• Title/Summary/Keyword: Root coverage

Search Result 124, Processing Time 0.033 seconds

A Study on the Performance of Causal Links between Error Causes: Application to Railroad Accident Cases

  • Kim, Dong San;Yoon, Wan Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.535-540
    • /
    • 2013
  • Objective: The aim of this study is to evaluate the effectiveness and efficiency of causal links between various error causes in human error analysis. Background: As finding root causes of human error in safety-critical systems is often a cognitively demanding and time-consuming task, it is particularly necessary to develop a method for improving both the quality and efficiency of the task. Although a few methods such as CREAM have suggested causal linking between error causes as a means to enhance the quality and efficiency of human error analysis, no published research to date has evaluated the performance of the causal links. Method: The performance of the CREAM links between error causes were evaluated with 80 railway accident investigation reports from the UK. From each report, errorneous actions of operators were derived, and for each error, candidate causes were found by following the predefined links. Two measures, coverage and selectivity, were used to evaluate the effectiveness and efficiency of the links, respectively. Results: On average, 96% of error causes actually included in the accident reports were found by following the causal links, and among the total of 121 possible error causes, the number of error causes to be examined further was reduced to one-tenth on average. As an additional result of this work, frequent error causes and frequently used links are provided. Conclusion: This result implies that the predefined causal links between error causes can significantly reduce the time and effort required to find the multiple levels of error causes and their causal relations without losing the quality of the results. Application: The CREAM links can be applied to human error analysis in any industry with minor modifications.

Use Impacts on Environmental Deteriorations on and around Trails in Naesorak District of Soraksan National Park (설악산국립공원 내설악지구 등산로의 훼손 및 주연부식생)

  • 권태호;오구균;김보현
    • Korean Journal of Environment and Ecology
    • /
    • v.11 no.4
    • /
    • pp.523-534
    • /
    • 1998
  • Six trails of Naesorak(west Sorak) district of Soraksan National Park were selected to investigate the use impacts on environmental edterioration of trail according to the different amount of use. The entire width, and slope of trail as the trail condition surveyed at the total of 132 points were significantly varied with the amount of use. Major deterioration types of trail were rock-exposure, root-exposure, deepening and divergence in order of frequency. Deteriorated points were significantly different in trail conditions from non-deteriorated points, and these latter generally appeared at the lowed altituede than the former on each trail. Naesorak district still seemed to have poorer use-impacts than Oesarak(east sorak) district. The dominant species in upper layer of trail edge vegetation differed from trail to trail, but in shrub layer Lespedeza maximowiczii, lindera obutsiloba for valley trail and Rhododendron schlipenbavhii for slope trail. The species diversity and coverage of shrub layer in trail edge were the highest on the Ose'am trail and each trail was dissimilar in species composition of shrub layer of edge vegetation.

  • PDF

Evaluation of critical tractive forces of vegetation mats enhanced with biopolymer mixed soil (바이오폴리머 혼합토와 결합된 식생매트의 한계 소류력 평가)

  • Lee, Du Han;Kim, Myounghwan
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.3
    • /
    • pp.167-179
    • /
    • 2020
  • Recently, new levee material has been developed to enhance natural soil strength and vegetation growth using biopolymer. In the study, critical tractive force of vegetated mats mixed with biopolymer mixed soil has been evaluated to apply the mixed soil to levee construction material. The mixed soil has been produced by mixing beta-glucan, clay, and sand. Full scale test bodies have been constructed with 3 cm thick of the mixed soil. Total 4 test bodies have been constructed and experimented. Critical tractive forces have been evaluated by observation and measurement of failure conditions and soil loss. Although performance of the vegetated revetments are affected by vegetation coverage conditions, the critical tractive forces are shown about 40 N/㎡ and the critical velocities are shown about 4 m/sec by full scale experiment. Erosion resistance is also enhanced by combination of root and net with mat materials.

Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs (LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Evaluation of Stability and Deterioration Characteristics for the Rock-carved Standing Buddha Triad in Gyeongju Seoak-dong, Korea (경주 서악동 마애여래삼존입상의 손상특성 및 안정성 평가)

  • Lee, Chan Hee;Choie, Myoungju
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.137-150
    • /
    • 2021
  • The rock-carved standing Buddha triad in Seoak-dong is a large stone Buddha statue of the Unified Silla era (AD 676 to 935) in ancient Korea, built near the top of the southeastern side of mountain Seondosan in Gyeongju, is characterized by its locational importance, the powerful Amitabha and the gentle sculptural technique of the Bodhisattva. In particular, Amitabha Buddha in andesite rock slope with biotite granite pedestal and two Bodhisattva parallel made by alkali granites seems to express the dignity through the color and texture of the stones. In the Amitabha Buddha, deterioration characteristics are accelerating due to the combination of various joint systems, instability of the slopes and relaxation by the root pressure of plants occurring at the top. In addition, physical properties have deteriorated owing to the increase of discontinuous surfaces as joints, cracks and scalings, and the coverage of algae and lichen is also high. Therefore, deterioration degree in Buddha triad is accelerated due to the physical weathering characteristics from natural rock mass and various biological invasion.

Impact of different agitation methods on smear layer cleaning of mesial canals with accentuated curvature

  • Abel Teves Cordova;Murilo Priori Alcalde;Michel Espinosa Klymus;Leonardo Rigoldi Bonjardim;Rodrigo Ricci Vivan;Marco Antonio Hungaro Duarte
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.12.1-12.10
    • /
    • 2024
  • Objectives: This study evaluated the impact of different methods of irrigant agitation on smear layer removal in the apical third of curved mesial canals of 3 dimensionally (D) printed mandibular molars. Materials and Methods: Sixty 3D-printed mandibular second molars were used, presenting a 70° curvature and a Vertucci type II configuration in the mesial root. A round cavity was cut 2 mm from the apex using a trephine of 2 mm in diameter, 60 bovine dentin disks were made, and a smear layer was formed. The dentin disks had the adaptation checked in the apical third of the teeth with wax. The dentin disks were evaluated in environmental scanning electron microscope before and after the following irrigant agitation methods: G1(PIK Ultrasonic Tip), G2 (Passive Ultrasonic Irrigation with Irrisonic- PUI), G3 (Easy Clean), G4 (HBW Ultrasonic Tip), G5 (Ultramint X Ultrasonic tip), and G6 (conventional irrigation-CI) (n = 10). All groups were irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid. Results: All dentin disks were 100% covered by the smear layer before treatment, and all groups significantly reduced the percentage of the smear layer after treatment. After the irrigation protocols, the Ultra-X group showed the lowest coverage percentage, statistically differing from the conventional, PIK, and HBW groups (p < 0.05). There was no significant difference among Ultramint X, PUI-Irrisonic, and Easy Clean (p > 0.05). None of the agitation methods could remove the smear layer altogether. Conclusions: Ultramint X resulted in the most significant number of completely clean specimens.

The Vegetation Effect of under Neutralizing Layer Type on the Acid Drainage Slope (산성배수 비탈면의 중화층 종류에 따른 녹화효과)

  • Cho, Sung Rok;Kim, Jae Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.493-503
    • /
    • 2019
  • This study is composed of nine treatments [Control : "no neutralizing layer+vegetation layer" 3 cm, Treatment 1 : "no neutralizing layer+vegetation layer" 5 cm, Treatment 2 : "no neutralizing layer+vegetation layer" 7 cm, Treatment 3 :"neutralizing layer (cement 3 %)+ vegetation layer (cement 1 %)" 3 cm, Treatment 4 : "neutralizing layer (cement 3 %)+vegetation layer (cement 1 %)" 5 cm, Treatment 5 : "neutralizing layer (cement 3 %)+vegetation layer (cement 1 %)" 7 cm, Treatment 6 : "neutralizing layer [$(Ca{\cdot}Mg)CO_3$] +vegetation layer" 3 cm, Treatment 7 : "neutralizing layer [$(Ca{\cdot}Mg)CO_3$]+vegetation layer" 5 cm, Treatment 8 : "neutralizing layer [$(Ca{\cdot}Mg)CO_3$]+vegetation layer" 7 cm] to find out the vegetation effects according to neutralizing layer types of the acid drainage slope. There were no significant differences observed in soil hardness and soil moisture content of neutralizing layer type while highly difference of moisture content was observed according to the neutralizing and vegetation layer thickness. As for soil acidity, strong acid was shown in the control, treatment 1 and treatment 2. Neutralizing effects were outstanding in treatments of 3, 4, 5 (cement treatment group), 6, 7 and 8 (limestone treatment group). Concerning plants growth characteristics, surface coverage rates, number of germinating woody plants, plant height, and plant root status, there were excellent effects observed in the experimental groups mixed with cement (treatments 3, 4 and 5) and limestone (treatments 6, 7 and 8). At the initial stage, however, plant roots were negatively affected in cement layer treatments of 3, 4 and 5. However, no difference was shown in each layer thickness on the acid drainage slope whereas 3~5 cm thickness neutralizing layer was appropriate in consideration of economic feasibility.

Effect of Polymer, Calcium, Perlite and Chitosan in Soil Organic Amendment on Growth in Perennial Ryegrass (유기질 토양개량재에서 고분자 중합체, 칼슘, 펄라이트 및 키토산이 퍼레니얼 라이그래스의 생장에 미치는 효과)

  • Kim, Kyoung-Nam
    • Asian Journal of Turfgrass Science
    • /
    • v.26 no.1
    • /
    • pp.24-34
    • /
    • 2012
  • The study was carried out to investigate the effects of polymer, calcium, perlite and chitosan on the growth of perennial ryegrass (Lolium perenne L., PR) and to provide a basic information needed for their practical application when establishing garden, parks, athletic field and golf courses with these materials. A total of 24 treatment combinations were applied in the study. Treatments were made of water-swelling polymer (WSP), calcium, perlite and chitosan mixed in soil organic amendment (SOA). Germination rate, turfgrass coverage, turfgrass density and top growth were evaluated in PR under greenhouse conditions. Significant differences were observed for these growth characteristics among the treatments. Turfgrass density and plant height, evaluated on a weekly basis, varied with time after seeding. A proper mixing rate of WSP was considered to be lower 3% for the growth of PR with an exception of being below 6% for turfgrass density. Germination rate and early survival capacity were greatly influenced by calcium and chitosan among the elements of calcium, perlite, and chitosan. But there was little effect by perlite. Calcium and chitosan were most effective one for turfgrass density and coverage, respectively. Top leaf-growth was influenced by all three elements, but the greatest effect was highly linked with calcium. Chitosan was very effective in early germination and vertical leaf growth, as compared with the others. Future studies are required for measuring the effect of WSP, calcium, perlite and chitosan on the turf growth characteristics in root zone mixtures of sand+SOA before a practical field use.

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Treatment of Class II Furcation Involvements in Humans with Bioabsorbable Guided Tissue Regeneration Barriers (2급 치근분지부 병소에서의 생분해성 차폐막의 효과)

  • Lee, Hak-Churl;Han, Seoung-Min;Seol, Yang-Jo;Lee, Chul-Woo;Um, Heung-Sik;Chang, Beom-Suk;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.539-553
    • /
    • 1999
  • The purpose of this 6-months study was to compare the clinical and radiographic outcomes following guided tissue regeneration treating human mandibular Class II furcation defects with a bioabsorbable BioMesh barrier(test treatment) or a nonabsorbable ePTFE barrier(control treatment). Fourteen defects in 14 patients(mean age 44 years) were treated with BioMesh barriers and ten defects in 10 patients(mean age 48 years) with ePTFE barriers. After initial therapy, a GTR procedure was done. Following flap elevation, root planing, and removal of granulation tissue, each device was adjusted to cover the furcation defect. The flaps were repositioned and sutured to complete coverage of the barriers. A second surgical procedure was performed at control sites after 4 to 6 weeks to remove the nonresorbable barrier. Radiographic and clinical examinations(plaque index, gingival index, tooth mobility, gingival margin position, pocket depth, clinical attachment level) were carried out under standardized conditions immediately before and 6 months after surgery. Furthermore, digital subtraction radiography was carried out. All areas healed uneventfully. Surgical treatment resulted in clinically and statistically equivalent changes when comparisons were made between test and control treatments. Changes in plaque index were 0.7 for test and 0.4 for control treatments; changes in gingival index were 0.9 and 0.5. In both group gingival margin position and pocket depth reduction was 1.0mm and 3.0mm; clinical attachment level gain was 1.9mm. There were no changes in tooth mobility and the bone in radiographic evaluation. No significant(p${\leq }$0.05) difference between the two membranes could be detected with regard to plaque index, gingival index, gingival margin position, pocket depth, and clinical attachment level. In conclusion, a bioabsorbable BioMesh membrane is effective in human mandibular Class II furcation defects and a longer period study is needed to fully evaluate the outcomes.

  • PDF