• Title/Summary/Keyword: Rotation error

Search Result 461, Processing Time 0.03 seconds

Elimination of Residual Phase Rotation Errors in SC-FDE Received Signals (SC-FDE 수신 신호의 잔여 위상회전에러 제거)

  • Kim, Ji-Heon;Kim, Whan-Woo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.101-102
    • /
    • 2006
  • Similar to Orthogonal Frequency Division Multiplexing (OFDM), a Single Carrier with Frequency Domain Equalization (SC-FDE) system is computationally efficient since equalization is performed on a block of data in the frequency domain. In coherent QAM schemes, the mean phase rotation error caused by the residual carrier frequency offset may lead to serious degradation. When the frequency equalizer is combined with the mean phase error tracking algorithm, its performance can be enhanced noticeably.

  • PDF

Comparisons Among Functional Methods of Axis of Rotation Suitable for Describing Human Joint Motion (인체 관절운동 기술에 적합한 회전축 추정방법의 비교)

  • Kim, Jin-Uk
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.449-458
    • /
    • 2011
  • There are many functional methods for estimating the mean axis of rotation of a joint. However, it is still a controversial issue which method is superior. The purpose of this study was to compare functional methods for estimated axes of rotation from synthetic data. The comparison was made in terms of suitabilities on describing humans in sports. For a more practical situation, the axis error as well as measurement and marker movement error were applied to generated data. Simulations having 1000 times of 80 rotational displacements were performed. The functional methods used in the study were two transformation methods, two fitting methods, and one more transformation method called M. The M method is a combination of S$\ddot{o}$derk & Wedin(1993) and Mardia & Jupp(2000). Another factor of the study was angular velocity with levels of .01, .025, .05, .5 and 1 rad/s. The method M resulted in unbiased, stable, and consistent axis of rotation vectors in all levels of angular velocity except .01 rad/s. Therefore, the method M had the highest validity and reliability of all the methods. The fitting methods were very sensitive in small angular velocities and stable only in the velocities of more than .5 rad/s. The most suitable method for analyzing human motion by using marker photogrammetry is M.

A Novel Rotor Position Error Calculation Method using a Rotation Matrix for a Switching Frequency Signal Injected Sensorless Control in IPMSM (스위칭 주파수 신호 주입 IPMSM 센서리스 제어를 위한 회전 행렬 기반의 새로운 위치 오차 추정 기법)

  • Kim, Sang-Il;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.402-409
    • /
    • 2015
  • This paper proposes a novel rotor position error calculation method for high-frequency signal-injected sensorless control. The rotor position error using the conventional modulation method can be only measured up to ${\pm}45^{\circ}$. In addition, when the rotor position estimation error is not sufficiently small, the small angle approximation in no longer valid. To overcome these problems, this study introduces a new rotor position error calculation method using the rotating matrix. In this study, the position error measurement range of the proposed method is extended from ${\pm}45^{\circ}$ to ${\pm}90^{\circ}$. The linearity between the real rotor position error and the estimated error is maintained by nearly $90^{\circ}$. These features of the proposed method improve the performance of the sensorless control. The validity of the proposed method is verified by simulations and experiments.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

An Error Motion Analysis of Rotary Stage Driven By PZT (PZT로 구동되는 회전 스테이지의 오차 운동 분석)

  • Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Han, Chang-Soo;Lee, Sang-Moo;Nam, Kyung-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.132-136
    • /
    • 2008
  • Axis of rotation error on rotary system are significant; such as the spindle radial error motion of a aligner, wire bonder and inspector machine which results in the poor state of manufactured goods. In this paper, the simple stage which consists of one PZT actuator and rotary encoder, is analyzed and measured by high resolution capacitance type displacement sensor. As the result of experiment, the paper discusses several issues that must be considered when designing rotary stage driven by PZT.

Extended Kalman Filter Based GF-INS Angular Velocity Estimation Algorithm

  • Kim, Heyone;Lee, Junhak;Oh, Sang Heon;Hwang, Dong-Hwan;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.3
    • /
    • pp.107-117
    • /
    • 2019
  • When a vehicle moves with a high rotation rate, it is not easy to measure the angular velocity using an off-the-shelf gyroscope. If the angular velocity is estimated using the extended Kalman filter in the gyro-free inertial navigation system, the effect of the accelerometer error and initial angular velocity error can be reduced. In this paper, in order to improve the navigation performance of the gyro-free inertial navigation system, an angular velocity estimation method is proposed based on an extended Kalman filter with an accelerometer random bias error model. In order to show the validity of the proposed estimation method, angular velocities and navigation outputs of a vehicle with 3 rev/s rotation rate are estimated. The results are compared with estimates by other methods such as the integration and an extended Kalman filter without an accelerometer random bias error model. The proposed method gives better estimation results than other methods.

Three-Way Balanced Multi-level Semi Rotation Sampling Designs

  • Park, You-Sung;Choi, Jai-Won;Kim, Kee-Whan
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.05a
    • /
    • pp.19-24
    • /
    • 2002
  • The two-way balanced one-level rotation design has been discussed (Park, Kim and Choi, 2001), where the two-way balancing is done on interview time in monthly sample and rotation group. We extend it to three-way balanced multi-level design under the most general rotation system. The three-way balancing is accomplished on interview time not only in monthly sample and rotation group but also in recall time. We present the necessary condition and rotation algorithm which guarantee the three-way balancing. We propose multi-level composite estimators (MCE) from this design and derive their variances and mean squared errors (MSE), assuming the correlation from the measurements of the same sample unit and three types of biases in monthly sample.

  • PDF

Rotation Invariant Tracking-Learning-Detection System (회전에 강인한 실시간 TLD 추적 시스템)

  • Choi, Wonju;Sohn, Kwanghoon
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.5
    • /
    • pp.865-873
    • /
    • 2016
  • In recent years, Tracking-Learning-Detection(TLD) system has been widely used as a detection and tracking algorithm for vision sensors. While conventional algorithms are vulnerable to occlusion, and changes in illumination and appearances, TLD system is capable of robust tracking by conducting tracking, detection, and learning in real time. However, the detection and tracking algorithms of TLD system utilize rotation-variant features, and the margin of tracking error becomes greater when an object makes a full out-of-plane rotation. Thus, we propose a rotation-invariant TLD system(RI-TLD). we propose a simplified average orientation histogram and rotation matrix for a rotation inference algorithm. Experimental results with various tracking tests demonstrate the robustness and efficiency of the proposed system.

A Feasible Approach for the Unified PID Position Controller Including Zero-Phase Error Tracking Performance for Direct Drive Rotation Motor

  • Kim, Joohn-Sheok
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.74-84
    • /
    • 2009
  • The design and implementation of a high performance PID (Proportional Integral & Differential) style controller with zero-phase error tracking property is considered in this article. Unlike a ball screw driven system, the controller in a direct drive system should provide a high level of tracking performance while avoiding the problems due to the absence of the gear system. The stiff mechanical element in a direct drive system allows high precise positioning capability, but relatively high tracking ability with minimal position error is required. In this work, a feasible position controller named 'Unified PID controller' is presented. It will be shown that the function of the closed position loop can be designed into unity gain system in continuous time domain to provide minimal position error. The focus of this work is in two areas. First, easy gain tunable PID position controller without speed control loop is designed in order to construct feasible high performance drive system. Second, a simple but powerful zero phase error tracking strategy using the pre-designed function of the main control loop is presented for minimal tracking error in all operating conditions. Experimental results with a s-curve based position pattern commonly used in industrial field demonstrate the feasibility and effective performance of the approach.

A Study on the Analysis of 5-DOF Axis of Rotation Error in Low Speed Rotary Stage (저속 회전 스테이지의 5자유도 회전축 오차 분석에 관한 연구)

  • Han, Chang-Soo;Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Lee, Yung-Gi;Lee, Sang-Moo;Nam, Gyung-Tai
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.23-27
    • /
    • 2007
  • Rotary stages in semiconductor, display industry and many other fields require challenging accuracy to perform their functions properly. Especially, Axis of rotation error on rotary system is significant; such as the spindle error motion of the aligner, wire bonder and inspector machine which result in the poor quality products. To evaluate and improve the performance of such precision rotary stage, undesired movements on the other 5 degrees of freedom of the rotary stage must be measured and analyzed. In this paper, we have measured the three translations and two tilt motions of the worm gear type spindle with high precision capacitive sensors. To obtain the radial error motion, we have used Donaldson's reversal technique. And the axial components of the spindle tilt error motion can be obtained accurately from the axial direction outputs of sensors by Estler face motion reversal technique. Further more we have designed and developed the sensor mounting jig with standard cylinder for reversal method.

  • PDF