• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.029 seconds

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Consideration of the Effect of Miscellaneous Factors on Frost Resistance of High Strength Concrete by Using the Factorial Design Method

  • Kwon Young-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.269-275
    • /
    • 2004
  • Factorial design method is applied to investigate the effects of various factors simultaneously rather than to conduct a series of single-factor experiment. As the results, frost resistance of the concrete specimens, in both W/C ratio of 0.28 and 0.35, was highly affected by the type of coarse aggregate that is, andesite produced more durable concrete than the limestone. Durability factor of the specimens, with W/C ratio of 0.28, which were demolded after I day and transferred to the curing room was higher than those demolded after 2 days. This stated the efficiency of the high early curing in high strength concrete.

A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol (TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구)

  • 문경록;이주열;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

Flame Retardancy of Zelkova Sarrata Treated with Ammonium Salts (암모늄염으로 처리된 느티나무의 난연성 시험)

  • Chung, Yeong-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.399-406
    • /
    • 2010
  • This study was performed to test the flame retardancy of zelkova sarrata-based materials by the treatment of ammonium salts. Zelkova sarrata plate was soaked by the treatment with three 20 wt% ammonium salt solutions consisting ammonium chloride (AMSL), monoammonium phosphate (MAPP), and diammonium phosphate (DAPP), respectively, at the room temperature. After the drying specimen treated with chemicals, combustion properties were examined by the cone calorimeter (ISO 5660-1). When the ammonium salts were used as the retardant for zelkova sarrata, the flame retardancy improved due to the treated ammonium salts in the virgin zelkova sarrata. However the specimen shows increasing CO over virgin zelkova sarrata and It is supposed that toxicities depend on extents. Also, the specimen with ammonium salts showed the higher total smoke release (TSR) than that of virgin plate. Of specimens treated with ammonium salts the ammonium chloride handled the test side was considered a improved inhibitory effect of combustion.

Strength properties of magnesium oxide matrix according to type of phosphate (인산염 종류에 따른 산화마그네슘 경화체의 강도 특성)

  • Lim, Jeong-Jun;Pyeon, Su-Jeong;Kim, Dae-Yeon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.79-80
    • /
    • 2018
  • Recently, the interest in remodeling of new and old buildings is increasing worldwide. As a result, the frequency of use of architectural adhesives has increased. Currently, adhesives used in buildings are made of organic materials in most cases, and epoxy resin adhesives are most widely used. However, epoxy resin adhesives contain formaldehyde and VOCs in the room during construction, which can cause sick house syndrome. In case of building fire, it may cause damage due to carbon monoxide generated from organic materials. It is urgent to study the problem of epoxy fill adhesive made of such organic materials. Therefore, the purpose of this study is to investigate the effect of the adhesion of epoxy resin adhesive, which is a problem of epoxy resin adhesive, which is an existing organic adhesive by using inorganic materials such as magnesia and phosphate, And the inorganic adhesive which does not emit the release amount as an inorganic material.

  • PDF

An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger (전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구)

  • Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table (조리대에 급기구를 가진 주방 레인지후드의 배기 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.

Studies on the determination of atmospheric sulfur dioxide and elimination of sulfur in kerosene by thiobacilli (미생물에 의한 공기의 SO$_{2}$ 오염방제에 관한 연구)

  • 이배함;이병조;이정근;정성구
    • Korean Journal of Microbiology
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 1969
  • The experiments attempted to basic studies on the atmospheric dioxide in Korea and on the elimination of sulfur in oil Thiobacilli in order to control of atmospheric sulfur dioxide. The results of experiments are following as : 1) Content of atmospheric sulfur dioxide in industrial zone which used kerosene for fuel was 0.092 ppm(average) and 0.16ppm(maximum). 2) Content of sulfur dioxide at room air which used briquet for stove fire was 0.44ppm (average) adn 0.50 pp,(maximum). 3) Thirteen strains of thiobacilli were isolated from Korean soil and sewage and they were identified with T. thiooxidans (5strains), T. thioparus(3strains), T.ferrooxidans 3 man's observation and the description in Bergey's manual. 4) Two promising strains, one of T. thiooxidans and one of T. ferooxidans. were selected for elimieation of in kerosene.

  • PDF

A Study on Characteristics of Interior design materials in Leisure Boats & Yachts (레저보트${\cdot}$요트의 인테리어재료 특징에 관한 연구)

  • Byun Lyang-Soun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.1 s.54
    • /
    • pp.158-165
    • /
    • 2006
  • The space of leisure boats & yachts is formed by interior design elements and shapes are formed by combination of those elements. By means of configuration of the design elements, space is made in a ship and patterns in an inside space are made through production. These space can be categorized as (1) cabin(common cabin, staterooms, one-cabin), (2) salon, (3) galleys & dinette, (4) heads(showers, toilets, bidets, sinks), (5) cockpit, (6) wheelhouses, navigation stations, (7) fore peaks, (8) engine room, (9) deck etc. Interior materials are classified into (1) walls(bulkheads & lining wall), (2) floors(sole), (3) ceilings(overheads), (4) doors & windows, (5) furniture, (6) lightings and (7) Hardware & decoration in large, medium and small sizes, which constitute interior design elements of a leisure boat & yacht. The materials used in leisure boats & yachts have properties of lightweight, noise and vibration resistance, fire & flame retardant, stability, strengths, lifespan, appearance and special operation in construction.