• Title/Summary/Keyword: Root mean square (RMS)

Search Result 495, Processing Time 0.026 seconds

Effect of Static Recovery and Dynamic Recovery on the Cardiopulmonary Variables, Lower Extremity Muscle Activity after Progressive Resistance Exercise to Maximal Point

  • Yoon, Jung-Gyu;Kim, Ga-Yeong;Kim, Min-A;Lee, Seung-Mi;Kwon, Seung-Min;Yoo, Kyung-Tae;Cho, Joon-Haeng;Choi, Jung-Hyun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.1
    • /
    • pp.237-243
    • /
    • 2011
  • This study was to examine on the respiratory variables, heart rate and muscle activity between the static recovery and dynamic recovery after progressive resistance exercise to maximal point. Subjects were 15 students enrolled in N University. All were tested two times (static recovery and dynamic recovery) and were requested to perform a walking on a treadmill after progressive resistance exercise to maximal point. Electromyography(EMG) was used to monitor the muscle activity(TA: Tibialis Anterior, MG: Medial Gastrocnemius) during gait. CPEX-1 was used to measure the respiratory variables and heart rate. The dynamic recovery group was shown the significant lower heart rate than that of static recovery group at during gait. Respiratory rate showed statistically a significant difference. Electromyography(RMS, root mean square) showed a non-significant difference. But the dynamic recovery group of muscle activity was found highly in TA and MG. This study indicated that the dynamic recovery method evidenced more faster than the static recovery method. And this type of dynamic rest by walking can be a help of recovery after exercise.

Development of a hygroscopic polymer-coated QCM humidity sensor and its characteristics (감습 고분자막이 코팅된 수정미소저울 습도센서 제작 및 특성연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il;Nham, Hyun-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.395-401
    • /
    • 2005
  • A highly stable quartz crystal microbalance (QCM) that showed a stability of frequencies and exhibited a very low noise level has been developed. The long-term drift was <0.05 Hz/h over a period of 10 h, and the short-term rms (root mean square) noise was <0.015 Hz. Our QCM sensor was used as a humidity sensor employing a poly(methyl methacrylate) (PMMA) polymer film as a hygroscopic layer, which showed good characteristics in the relative humidity (RH) range of $2{\sim}90%$ RH. Comparing the characteristics of the QCM sensor with those of other types of humidity sensors employing PMMA film as a hygroscopic layer, and with other QCM sensors employing other hygroscopic layers is represented.

Comparison of Local and Global Fitting for Exercise BP Estimation Using PTT (PTT를 이용한 운동 중 혈압 예측을 위한 Local과 Global Fitting의 비교)

  • Kim, Chul-Seung;Moon, Ki-Wook;Eom, Gwang-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2265-2267
    • /
    • 2007
  • The purpose of this work is to compare the local fitting and global fitting approaches while applying regression model to the PTT-BP data for the prediction of exercise blood pressures. We used linear and nonlinear regression models to represent the PTT-BP relationship during exercise. PTT-BP data were acquired both under resting state and also after cycling exercise with several load conditions. PTT was calculated as the time between R-peak of ECG and the peak of differential photo-plethysmogram. For the identification of the regression models, we used local fitting which used only the resting state data and global fitting which used the whole region of data including exercise BP. The results showed that the global fitting was superior to the local fitting in terms of the coefficient of determination and the RMS (root mean square) error between the experimental and estimated BP. The nonlinear regression model which used global fitting showed slightly better performance than the linear one (no significant difference). We confirmed that the wide-range of data is required for the regression model to appropriately predict the exercise BP.

Replication of Automotive Vibration Target Signal Using Iterative Learning Control and Stewart Platform with Halbach Magnet Array (반복학습제어와 할바흐 자석 배열 스튜어트 플랫폼을 이용한 차량 진동 신호 재현)

  • Ko, Byeongsik;Kang, SooYoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.438-444
    • /
    • 2013
  • This paper presents the replication of a desired vibration response by iterative learning control (ILC) system for a vibration motion replication actuator. The vibration motion replication actuator has parameter uncertainties including system nonlinearity and joint nonlinearity. Vehicle manufacturers worldwide are increasingly relying on road simulation facilities that put simulated loads and stresses on vehicles and subassemblies in order to reduce development time. Road simulation algorithm is the key point of developing road simulation system. With the rapid progress of digital signal processing technology, more complex control algorithms including iterative learning control can be utilized. In this paper, ILC algorithm was utilized to produce simultaneously the six channels of desired responses using the Stewart platform composed of six linear electro-magnetic actuators with Halbach magnet array. The convergence rate and accuracy showed reasonable results to meet the requirement. It shows that the algorithm is acceptable to replicate multi-channel vibration responses.

Effect of N2/Ar flow rates on Si wafer surface roughness during high speed chemical dry thinning

  • Heo, W.;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.128-128
    • /
    • 2010
  • In this study, we investigated the evolution and reduction of the surface roughness during the high-speed chemical dry thinning process of Si wafers. The direct injection of NO gas into the reactor during the supply of F radicals from NF3 remote plasmas was very effective in increasing the Si thinning rate, due to the NO-induced enhancement of the surface reaction, but resulted in the significant roughening of the thinned Si surface. However, the direct addition of Ar and N2 gas, together with NO gas, decreased the root mean square (RMS) surface roughness of the thinned Si wafer significantly. The process regime for the increasing of the thinning rate and concomitant reduction of the surface roughness was extended at higher Ar gas flow rates. In this way, Si wafer thinning rate as high as $20\;{\mu}m/min$ and very smooth surface roughness was obtained and the mechanical damage of silicon wafer was effectively removed. We also measured die fracture strength of thinned Si wafer in order to understand the effect of chemical dry thinning on removal of mechanical damage generated during mechanical grinding. The die fracture strength of the thinned Si wafers was measured using 3-point bending test and compared. The results indicated that chemical dry thinning with reduced surface roughness and removal of mechanical damage increased the die fracture strength of the thinned Si wafer.

  • PDF

Retrieval of surface parameters in tidal flats using radar backscattering model and multi-frequency SAR data

  • Choe, Byung-Hun;Kim, Duk-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.225-234
    • /
    • 2011
  • This study proposes an inversion algorithm to extract the surface parameters, such as surface roughness and soil moisture contents, using multi-frequency SAR data. The study areas include the tidal flats of Jebu Island and the reclaimed lands of Hwaong district on the western coasts of the Korean peninsula. SAR data of three frequencies were accordingly calibrated to provide precise backscattering coefficients through absolute radiometric calibration. The root mean square (RMS) height and the correlation length, which can describe the surface roughness, were extracted from the backscattering coefficients using the inversion of the Integral Equation Method (IEM). The IEM model was appropriately modified to accommodate the environmental conditions of tidal flats. Volumetric soil moisture was also simultaneously extracted from the dielectric constant using the empirical model, which define the relations between volumetric soil moistures and dielectric constants. The results obtained from the proposed algorithm were verified with the in-situ measurements, and we confirmed that multi-frequency SAR observations combined with the surface scattering model for tidal flats can be used to quantitatively retrieve the geophysical surface parameters in tidal flats.

Plasma Etching을 이용한 RF-Magnetron Sputtering 방법으로 제작된 PTFE 발수 특성

  • Baek, Cheol-Heum;Jang, Ji-Won;Bang, Seung-Gyu;Seo, Seong-Bo;Kim, Hwa-Min;Bae, Gang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.273-273
    • /
    • 2012
  • 최근 스마트 윈도우, 자가세정(Self-Cleaning), 김서림방지(Anti-Fogging), 디스플레이 표시장치, 대전방지 코팅 등 다각적으로 활용이 가능한 PTFE (Ploytetrafluoroethylene)를 Sol-gel, Sputtering, Spin-Coating, CVD (Chemical vapor deposition)방법을 이용하여 낮은 표면에너지와 나노사이즈의 표면 거칠기를 가지는 $150^{\circ}$ 이상의 초-발수성 표면에 대한 많은 연구가 진행되고 있다. 본 실험에서는 영구자석을 이용한 고밀도 플라즈마로 높은 점착성과, 균일한 박막 및 대 면적 공정이 가능한 RF-magnetron sputtering방법을 이용하여 Plasma etching으로 표면적의 거칠기와 낮은 표면에너지를 만든 뒤, 발수특성을 가진 PTFE를 증착하여 접촉각 변화와 구조적 및 광학적 특성을 측정하였다. AFM (Atomic Force Microscope)측정결과 100 w에서 가장 높은 1.7 nm의 RMS(Root mean square)값이 측정되었고, 접촉각 측정결과 Plasma etched glass는 25 w에서 125 w로 증가함에 따라 친수성을 나타내었으며, 100 w에서 가장 낮은 $15^{\circ}$의 접촉각을 나타내었다. PTFE박막을 증착하였을 때는 100 w에서 $150^{\circ}$의 초발수 특성을 나타내었고, 투과율 측정 결과 85%이상의 높은 투과율을 나타내었다. Plasma etching을 이용한 PTFE 발수 특성은 비가 오면 자동으로 이물질이 씻겨 내리는 자동차 유리등의 개발이 가능하고, 높은 투과율이 요구되는 액정표시장치(LCD)같은 차세대 대형 디스플레이의 표면 코팅에 사용이 가능 할 것이라 사료된다. 본 연구는 중소기업청에서 지원하는 2011년도 산학연 공동기술개발 지원사업의 연구수행으로 인한 결과물임을 밝힙니다.

  • PDF

Steady State Kalman Filter based IMM Tracking Filter for Multi-Target Tracking (다중표적 추적을 위한 정상상태 칼만필터 기반 IMM 추적필터)

  • 김병두;이자성
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.71-78
    • /
    • 2006
  • When a tracking filter may be designed in the Cartesian coordinate, the covariance of the measurement errors varies according to the range and the bearing of an interested target. In this paper, interacting multiple model based tracking filter is formulated in the Cartesian coordinate utilizing the analytic solution of the steady state Kalman filter, which can be able to consider the variation of the measurement error covariance. 100 Monte Carlo runs performed to verify the proposed method. The performance of the proposed method is compared with the conventional fixed gain and Kalman filter based IMM tracking filter in terms of the root mean square error. The simulation results show that the proposed approach meaningfully reduces the computation time and provides a similar tracking performance in comparison with the conventional Kalman filter based IMM tracking filter.

Spray Behavior Characteristics of Injector Used for HC-DeNOx Catalyst System in the Transparent Exhaust Manifold (모사 배기관 내 HC-DeNOx 촉매용 인젝터의 분무 거동 특성)

  • Lee, Dong-Hoon;Oh, Jung-Mo;Jeong, Hae-Young;Lee, Ki-Hyung;Yeo, Kwon-Gu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.54-60
    • /
    • 2007
  • A new method that optimizes a control of hydrocarbon (HC) addition to diesel exhaust gas for HC type DeNOx catalyst system has been developed. These catalysts are called as the HC-DeNOx catalyst in this paper. The system using HC-DeNOx catalyst requires a resonable quantity of hydrocarbons addition in the inlet gas of the catalyst, because the HC concentration in a diesel engine is so low that the HC is not sufficient for NOx conversion. Generally ambient temperature in the exhaust manifold is $250{\sim}350^{\circ}C$, so spray behavior in this case is different from that of any other condions. This research shows spray behavior of injected hydrocarbons in the transparent exhaust manifold.

Health monitoring of steel structures using impedance of thickness modes at PZT patches

  • Park, Seunghee;Yun, Chung-Bang;Roh, Yongrae;Lee, Jong-Jae
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.339-353
    • /
    • 2005
  • This paper presents the results of a feasibility study on an impedance-based damage detection technique using thickness modes of piezoelectric (PZT) patches for steel structures. It is newly proposed to analyze the changes of the impedances of the thickness modes (frequency range > 1 MHz) at the PZT based on its resonant frequency shifts rather than those of the lateral modes (frequency range > 20 kHz) at the PZT based on its root mean square (RMS) deviations, since the former gives more significant variations in the resonant frequency shifts of the signals for identifying localities of small damages under the same measurement condition. In this paper, firstly, a numerical analysis was performed to understand the basics of the NDE technique using the impedance using an idealized 1-D electro-mechanical model consisting of a steel plate and a PZT patch. Then, experimental studies were carried out on two kinds of structural members of steel. Comparisons have been made between the results of crack detections using the thickness and lateral modes of the PZT patches.