• Title/Summary/Keyword: Rotary

Search Result 2,347, Processing Time 0.034 seconds

An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a (대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구)

  • Youn, Young;Chung, Jin-Taek;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

Suggestion of Test Apparatus for Reliability Evaluation of a Rotary Compressor with a Short-Cycle (로터리 압축기용 Short-Cycle 신뢰성 시험장치 제안)

  • Lee, Tae-Gu;Lee, Sang-Jae;Kim, Hyun-Woo;Kim, Sang-Hyun;Lee, Jae-Heon;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.584-589
    • /
    • 2006
  • In this paper, a test apparatus for reliability evaluation of a rotary compressor has been suggested with a short-cycle concept. $CO_2$ refrigerant is adopted for this cycle to avoid phase change during cycle operation. Evaporator is not necessary in short-cycle. Utilizing a short-cycle, the test apparatus was built on the purpose of evaluating the reliability of each rotary compressor on the conveyer belt of the factory. The primary validation of the test apparatus is discussed by analyzing the experimental heat balance data. Additional validation was performed through the overload continuous operation test where the wear rate of the $CO_2$ short-cycle was found to similar to that of the R22 normal-cycle. The reliability evaluation test apparatus with a short-cycle in present investigation was found simple and efficient in the view of reducing sample numbers, costs, and test time in analyzing the reliability of rotary compressors.

  • PDF

Influence of reciprocating and rotary instrumentation on microbial reduction: a systematic review and meta-analysis of in vitro studies

  • Selen Kucukkaya Eren;Emel Uzunoglu-Ozyurek;Sevilay Karahan
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.19.1-19.12
    • /
    • 2021
  • Objectives: The purpose of this study was to conduct a systematic review and meta-analysis of in vitro studies regarding the effectiveness of reciprocating and rotary instrumentation on microbial reduction in root canals. Materials and Methods: PubMed, Scopus, Web of Science, the Cochrane Library, and the gray literature were searched through December 2019. Studies comparing the influence of reciprocating and rotary instrumentation on the removal of microorganisms from root canals that quantified the antimicrobial effect were included. Data extraction was completed using a systematic form for data collection. The risk of bias of the studies was evaluated. Standardized mean differences (SMDs) and confidence intervals (CIs) were calculated using a random effects meta-analysis. Results: Seventeen in vitro studies were included in this systematic review, of which 7 provided adequate data for inclusion in the meta-analysis. Both reciprocating and rotary systems were similarly effective in reducing the microbial load in infected root canals (SMD [95% CI], 0.0481 [-0.271, 0.367]). Three studies showed a low risk of bias, whereas most of the studies (82%) presented a medium risk. Conclusions: Although both techniques decrease the microbial content (with reductions of 23.32%-88.47% and 23.33%-89.86% for reciprocating and rotary instrumentation, respectively), they are not able to provide complete disinfection of root canals.

Wear Test for Rotary Compressor using Alternative Refrigerants (대체냉매를 사용한 로타리 압축기의 마모시험)

  • 좌성훈;백충국;장선태;오상경
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1995.06b
    • /
    • pp.28-37
    • /
    • 1995
  • To protect the ozone layer depeletion the CFC (chlorofluorocarbon). HCFC(hydrochlorofluorocarbon) refrigerants will be replaced with HFCs (hydro-fluorocarbon) as an alternative refrigerant. In recent years a good deal of effort has been made to develop new compressors which are compatible to the new referigent. This paper focused on developing accelerated screening test for predicting tribological characteristics of the rotary compressor in atmosphere of R407C as an alternative refrigerant with polyolester lubricant. Falex wear test machine with high pressure chamber has been used to simulate friction and wear behavior of the common contact geometries found in rotary compressors.

  • PDF

Rotary Inverted Pendulum Control Using Single Neuron With Weights of PID Parameters (PID 계수를 가중치로 가진 단일뉴런을 이용한 Rotary Inverted Pendulum 제어)

  • 이정훈;정성부;엄기환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2569-2572
    • /
    • 2003
  • In this paper, we Proposed the inverted pendulum control method using single neuron neural network that have weights as PID parameters. The proposed method has three inputs(proportion, integration, differentiation term of the error), and uses weights as P, I, D parameters. In order to verify the effectiveness of the proposed method, we experimented on the rotary inverted pendulum with load effect disturbance. The results showed the effectiveness and robustness of the proposed pendulum controller.

  • PDF

Manufacture of Rotary Compressor Side Block using CAD/CAM (CAD/CAM을 활용한 로터리 압축기의 사이드 블록 제작)

  • Chio Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.555-559
    • /
    • 2005
  • The object of this study is in introduce CAD/CAM application technology for manufacturing rotary compressor side block. CAM systems consist of CAD(Solidworks), CAM(I-MASTER) software and CNC milling machine. CAM software is used to simulate the tool path and generate G-code for CNC programming.

  • PDF

Design of A Rotary MR Damper (로터리 MR댐퍼의 설계)

  • Lee, Jong-Seok;Lee, Ji-Ung;Baek, Woon-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.945-950
    • /
    • 2007
  • This paper presents the design study of a rotary MRF(Magneto-Rheological Fluid) damper that can be conveniently used in the joints to control the damping torques. The basic design concept is to determine the geometric design variables allowing the magnetic flux to flow across the same sectional areas under volume constraint condition. The effects of each design variables for generating the torques were investigated by magnetic field analyses.

  • PDF

Identification of Abnormal Compressor using Wavelet Transform (Wavelet 변환에 의한 압축기의 이상상태 식별)

  • 정지홍;이기용;김정석;이감규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.361-364
    • /
    • 1995
  • Wavelet Transform is a new tools for signal processing, such as data compressing extraction of parameter for Reconition and Diagnostics. This transform has an advandage of a good resolution compared to Fast Fourier Transform (FFT) In this study, we employ the wavelet transform for analysis of Acoustic Emission raw signal generated form rotary compressor. In abnormal condition of rotary compressor, the state of operating condition can be classified by analizing coefficient of wavelet transformed signal.

  • PDF

Study of Muffler for Rotary Compressor by Taguchi Method Viewpoint (회전형 압축기용 머플러의 연구(1) : 다꾸찌 기법 관점에서)

  • 박성근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.548-553
    • /
    • 1998
  • The specific noise level of 18 rotary compressor mufflers were measured and these data were analyzed by the Taguchi robust design method and the neural network. The optimal design value obtained by the neural network generally showed good agreement with that by the Taguchi method. The effects of eight important design variables on the specific noise level were discussed.

  • PDF

The evaluation for the operation surface mounters using a dynamic network (동적 네트워크를 이용한 표면실장기 운영 평가)

  • 이달상
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.570-573
    • /
    • 1996
  • The evaluation test for the operation of rotary type surface mounters which consist of the reel axis, the index table and the X-Y table, has been performed by comparing the new method with the old one in only fields. Because the problem seeking for the optimal operation of rotary type surface mounters, is NP complete, it is almost impossible to get the optimal solutions of large problems. This paper deals with a dynamic network modeling, which can reduce the effort, the cost, and the time used for the performance test of rotary type surface mounters.

  • PDF