• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.027 seconds

Development of a metal-halide lamp's electronic ballast (메탈핼라이드 집어등용 전자식 안정기 개발)

  • Park, Seong-Wook;Bae, Bong-Seong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.2
    • /
    • pp.116-125
    • /
    • 2013
  • Jigging and angling fishery is prevalent in the East Sea of Korea and this fishery needs many lamps to attract the fish. And the fishing boat uses 24~47 ballasts by the vessel's tonnage to turn on the fishing lamp. A 3.5kW magnetic-type ballast being currently used at many fishing boats can drive two 1.5kW metal-halide lamps. Meanwhile, this ballast has large weight (25kg) and volume. Therefore it is one of reason for the over-consumption of energy and the fire, resulted from overheat and electrical short, occurs occasionally because the ballast is installed at narrow and hot engine room. In addition, most of magnetic ballast has several problems such as periodic condenser replacement, low energy efficiency and making lamp short life, etc. So it is necessary to improve or develop newly the electronic ballast, which has to be smaller, lighter and more efficient. An electronic ballast was designed for the fishing boat by considering duration and electromagnetic interference in the study. Its weight and volume are respectably 40% and 66% compared to current ballast on the basis of PCB. The metal-halide lamp's spectrum of the designed ballast was nearly same to that of the current ballast in the test of lighting. In particular, the light stability was improved and there isn't any radio interference. As mentioned above, it is expected that the developed electronic ballast can replace current magnetic ballast because of many advantages related to energy-saving.

Study on the Thermal Conductivity and Viscosity of Ethanol with Carbon Nanotubes for the Development of a Heat Pipe Working Fluid (히트파이프 작동유체 개발을 위한 에탄올-탄소나노튜브 나노유체의 열전도도 및 점도 특성 연구)

  • An, Eoung-Jin;Park, Sung-Seek;Park, Yoon-Chul;Kim, Jong-Yoon;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.9-16
    • /
    • 2012
  • Nanofluids using Carbon Nanotubes have a excellent thermal characteristic. In this study, for increasing the efficiency of solar collector, the thermal conductivity and viscosity of Ethanol-Oxidized Multi-walled Carbon Nanofluids were measured. Nanofluids were manufactured by ultra-sonic dispersing Oxidized Multi-walled Carbon Nanotubes(OMWCNTs) in ethanol at the rates of 0.0005 ~ 0.1 vol%. The thermal conductivity and viscosity of manufactured nanofluids were measured at the low temperature($10^{\circ}C$), the room temperature($25^{\circ}C$) and the high temperature($70^{\circ}C$). For measuring thermal conductivity and viscosity, we used transient hot-wire method and rotational digital viscometer, respectively. As a result, under given temperature conditions, thermal conductivity of the 0.1 vol% nanofluids improved 33.74% ($10^{\circ}C$), 33.14% ($25^{\circ}C$) and 32.36% ($70^{\circ}C$), and its viscosity increased by 37.93% ($10^{\circ}C$), 31.92% ($25^{\circ}C$) and 29.42% ($70^{\circ}C$) than the base fluids.

Current status of clinical practice and associated factors with satisfaction among students in the department of Emergency Medical Service (일부 응급구조(학)과 학생의 병원임상실습 실태 및 만족도 관련요인)

  • Choi, Sung Soo;Park, Jong;Ryu, So Yeon;Han, Mi Ah
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.9-22
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate the current status of clinical practice and associated factors with satisfaction among students in the department of emergency medical service. Methods : The study subjects were 498 students who finished clinical practice course in 9 universities. General characteristics, current status of clinical practice, frequency of some medical procedure and practice satisfaction were collected using self-administered questionnaire. The association between clinical practice and satisfaction was tested by t-test, ANOVA and multiple regression analysis. Results : Of 498 students, 257 (51.6%) subjects were male and the mean age was $22.1{\pm}2.01$. The overall satisfaction score of clinical practice was $96.76{\pm}18.04$. Male students had higher satisfaction scores than that of female. The students who were satisfied with the emergency room practice wanted to work in hospital or fire station and they had a tendency to take paramedic as their lifelong career. The students preferred to practicing in the emergency department that hire the paramedic. Conclusion : Gender, grades, future jobs, occupational views, practical places, agency orientation, departments, and educators were associated with educational satisfaction. The practice program considering the results of this study will help to increase the educational satisfaction in students of emergency medical service.

A Study on the Conservation of Library Materials (도서관자료(圖書館資料) 보존(保存)에 관한 연구(硏究))

  • Kweon, Kie-Won
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.6 no.1
    • /
    • pp.179-213
    • /
    • 1984
  • The history of recording and conserving for maintenance the human's memory from ancient times to modern's has brought about a lot of changing process of the recorded information media with developing in culture, and each society has made important recorded materials in his library as essentially the social apparatus. But most of them that were damaged by factors of the natural disaster, humidity, temperature, light, fungi and insects in the library, and were resulted in deterioration and losing the numerous materials. For removing the inevitable phases repeated, there are studying for counterplan of the fundamental environment factors about preservation, restoration and chemical research of materials in advanced countries, but I get a few researches about protecting the cultural properties. Therefore I research the survey of the actual conditions on 72 university libraries centering around them, and then I have researched the collection rate 81 percent, 58 university libraries. (local : 35, in seoul : 23) As the result of this research, I propose the model of the environment factors of conserving the library materials. 1) To apply the equipment of processing the radiant energy to the new construction and buildings. 2) To remove factors that occur fungi and insects by facilities being controlled relative humility, temperature, and to equip the ventilation arrangement in the library. 3) To shelve all acquired and bound materials after proceeding the vacuum fumigator. 4) Those who want to enter into the library stack were surely taken in sterilzing their hands and shoes, and must put on the gown. 5) To use the vacuum dusting thing (machine) for removing the dust without spreading out the floor of the library at any time. 6) To set up the gas automatic fire extinguisher worked by smoke sensor. 7) To assist the research into the preservation, natures and environment of recorded materials, and to supply financial funds for librarian. 8) To hold regularly the workshop be able to educate the methods of preservation materials by the constant system. (Library Association) 9) To add to responsibilities on certification of preservation materials for librarian. 10) To hold the constant committee system in each library. 11) To keep up with the ideal environment (humidity, temperature, light, ventilation, etc.) of preservation materials in the arrangement room, and to put on the gown.

  • PDF

The Planning of Temporary Housing for Post Application of Mega Sports Facilities - Focused on the 2018 Winter Olympics - (메가스포츠시설의 사후 활용을 위한 임시주거 계획 - 2018평창동계올림픽을 중심으로 -)

  • Lee, Jong-Chan;Kang, Youn-Do;Kim, Byung-Sean
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.41-46
    • /
    • 2016
  • Purpose: This is a study on the planning of temporary housing for post application of Mega Sports facilities. The subject of the study is 2018 Pyeongchang Winter Olympics, which is to suggest building an alternative temporary housing using shipping containers(high cube), which solve the lack of accommodations and recycle temporary housing after Olympics, save money and be eco-friendly in Olympics. Method: This study includes this ; research on the a fact-finding survey about Mega sports facilities post application and demand survey on 2018 Pyeongchang Winter Olympics accomodations and an analysis about temporary housing plan. Furthermore we decided temporary housing building plan by analyzing residents' needs and traits of the housing etc. Through this, we made a schematic design for household units. Result: As a result, this study is a plan of making space, forms, and structure. The planned size is $38.4m^2$(L:12m, W:3.2m) except balcony, and indoor height is 2.5m. The space consists of entrance, bathroom, bedroom and living room with folding furniture system. Also there's a detailed floor plan of the ceiling, wall, and floor we drew up. The ceiling and wall consist of dampproof film, noncombustible board, fire proof urethane form, and color-designed sheet. The floor is composed of floor tile, cement mortar, light concrete(with heat coil), insulation, and dampproof film. Additionally, this study is a plan of interior dry wall with detail using modular construction method for work efficiency and quality improvement.

A Study on the Characteristics of Apartment Balcony after Legalization to Remodel the Balcony - Focused on Comparison of the Apartment Plans of Metropolitan Areas and Provincial Areas - (발코니 확장 합법화 이후 분양된 아파트 평면의 발코니 특성과 활용에 관한 연구 - 수도권과 군 이하지역의 아파트 평면비교를 중심으로 -)

  • Park, Kyoung-Ok;Lee, Sang-Un
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2008
  • The purpose of this study is to give some suggestions for the legal supplement of the regulation on the balcony expansion for the optimal use of apartment balcony. For the purpose, this study focused on the characteristics of spaces expanded to the balcony, in the plans supplied after the legalization of balcony expansion, comparing them by their location; the metropolitan area of Seoul Gyeonggi and the districts of the other areas. The 168 plans of apartments in the supplied by top 10 constructors in the metropolitan areas of Seoul and Gyeonggi, together with the 92 plans in the other smaller districts in 2006 to 2007 were analyzed with the tools of frequency and chi-square analysis. The result is as follows. (1) The region showed no difference in the plans of balcony; whereas the size, the position and access of the shelter explained some differences of balcony plan. (2) In wider plans, balconies were placed in all sides of plan-front, rear and side, and were remodeled to expand facing rooms. (3) The balcony expansion tended to increase the number of bays. (4) In almost cases, the living rooms were expanded to balcony. In smaller plans, the balconies were remodeled to supply supplementary kitchen space, splitting it from laundry. (5) The shelters were placed at the rear or side of plans, but the shelter facing room could be dangerous in case of fire. The balcony expansion, despite of legalization spirit to adopt diverse use of additional spaces for residents' needs, was only a tool for the space expansion. The amendment of the regulation is needed to accommodate these findings that the balconies should be identified by their function, that the front corridor-type balcony should be limited in length and magnitude, and that the shelter should be positioned with easy access.

  • PDF

Development of 2-ton thrust-level sub-scale calorimeter (추력 2톤급 축소형 칼로리미터 개발)

  • Cho, Won-Kook;Ryu, Chul-Sung;Chung, Yong-Hyun;Lee, Kwang-Jin;Kim, Seung-Han;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2005
  • A calorimeter of 2-ton thrust level rocket engine chamber has been developed to measure the wall heat flux. The liner of the chamber is made of copper-chromium alloy to maximize the heat transfer performance and structural strength. 1-D design code based on empirical correlations has been used for the prediction of the global thermal characteristics while 3-D CFD has been applied for the verification of local cooling performance. The predicted average wall heat flux at the throat is 43 $MW/m^{2}$ for the combustion chamber pressure of 53 bar. The chamber structure is confirmed to be safe at the pressure of 150 bar through 2-D stress analysis and measurement of the strain of the test species. Finally, the test of pressurizing the calorimeter chamber has been performed with water at the pressure of 150 bar in room temperature environment. No thermal damage has been detected after the hot-fire test in the test nozzle of same cooling performance with the developed calorimeter though the measured throat heat flux is higher than the design value by 10%.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Effects of Chemical Composition of Ca(OH)2 and Precursors on the Properties of Fast-Curing Geopolymers (Ca(OH)2와 전구체의 화학 조성이 고속경화 지오폴리머의 물성에 미치는 영향)

  • Ko, Hyunseok;Noh, Jung Young;Lim, Hyung Mi
    • Korean Journal of Materials Research
    • /
    • v.29 no.11
    • /
    • pp.690-696
    • /
    • 2019
  • Geopolymer is an alumina silicate-based ceramic material that has good heat-resistance and fire-resistance; it can be cured at room temperature, and thus its manufacturing process is simple. Geopolymer can be used as a reinforcement or floor finish for high-speed curing applications. In this manuscript, we investigate a high-speed curing geopolymer achieved by adding calcium to augment the curing rate. Metakaolin is used as the main raw material, and aqueous solutions of KOH and $K_2SiO_3$ are used as the activators. As a result of optimizing the high bending strength as a target factor for geopolymers with $SiO_2/Al_2O_3$ ratio of 4.1 ~ 4.8, the optimum ranges of the active agent are found to be $0.1{\leq}K_2O/SiO_2{\leq}0.4$ and $10{\leq}H_2O/K_2O{\leq}32.5$, and the optimum range of the curing accelerator is found to be $$0.82{\leq_-}Ca(OH)_2/Al_2O_3{\leq_-}2.87$$. The maximum flexural strength is found to be 1.35 MPa at $Ca(OH)_2/Al_2O_3=2.82$, $K_2O/SiO_2=0.3$, and $H_2O/K_2O=11.3$. The physical and thermal properties are analyzed to validate the applicability of these materials as industrial insulating parts or repairing finishing materials in construction.

Development of high-efficiency heating system using humidifying particles (가습 입자를 활용한 고효율 난방 시스템 개발)

  • Lee, Jeong-Won;Hong, Kyung-Bo
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.17-24
    • /
    • 2020
  • Products for heating indoors in low temperature and dry winter are largely divided into products using fossil fuels and products using electricity. The fossil fuels can warm the entire space by convection, but there is a high risk of fire and the frequent ventilation due to the increase in carbon monoxide and carbon dioxide. Heaters using electricity are mainly used because they are convenient to use and are cheap. However, these products can not efficiently warm the air because they use radiation energy. In other words, only the front part exposed to the heater is warm, and the rear part has no heating effect at all. Also, because it emits a large amount of light, fatigue of the eyes is very high. Another problem is that when using electric heaters, the room tends to be dry by high heat. Indoor humidity maintenance is a very important factor in the prevention and treatment of respiratory diseases. Especially, it is essential for health care for infants, bronchial organs and people with weak respiratory because humidity is low in winter. In this study, we conducted a study to develop a product that can improve heating efficiency while maintaining proper indoor humidity by combining heat energy and moisture particles. The concept of humidification and heating at the same time, moisture particles generated in the humidifier pass through the heater, include thermal energy, and the moisture particles with thermal energy are diffused into the space by forced convection, thereby warming the entire space. In addition, the heating time is shortened as the feeling temperature is increased with the high relative humidity, and this has the effect that the heating cost in winter is reduced.