• Title/Summary/Keyword: Rotation Axis

Search Result 628, Processing Time 0.035 seconds

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF

A study on Yang Shi Tai Chi Chuan in Bartenieff Fundamentals Perspectives (바티니에프 기본원리를 통해 본 양식 태극권에 관한 연구)

  • Wang, Zhiquan
    • Trans-
    • /
    • v.8
    • /
    • pp.95-127
    • /
    • 2020
  • This research is based on using Bartenieff Fundamentals to analyze the fundamentals of Tai Chi Chuan's movements in order to develop the methods of relaxation from Tai Chi Chuan's principle movement movements It also shows that the two techniques have commonalities in many ways. First of all, taking a philosophical approach on the body movements of Tai Chi Chuan and Bartenieff, for both methods the ultimate goal is the integration of mind and body. In other words, there is a thread of connection between the East's body and mind monism and the west's Body Awareness. Secondly, looking at it from a Breath Support standpoint as used in the Bartenieff method, the two methods both use the breathing to naturally move the body and relax the body. In Tai Chi Chuan the Breath is the basis of life and the strength of the Body. So the breathing of Tai Chi chuan is what makes body and mind communicate, harmonize and integrate. In other words, Breathing in Tai Chi is realized through mental fusion and affects the movements. This is the same as the Breath Support of Bartenieff. It is said that in every aspect the Breath Support of Bartenieff influences the movement and changes both the inner and outer form of the body. Thirdly, looking at the Core Support used in the Bartenieff method, both methods emphasize core. At the same time of moving and being conscious of one's core, the usage of muscles can be deeper rather than superficial and this enables strong and flexible movement. In Tai Chi Chuan abdominal muscles used when one coughs are consciously engaged through abdominal breathing and so strength is collected in the core. When one exercises like that the core becomes more stable and breathing becomes more smooth. Fourthly, analyzing the Rotary Factor used in the Bartenieff Fundamentals, they both use rotary movement to reach the goal of physical relaxation. The rotation factor of Bartenieff allows movement to be easier and more free because of the characteristic of joint exercise where the center axis moved in three dimensions, this is the same in Tai Chi chuan. According to Tai Chi chuan's circle and Spiral Movements, it can achieve the relaxation through switching into a seamless flow and access space as much as possible. Finally, when looking at Developmental Patterning through Bonnie Bainbridge Cohen's Body-Mind Centering Work theory, presented from Bartenieff developmental model are similar with the developmental process of Tai Chi chuan Breath, Core-Distal Connectivity/Navel Radiation, Head-Tail Connectivity/Spinal Movement, Upper-Lower Connectivity/Homologous, Body-Half Connectivity/Homo-Lateral Connectivity, Cross-Lateral Connectivity/Contra-Lateral Connectivity. They are all similar. In other words, in Tai Chi Chuan energy is gathered in the core through breathing, upper and lower body are connected through the spine, not only homo-laterally but also cross-laterally. Through this study the expression of the dance movements can be more natural. Additionally based on the Body Awareness balance usage of the central axis, joints and body can develop the relax technique.

  • PDF

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance (선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성)

  • Lee, Jeong-Woo;Hong, Se-Mie;Park, Byung-Moon;Kang, Min-Young;Kim, You-Hyun;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.183-188
    • /
    • 2008
  • Aim of this study is to investigate the feasibility of 2D ion chamber array as a substitute of the water phantom system in a periodic Linac QA. For the feasibility study, a commercial ion chamber matrix was used as a substitute of the water phantom in the measurement for a routine QA beam properties. The device used in this study was the I'm RT MatriXX (Wellhofer Dosimetrie, Germany). The MatriXX consists of a 1,020 vented ion chamber array, arranged in $24{\times}24\;cm^2$ matrix. Each ion chamber has a volume of $0.08\;cm^3$, spacing of 0.762 cm. We investigated dosimetric parameters such as dose symmetry, energy ($TPR_{20,10}$), and absolute dose for comparing with the water phantom data with a Farmer-type ionization chamber (FC65G, Wellhofer Dosimetrie, Germany). For the MatriXX measurements, we used the white polystyrene phantom (${\rho}:\;1.18\;g/cm^3$) and also considered the intrinsic layer (${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm) of MatriXX to be equivalent to water depth. In the preliminary study of geometrical QA using MatriXX, the rotation axis of collimator and half beam junction test were included and compared with film measurements. Regarding the dosimetrical QA, the MatriXX has shown good agreements within ${\pm}1%$ compared to the water phantom measurements. In the geometrical test, the data from MatriXX were comparable with those from the films. In conclusion, the MatriXX is a good substitute for water phantom system and film measurements. In addition, the results indicate that the MatriXX as a cost-effective novel QA tool to reduce time and personnel power.

  • PDF

Rietveld Structure Refinement of Biotite Using Neutron Powder Diffraction (중성자분말회절법을 이용한 흑운모의 Rietveld Structure Refinement)

  • 전철민;김신애;문희수
    • Economic and Environmental Geology
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • The crystal structure of biotite-1M from Bancroft, Ontario, was determined by Rietveld refinement method using high-resolution neutron powder diffraction data at -26.3$^{\circ}C$, 2$0^{\circ}C$, 30$0^{\circ}C$, $600^{\circ}C$, 90$0^{\circ}C$. The crystal structure has been refined to a R sub(B) of 5.06%-11.9% and S (Goodness of fitness) of 2.97-3.94. The expansion rate of a, b, c unit cell dimensions with elevated temperature linearly increase to $600^{\circ}C$. The expansivity of the c dimension is $1.61{\times}10^{40}C^{-1}$, while $2.73{\times}10^{50}C^{-1}$ and $5.71{\times}10^{-50}C^{-1}$ for the a and b dimensions, respectively. Thus, the volume increase of the unit cell is dominated by expansion of the c axis as increasing temperature. In contrast to the trend, the expansivity of the dimensions is decreased at 90$0^{\circ}C$. It may be attributed to a change in cation size caused by dehydroxylation-oxidation of $Fe^{2+}$ to $Fe^{3+}$ in vacuum condition at such high temperature. The position of H-proton was determined by the refinement of diffraction pattern at low temperature (-2.63$^{\circ}C$). The position is 0.9103${\AA}$ from the O sub(4) location and located at atomic coordinates (x/a=0.138, y/b=0.5, z/c=0.305) with the OH vector almost normal to plane (001). According to the increase of the temperature, $\alpha$* (tetrahedral rotation angle), $t_{oct}$ (octahedral sheet thickness), mean distance increase except 90$0^{\circ}C$ data. But the trend is less clearly relative to unit cell dimension expansion because the expansion is dominant to the interlayer. Also, ${\Psi}$ (octahedral flattening angle) shows no trends as increasing temperature and it may be because the octahedron (M1, M2) is substituted by Mg and Fe.

  • PDF

Comparison of Radiologic Parameters between Weight Bearing Affected Both Ankle and Single Ankle in Ankle Exam (체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교)

  • Cha, Sangyoung;Shin, Jaehan;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.603-610
    • /
    • 2016
  • This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was $87.24^{\circ}$, TT was $6.44^{\circ}$, TMM was $26.76^{\circ}$, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was $88.93^{\circ}$, TT was $2.41^{\circ}$, TMM was $19.77^{\circ}$, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was $87.25^{\circ}$, TT was $5.71^{\circ}$, TMM was $23.92^{\circ}$, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was $3.19^{\circ}$, TMM $21.45^{\circ}$, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.

The Study on the Class Difficulty of Elementary Pre-service Teachers' Seasonal Change Unit (초등예비교사의 계절변화 단원에 대한 수업곤란도 연구)

  • Soon-shik Kim
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.16 no.3
    • /
    • pp.340-350
    • /
    • 2023
  • This study analyzed the difficulty level of class on the seasonal change unit for 84 students at a university of education. The conclusions of this study are as follows. First, if we first present the four topics that make up the seasonal changes in elementary science, the subjects that have the greatest difficulty in teaching for prospective elementary school teachers are 'Why do seasonal changes occur?' (Teaching difficulty level 4.05), 'The sun changes depending on the season' What is the difference between the southern altitude and the length of day and night?' (difficulty level of class, 3.12), 'What is the relationship between the altitude of the sun, length of shadow, and temperature during the day?' (difficulty level of class, 2.85), 'How does the temperature change depending on the season?' (class difficulty level 2.80). As a result, in the elementary science season change unit, the class on the four topics 'Why do seasons change?', which is classified as a class topic that requires the concept of spatial perception, showed a higher level of class difficulty than other units. Second, in the seasonal change unit, various factors of class difficulty appeared depending on the class topic. When pre-service elementary school teachers look at the factors that make class difficult when teaching a lesson on seasonal changes in order of frequency, 42 (50%) said 'Experimental instruction for comparing the altitude of solar masculine according to the tilt of the axis of rotation', followed by 'Solar masculine'. 38 people (45%) answered 'Difficulty in explaining mid-high altitude and the length of day and night', 27 people (32%) answered 'Difficulty in explaining the concept of mid-high altitude', and 24 people (32%) answered 'Difficulty in explaining seasonal changes in the sun's position.' 29%), 20 people (24%) said 'Explain the reasonable reason why the height of the light should be adjusted when measuring the solar altitude', and 16 people (19%) said 'It is difficult to explain the reason for the discrepancy between the solar altitude and the maximum temperature'. ), 'difficulties in measuring sand (ground) temperature' were mentioned by 12 people (14%). Third, when analyzing the factors of class difficulty, there were more curriculum factors than teacher factors. In this context, the exploratory activities on 'Why do seasonal changes occur?', the fourth topic of the seasonal change unit in which elementary school pre-service teachers showed the greatest difficulty in teaching, need improvement in terms of the curriculum.