• Title/Summary/Keyword: Rotation Operation

Search Result 388, Processing Time 0.028 seconds

Study on a Noval Simulation Method of Wind Power Generation System Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전시스템의 새로운 시뮬레이션 방법에 관한 연구)

  • 한상근;박민원;유인근
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.6
    • /
    • pp.307-315
    • /
    • 2003
  • This paper proposes a novel simulation method of WPGS (Wind Power Generation System). The rotation speed control method of turbine under variable wind speed using the pitch control is proposed. Moreover, when wind speed exceeds the cut-out wind speed, the turbine will be stopped by controlling pitch angle to 90$^{\circ}$, otherwise it will be controlled to steady-state operation. For the purpose of effective simulation, the SWRW (Simulation method for WPGS using Real Weather condition) is used for the utility interactive WPGS simulation in this paper, in which those of three topics for the WPGS simulation: user-friendly method, applicability to grid-connection and the utilization of the real weather conditions, are satisfied. It is impossible to consider the real weather conditions in the WPGS simulation using the EMTP type of simulators and PSPICE, etc. External parameter of the real weather conditions is necessary to ensure the simulation accuracy. The simulation of the WPGS using the real weather conditions including components modeling of wind turbine system is achieved by introducing the interface method of a non-linear external parameter and FORTRAN using PSCAD/EMTDC in this paper. The simulation of long-term, short-term, over cut-out and under cut-out wind speeds will be peformed by the proposed simulation method effectively. The efficiency of wind power generator, power converter and flow of energy are analyzed by wind speed of the long-term simulation. The generator output and current supplied into utility can be obtained by the short-term simulation. Finally, transient-state of the WPGS can be analyzed by the simulation results of over cut-out and under cut-out wind speeds, respectively.

Analysis of Zig-Zag Error in Gantry Type Machine (문형 공작기계의 Zig-Zag 오차 분석)

  • Lee, Eung Suk;Lee, Seung Bum;Kim, Gi Hwan;Min, Deul Le;Park, Jong Bum;Park, Min Su;Jin, E Lim;Kim, Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.157-162
    • /
    • 2015
  • A large five-axis gantry-type machine performs cutting operations by moving the gantry, along with a bed. During operation, there are three sources of position (zig-zag) errors: 1) the position difference between two control motors on the X axis, 2) friction difference from the different column weights, and 3) torque of the rotating spindle. This study improved the performance of a gantry-type machine by analyzing these three error sources. We changed the mass of a column in the gantry structure and measured the effect on the friction result. We also studied the spindle torque influences on the movement performance of the gantry in relation to the spindle rotation.

Development of Bench Tester for Designing the Passive Anti-Rolling Tanks (수동형 감요수조 설계를 위한 벤치테스터 개발)

  • Lew, Jae-Moon;Kim, Hyochul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.452-459
    • /
    • 2015
  • It is important to use bench test results in the design process of anti-rolling tanks. Traditional bench tester is usually designed to perform only roll motions about a fixed axis and relatively small so that the viscous effects may not be neglected. Novel bench tester which could adjust the motion center to realize the coupled motion of sway and roll has been devised and manufactured therefore, large scaled bench tester could be utilized for designing the passive anti-rolling tanks. The time history of the reference signal from the rotation sensor of the bench tester have been recorded and processed to determine the phase angle to derive the Response Amplitude Operator(RAO) of the stabilized ship. The breadth of ART tank model should be large up to 2 m to diminish viscous scale effect and the vertical position of the tank can be varied with the ship's center of motion. The periods and the amplitude of roll motion can be varied from 1.5 sec to 5 sec and up to ±20°, respectively. The components of the tester was expressed in three dimensional digital mockup (DMU) and assembled together in the CAD space. The final configuration of the bench tester has been determined by confirming the smooth operation of the moving parts without interference through the animation in CAD space. New analytic logic are introduced for the determination of hydrodynamic moment and phase difference due to fluid motion in ART and verified through the test. The developed bench tester is believed to be effective and accurate for the verification of stabilization effect of ART taking into the consideration of the sway effect in the design stage.

Do Knots Matter in Superior Labrum Anterior to Posterior Lesions Repair?

  • Jeong, Hyeon Jang;Joung, Ho Yun;Kim, Dae Ha;Rhee, Sung Min;Yang, Seok Hoon;Kim, Woo;Oh, Joo Han
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.68-76
    • /
    • 2017
  • Background: In general, the outcomes of arthroscopic repair for superior labrum anterior to posterior lesions (SLAP) are favorable, however, persistent pain and limitation of motion are not rare complications. One of the possible cause is a "knot-ache". This study evaluated the results of reoperation of symptomatic recurrent SLAP lesions and asked whether the knot is associated with postoperative complications. Methods: Between 2005 and 2015, a total of 11 patients who had undergone arthroscopic SLAP repair were reoperated for recurrent symptomatic SLAP lesion. By retrospective chart review, operative findings, the visual analogue scale for pain (pVAS), the range of motion (ROM), and functional scores were analyzed. Results: The mean age of the study participants was 38.3 years, and the mean follow-up period was 42.5 months. In the primary operation, there were nine cases of repairs with conventional knot-tying anchors and three cases with knotless anchors. Impingement of the knots during abduction and external rotation of the shoulder was observed in the all cases with knot-tying anchors. The mean pVAS, ROM, and functional scores significantly improved with reoperation. At the final follow-up, the mean satisfaction VAS was 8.3. Conclusions: The knots of suture anchor maybe a possible etiology of the pain, which we termed a "knot-ache". Considering that reoperation is performed due to pain after primary repair, the use of knotless suture anchor may have benefits of eliminating one of possible cause, "knot-ache". Therefore, authors suggest the use of knotless anchors during reoperation for recurrent or recalcitrant pain after primary SLAP repair.

Reduction Chattering Error of Reed Switch Sensor for Remote Measurement of Water Meter (Reed Switch 센서를 이용한 원격 검침용 상수도 계량기에서 Chattering 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kwon, Jong-Won;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.377-379
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors used for automatic remote measurement of water supply system, a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used in measurement application by detecting the rotational or translational displacement. To apply for flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just installed simply on the mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor, two steel leaf springs make mechanical contact and apart as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But it occurs data difference or errors by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing car near to the switch sensor installed location. In order to reduce chattering error, most system uses just software methods for example using filter and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical hysteresis characteristics.

  • PDF

Electromagnetic Interference Suppression Method of Motor Assembly for Aircraft Application (항공용 모터 조립체의 전자기 간섭 감쇠 방안)

  • Kim, Jee-Heung;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.351-358
    • /
    • 2018
  • In this study, we propose a method of suppressing the leakage noise signal of motor assembly through the test. The motor assembly is mounted on outside of the aircraft to rotate an antenna and must satisfy RE102 requirement on MIL-STD-461F in terms of electromagnetic interference. It is confirmed by RE102 test result hat the leakage noise signal of the equipment occurs due to external influx through the power and control cable and rotation of the motor. And it is ascertained that the part where internal/external physical shielding is difficult to rotate is the leakage path. To reduce the leakage noise signal, the electrical ground reinforcement and the electric shielding structure considering the operation of the equipment is applied and it is verified that the requirement is satisfied. Finally, we verified that required specification are met by applying circular corrugated choke with interlocking shapes and conductive grease to the noise leakage path.

Study on Optimal Design and Analysis of Worm Gear and Casing of 5 Ton Class Worm Gear Reducer (5톤급 웜기어 감속기의 워엄기어와 케이싱의 최적설계 및 해석에 관한 연구)

  • Cho, Seong Hyun;Jeon, Chang Min;Qin, Zheon;Kim, Dongseon;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.15-21
    • /
    • 2019
  • The worm reducer is capable of quadrature power transmission when the shafts are disposed at right angles to each other. Since a large reduction ratio can be obtained of up to approximately 1/100 and a sliding movement is performed during operation compared with other gears, the noise and vibration are small, and there is the advantage that reverse rotation can be prevented. On the other hand, severe wear and damage are displayed on the gear and worm tooth surface, and many defects, such as intense heat generation of the reducer, occur. In the reducer case, the four-piece casing method was selected to solve the problems of heat generation, transmission efficiency, and assemblability. In this paper, we analyzed the problems of the worm and worm wheel (the core parts of a 5-Ton worm reducer) and casing through these methods and researched how to solve them.

Treatment of Painful Rotator Interval Widening After Subcoracoid Decompression in Elite Archer - Case Report - (양궁 선수의 오구 충돌 증후군의 치료 후 발생한 회전근 간격의 손상에 대한 치료 - 증례 보고 -)

  • Park, Jin-Young;Lee, Seung-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.280-285
    • /
    • 2010
  • Purpose: Coracoid impingement syndrome refers to subscapularis impingement between the coracoid process and lesser tuberosity of the humerus, and pain may occur when the arm is positioned in forward flexion, internal rotation and adduction. This position is common for archers. Material and methods: A female archer with coracoid impingement syndrome that was uncontrolled by conservative therapy underwent arthroscopic subcoracoid decompression. At the 20th postoperative month of follow up, she complained of painful rotator interval widening and so she underwent arthroscopic rotator interval plication. Results: At the postoperative 6th month of follow up after the second operation, she showed no pain and good functional results, and she returned to competing as an archer. Conclusion: We have reported here on a case of successful treatment of painful rotator widening after subcoracoid decompression in an elite archer.

Performance Improvement of Cylindrical Turbine Guide Bearings with Pad Leading-Edge Tapers for Vertical Hydro-Power Application: Effects of Taper Angle and Length (패드 선단 테이퍼를 갖는 수력 수직 원통형 터빈 가이드 베어링의 성능향상 - 테이퍼 각도와 길이의 영향)

  • Lee, An Sung;Jang, Sun-Yong;Park, Soo Man
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Cylindrical turbine guide bearings (TGBs) with simple plain pads have conventionally been used in vertical hydro-power turbine-generator applications in order to provide turbine runner shafts with smooth rotation guides and supports. To overcome low-load/low-eccentricity performance drawbacks, such as very low film stiffness and lack of design credibility in the stiffness values themselves, of conventional cylindrical TGBs, the introduction of a rotational-directional leading-edge taper to each partitioned pad, simply pad leading-edge taper, has been found to be very effective in enhancing their design-application availability and usefulness. In this study, we investigate the effects of taper angle and length for given taper heights in detail in order to systematically establish the effectiveness of design on the performance improvement of vertical hydro-power application cylindrical TGBs with pad leading-edge tapers. The analysis results with $4-Pad{\times}1-Row$ cylindrical TGBs show that the lubrication performance of the cylindrical TGBs is optimized with an approximate taper angle ratio of 0.8 and taper length ratio of 0.9. We conclude that the introduction of pad leading-edge tapers along with the optimization of taper designs can be very effective in improving the overall operation reliability of cylindrical TGBs and the rotordynamic characteristics of vertical hydro-power turbine-generator rotor-bearing systems as well, to which the TGBs are applied.

Non-contact Vibration Suppression of a Rotating Flexible Disk (회전 유연 디스크의 비 접촉 진동 억제)

  • Um, Yo-Han;Lee, Ho-Ryul;Lee, Sung-Ho;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.169-174
    • /
    • 2005
  • Current information storage devices read/write data on the rotating disk. The axial vibration of a rotating disk should be suppressed for the successful operation of the device. Information storage devices widely used in these days adopt relatively thick disk which is stiff enough to suppress axial vibration under allowable limit. However, the thickness of the disk is going to be thinner and thinner as the small form factor of the devices is getting preferred by the consumer. In this study, a stabilizer system, which is composed with 8 air bearings, is proposed for suppressing the axial vibration of a $95{\mu}m$ thick PC disk in a non-contacting manner. The performance of the stabilizer system is simulated by numerical computation and then confirmed its results through a series of experiment. A thin and flexible disk has various vibration modes when it rotates in high speed. The stabilizer system generates positive as well as negative pressure due to the rotation of flexible disk so that the force due to the pressure distribution pushes and pulls rotating disk in a non-contacting manner. The balance between positive and negative pressure forces can be obtained by adjusting the area and the slope of the air bearing surface. The axial vibration of the flexible disk of 120mm diameter is suppressed successfully from over $1000{\mu}m$ to $30{\mu}m$ peak-to-peak value at the rotational speed of 5,000rpm.

  • PDF