• Title/Summary/Keyword: Rotating Source

Search Result 245, Processing Time 0.032 seconds

Off-Line PD Diagnosis for Stator Winding of Rotating Machines Using a UWB Sensor

  • Lwin, Kyaw-Soe;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • We studied partial discharge detection by sensing electromagnetic waves emitted from the partial discharge source in an HV Rotating Machine using a UWB sensor. In this study, we design a new type of compact low frequency UWB sensor based on micro-strip technology. We also perform many experiments of offline and dismantled testing compared with the existing HFCT on stator winding of the HV generator. We mention the detailed design of a new compact UWB sensor along with the time domain PRPD pattern and frequency domain results of partial discharge in the stator winding of a 6.6kV rotating machine by offline testing performed in a laboratory.

A Study on an Electro-Magnetic System far Arc Rotating in MIAB Welding (MIAB용접에서 아크 회전을 위한 전자기 시스템에 관한 연구)

  • 최동혁;김재웅
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.391-398
    • /
    • 2001
  • MIAB welding method uses a rotating arc as its heat source and is known to be efficient in pipe butt welding. The arc is rotated around the weld line by the electro-magnetic force resulting from the interaction of arc current and magnetic field. This paper is concerned with the experiment of initial stage for process control, monitoring for weld quality, and the design of coil system which is efficient of flux generation and concentration. A coil system for the generation of magnetic flux was designed and constructed. Magnetic flux density and arc rotating behavior are important factors in MIAB welding, so the relations between these factors and process parameters were investigated. Various experiments were performed for the steel pipes(48.1mm O.D and 2.0mm thickness). The magnetic flux density is increased by increasing exciting current and decreasing gap size. The maximum of arc rotating frequency is affected by exciting current and gap size. However, the variations of arc rotating frequency during welding and then the melting process are mainly influenced by welding current. Thus, it is considered that the results of this study can be used as important data on the monitoring for weld quality and the design of efficient coil system.

  • PDF

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Speed Control of the Motor in Automatic Control Using the Thyristor (싸이리스터에 의한 전동기 속도의 자동제어에 관한 연구)

  • Min Ho Park
    • 전기의세계
    • /
    • v.19 no.2
    • /
    • pp.6-11
    • /
    • 1970
  • For the variable speed in automatic control, this paper describes, at first, performance equations of an induction motor which has the free rotating stator. This motor with rotating stator has a speed control factor itself by equivalent variable frequency in stator side. Secondly, an additional invertor source on the rotor slip ring serves the purpose of improving the speed control factor. The advantages decribed above permit to control the speed continuosly from zero to maximum allowable speed with low energy of thyristor a feed-back device may be used for speed stabilization under variable load.

  • PDF

Identification of fault signal for rotating machinery diagnosis using Blind Source Separation (BSS) (BSS를 이용한 회전 기계 진단 신호 분석)

  • Seo, Jong-Soo;Lee, Jeong-Hak;J. K. Hammond
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.839-845
    • /
    • 2003
  • This paper introduces multichannel blind source separation (BSS) and multichannel blind deconvolution (MBD) based on higher order statistics of signals from convolutive mixtures. In particular, we are concerned with the case that the number of inputs is the same as the number of outputs. Simulations for two input two output cases are carried out and their performances are assessed. One of the major applications of those sequential algorithms (BSS and MBD) is demonstrated through the fault signal detection from only a single measurement of rotating machine, which offers a certain degree of practicability in the engineering field such as machine health monitoring or condition monitoring.

  • PDF

Effect of inclined load on transversely isotropic magneto thermoelastic rotating solid with time harmonic source

  • Lata, Parveen;Kaur, Iqbal
    • Advances in materials Research
    • /
    • v.8 no.2
    • /
    • pp.83-102
    • /
    • 2019
  • The present research deals with the time harmonic deformation in transversely isotropic magneto thermoelastic solid with two temperature (2T), rotation and without energy dissipation due to inclined load. Lord-Shulman theory has been formulated for this mathematical model. The entire thermo-elastic medium is rotating with a uniform angular velocity. The Fourier transform techniques have been used to find the solution to the problem. The displacement components, stress components and conductive temperature distribution with the horizontal distance are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. The effect of time harmonic source and rotation is depicted graphically on the resulting quantities.

Characteristics of $CH_4$ Decomposition by Plasma (플라즈마 이용 메탄 분해 특성)

  • Kim, Kwan-Tae;Lee, Dae-Hoon;Cha, Min-Suk;Ryu, Jeong-In;Song, Young-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.4
    • /
    • pp.24-32
    • /
    • 2005
  • Various types of plasma source applied in $CH_4$ decomposition process are compared. DBD by pulse and AC power, spark by pulse and AC power, rotating arc and hollow cathode plasma are chosen to be compared. The results show that $CH_4$ conversion per given unit power is relatively high in hollow cathode plasma and rotating arc that induces rather high temperature condition and that is why both thermal dehydration and plasma induced decomposition contribute for the overall process. In case of DBD wherein high temperature electron and low temperature gas molecule coexist, the process shows low conversion rate, for in rather low temperature condition the contribution of thermal dehydration is lowered. Selectivity of $C_2H_6$ and $C_2H_2$ is shown to be a good parameter of the relative contribution of plasma chemistry in the overall process. From the results we concluded that required condition of plasma source for a cost effective and high yield $CH_4$ decomposition is to have characteristics of both thermal plasma and non thermal plasma in which temperature is high above a certain threshold state for thermal dehydration and electron induced collision is maximized in the same breath.

  • PDF