• Title/Summary/Keyword: Rotated Z-axis

Search Result 15, Processing Time 0.02 seconds

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

Changes of lateral cephalometric values according to the rotation of head (두부회전에 따른 측모두부방사선 계측치의 변화)

  • Kim, Kwang-Soo;Hwang, Mee-Sun;Choi, Eui-Hwan;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.53-66
    • /
    • 2000
  • This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

  • PDF

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.