• Title/Summary/Keyword: Rotation Scan

Search Result 71, Processing Time 0.055 seconds

A Study on the Head and Neck Posture Related to Cervical Curvature in Patients with Craniomandibular Disorders (경추만곡도를 이용한 두개하악장애에 환자의 두경부자세에 관한 연구)

  • Min-Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.361-376
    • /
    • 1995
  • The purpose of this study was to investigate the relationship between the head and neck postre and the cervical curvature, especially in forward head postrue(FHP). Sixty patients with craniomandibular disorders and thirty dental students without any signs and symptoms of craniomandibular disordres participated in this study as patient groups and sa control group, respectively. The author evaluated the head and neck posture of all subjects by plumb line and CROM( Cervical Ragne of Motion), and had taken cephaograph in natural head position. On the cephalograph the angle of cervical inclination formed by true horizntal plane and 4th cervical vertebra(C4) and the radius of cervical curvature from C1 to C5 were measured. A specially designed ruler was used for measuring cervical curvature. Occlusal contac number and force with T-scan system, electromygraphic activity of cervical muscles with Bio-EMG, and distance of freeway space with Bio-ECN were recorded, respectively. The collected data were processed by SAS/STAT progrm. The obtained results were as follows : 1. In subjects with longer radius which was less cervical curvature, head positioned more anteriorly than subjects with smaller radius, and they showed slightly straight cervical vertebra. 2. Between the patients and the control group, there were no differences in cervical curvature, in forward head position by plumb line and in CROM. But the patient group had a greater cervical inclination than the control group had. 3. There were positive correlation between cervical curvature and forward head position by plumbline,between forward head position y plumb line and that by CROM in patient group. The cervical inclination, however, had negative correlation with cervical curvature, and with forward head postion by plumb line, respectively. 4. In case of showing more cervical curvature and more forward head position by plumb line the head position was defined as forward head posture. In patient group, subjects without forward head posture showed greater posterior teeth contact force than subjects with forward head posture, but in control group, there were no difference between the two subjects. 5. There were higher electromyographic activity in almost all muscles and smaller freeway space in induced forward head posture than those in natural head position in subjects without forward head posture. In conclusion, head position of patients with craniomandibular disorders were not more anterior than that of normal control person, but they had tendency to head extension. From the result of this study, forward head posture could be defined as posterior rotation of upper cervical segment with a straight lower cercial segment due to loss of normal lordosis.

  • PDF

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

Rotation Errors of Breast Cancer on 3D-CRT in TomoDirect (토모다이렉트 3D-CRT을 이용한 유방암 환자의 회전 오차)

  • Jung, Jae Hong;Cho, Kwang Hwan;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Choi, Jin Ho;Jung, Joo-Yong;Choe, Bo Young;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • The purpose of this study was to analyze the rotational errors of roll, pitch, and yaw in the whole breast cancer treated by the three-dimensional radiation therapy (3D-CRT) using TomoDirect (TD). Twenty-patient previously treated with TD 3D-CRT was selected. We performed a retrospective clinical analysis based on 80 images of megavoltage computed tomography (MVCT) including the systematic and random variation with patient setup errors and treatment setup margin (mm). In addition, a rotational error (degree) for each patient was analyzed using the automatic image registration. The treatment margin of X, Y, and Z directions were 4.2 mm, 6.2 mm, and 6.4 mm, respectively. The mean value of the rotational error for roll, pitch, and yaw were $0.3^{\circ}$, $0.5^{\circ}$, $0.1^{\circ}$, and all of systematic and random error was within $1.0^{\circ}$. The errors of patient positioning with the Y and Z directions have generally been mainly higher than the X direction. The percentage in treatment fractions in less than $2^{\circ}$ at roll, pitch, and yaw are 95.1%, 98.8%, and 97.5%, respectively. However, the edge of upper and lower (i.e., bottom) based on the center of therapy region (point) will quite a possibility that it is expected to twist even longer as the length of treatment region. The patient-specific characters should be considered for the accuracy and reproducibility of treatment and it is necessary to confirm periodically the rotational errors, including patient repositioning and repeating MVCT scan.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.