Groups 1 and 3. Pain intensity was significantly lower in Group 2 than in Group 1 and 3, and functional performance was significantly increased in Group 2 compared to Group 1 and 3. CONCLUSION: An intervention that combined joint mobilization with exercise was more effective than resting or exercise alone for rapid recovery from sports injury and improvement in athletic performance.

기계식(機械式) 회전(回轉)레이크를 이용(利用)한 생활계(生活界) 폐기물(廢棄物) 필름류(類) 선별장치(選別裝置) 개발(開發)에 관(關)한 연구(硏究) (Development of Separation System with Rotating Rakes for Recovery of Film-based Plastics)

  • 이병선;나경덕;한상국;최우진;박은규
    • 자원리싸이클링
    • /
    • 제19권3호
    • /
    • pp.24-32
    • /
    • 2010
  • 본 연구에서는 생활폐기물 전처리 시설 및 재활용 선별시설로 반입되는 필름류를 선별하기 위한 기계식 회전레이크를 개발하였으며, 성능평가 및 환경적합성 검토를 통하여 현장 적용 가능성 평가를 수행하였다. 실험결과 처리용량은 벨트컨베이어속도 38.5 m/min, 레이크 회전속도 26.0 rpm(1,2차 레이크 개수는 각각 39개, 52개, 3차 브러쉬 48개)에서 5.3 ton/hr로 설계용량인 5.0 ton/hr를 만족하였으며, 레이크 회전속도 28.0 rpm에서 필름류 회수율은 92.60%, 순도 96.50%로 매우 높게 나타났다. 본 장치에 대한 소음, 진동 및 비산먼지 농도 등에 대한 환경성 평가 결과, 환경오염법적배출허용 기준치를 모두 만족하는 것으로 조사되었다. 또한, 선별된 필름류를 대상으로 고형연료(RPF; Refuse Plastic Fuel) 제조를 통한 재활용 가능성을 평가한 결과, 발열량 약 9,740.3 kg/kcal, 염소함량 약 0.18%로 고형연료 품질기준 1등급을 만족하였다. 따라서 필름류 선별장치를 재활용 선별시설에 적용할 경우 작업량 증가 및 작업환경의 개선이 가능하고, 필름류 제거를 통한 자동화선별장치의 선별효율을 개선 할 수 있을 것으로 사료된다. 또한, 선별된 필름류를 고형연료로 제조하면 화석연료의 대체 에너지원으로서 사용 가능할 것으로 사료된다.

증상 정도, 기간, 불편정도 및 회복력 기반 미병 설문지의 신뢰도 및 구성 타당도 평가 (The Evaluation of Reliability and Validity for Mibyeong Questionnaire)

  • 장은수;윤지현;이영섭
    • 대한한의진단학회지
    • /
    • 제21권1호
    • /
    • pp.13-25
    • /
    • 2017
  • Objectives The purpose of this study was to evaluate the reliability and the validity of Mibyeong Questionnaire (MQ). The subjects enrolled in this study was 165 from July 2015 to Jan. 2016. The surveys were conducted twice with 3 month terms. Methods The Cronbach's ${\alpha}$ analysis for internal reliability, Pearson Correlation Coefficient analysis for test-retest reliability, Factor analysis with varimax rotation for construct validity, Kappa analysis for diagnostic reliability were used. The significant p-value was less than 0.05. Results and Conclusions The result showed that the Cronbach's ${\alpha}$ of MQ was .857-.937 and total was .913. The reliabilities between test and retest for the MQ were .666-.832 (0.416-0.673, in case of including recovery question) in intraclass correlation coefficient (ICC). The Kappa of recovery question in each item was ranged 0.23(80.6% in agreement rate) to .46(87.9% in agreement rate). In test-retest the Kappa value of Mibyeong diagnosis referred by median value was .418(71% in agreement rate). This study revealed that MQ is a reliable and valid questionnaire.

FUNDAMENTAL STUDY ON THE RECOVERY AND REMOVAL OF WHITE PHOSPHORUS FROM PHOSPHORUS SLUDGE

  • Jung, Joon-Oh
    • Environmental Engineering Research
    • /
    • 제10권1호
    • /
    • pp.38-44
    • /
    • 2005
  • Electro-thermal production of white phosphorus(WP, P4) generates substantial amount of highly toxic phossy water and sludges. Because of their high phosphorus contents and lack of reliable processing technology, large tonnages of these hazardous wastes have accumulated from current and past operations in the United States. In this study, two different methods for treatment of phosphorus sludge were investigated. These were bulk removal of WP by physical separation(froth flotation) and transformation of WP to oxyphosphorus compounds by air oxidation in the sludge medium. Kerosene, among other collectors, resulted in selective flotation of WP from the associated mineral gangue. Solvent action of kerosene occurring on the WP surface(by rendering WP particles hydrophobic) might produce the high selectivity of WP. The WP recovery in the froth was 79.3% from a sludge assaying 34.2% of WP. In the oxidation study, air gas was dispersed in the sludge medium by the rapid rotation of the impeller blades. The high level of sludge agitation intensity caused a fast completion of the oxidation reactions and it resulted in the high percentage conversion of WP to PO4-3 with PO3-3 making up almost all portion of oxyphosphorus compounds. The WP analysis on the treated sludge showed that supernatant solution and solid residue contained an average of 4.2 μg/L and 143 ppm respectively from the sludge containing about 26 g of WP. Further investigation will be required on operational factors to better understand the processes and achieve an optimum condition.

경추 전방 유합 환자의 장기 수술 결과에 영향을 주는 방사선학적 요인 분석 (Analysis of Radiologic Factors Affecting Longterm Surgical Results of Anterior Cervical Fusion Patients)

  • 최일승;서대희;박성춘;채의병;최선욱;송관영;강동수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.194-200
    • /
    • 2001
  • Object : Anterior cervical discectomy and fusion is accepted as appropriate surgical intervention for disease processes of the ventral cervical spine. In some cases, however, improvement of symptom following operation develop myelopathy or rhizopathy at longterm follow-up. We studied to clarify the correlation between clinical results and plain radiologic findings at long term follow-up. Methods : A total of 86 patients who underwent anterior cervical discectomy and fusion were grouped into deteriorated and good recovery group. These two groups were compared in lateral functional roentgenograms on the cervical kyphosis and disc height at fused level, sagittal plane rotation and dynamic sagittal canal diameter at adjacent level. Results : The presence of cervical kyphosis and disc height at fused level do not correlate with long term followup results. Sagittal plane rotation of more than 20 degrees were identified in 36% of the cases in deteriorated group, whereas the same findings were identified in 15% of the cases in good group. Sagittal diameter of less than 12mm were identified in 48% of the cases in deteriorated group, whereas the same finding were identified in 8% of the cases in good group. Preoperatively, sagittal plane rotation of more than 20 degrees at adjacent level were identified in 28% of the cases in deteriorated group, whereas the same findings were identified in 13% of the cases in good group. Preoperatively sagittal diameter of less than 12mm at adjacent level were identified in 40% of the cases in deteriorated group, whereas the same finding were identified in 7% of the cases in good group. Conclusion : Large sagittal plane rotation and small dynamic sagittal diameter at adjacent level were factors that might be associated with later clinical deterioration after cervical anterior fusion.

  • PDF

Effects of steroid injection during rehabilitation after arthroscopic rotator cuff repair

  • Ha, Joong-Won;Kim, Hyunkyo;Kim, Seong Hun
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.166-171
    • /
    • 2021
  • Background: This study aims to compare the clinical outcomes of steroid injections during the rehabilitation period after arthroscopic rotator cuff repair (ACRC). Methods: Among patients who underwent ARCR, 117 patients who met the inclusion and exclusion criteria were enrolled. Pain and range of motion (ROM) recovery at the 3-, 6-, and 24-month follow-up visits and functional outcome at the 24-month follow-up were compared between 45 patients who received ultrasound-guided subacromial steroid injection at postoperative week 4 or 6 and 72 patients who did not. Functional outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) score and Constant score. Healing of the repaired tendon and retear were observed at the 6-month follow-up via magnetic resonance imaging (MRI) or computed tomography (CT) arthrography. Results: At the 3-month follow-up, the steroid injection group showed lower visual analog scale scores than the control group (p<0.05) and showed faster recovery of forward flexion and internal rotation (p<0.05). From the 6-month follow-up, the two groups did not show differences in pain and ROM, and the ASES score and Constant score also did not significantly differ at the 24-month follow-up. The two groups did not differ in retear rate as determined by MRI or CT arthrography at the 6-month follow-up. Conclusions: This study demonstrated that ultrasound-guided subacromial steroid injection at 4 or 6 weeks after ARCR leads to quick pain reduction and ROM recovery until 3 months after surgery. Therefore, subacromial steroid injection is speculated to be an effective and relatively safe method to assist rehabilitation.

Generating 3-D Models of Human Motions by Motion Capture

  • Yamaguchi, I.;Tou, K.;Tan, J.K.;Ishikawa, S.;Naito, T.;Yokota, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1629-1632
    • /
    • 2003
  • A technique is presented for generating a compound human motion from its primitive motions obtained by a motion capture system. Some human fundamental motions are modeled in a 3-D way and registered as primitive motions. Because the factorization method is used for the motion capture, calibration of video cameras and connection of the motion in the direction of time is both unnecessary. Employing these motions, various compound human motions are generated by connecting the motions after having applied rotation and parallel transformation to them. Linear interpolation is done at the discontinuous boundary between primitive motions and smooth connection is achieved. Experimental results show satisfactory performance of the proposed technique. The technique may contribute to producing various complicated human motions without much effort using a strict motion capture system.

  • PDF