• 제목/요약/키워드: Room fire

검색결과 528건 처리시간 0.024초

A Study on Smoke Movement in Room Fires with Various Pool Fire Location

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1485-1496
    • /
    • 2002
  • In order to investigate the fire-induced smoke movement in a three-dimensional room with an open door, numerical and experimental study was performed. The center, wall, and corner fire plumes for various sized fires were studied experimentally in a rectangular pool fire using methanol as a fuel. The numerical results from a self-developed SMEP (Smoke Movement Estimating Program) field model were compared with experimental results obtained in this and from literature. Comparisons of SMEP and experimental results have shown reasonable agreement. As the fire strength became larger for the center fires, the air mass flow rate in the door, average hot layer temperature, flame angle and mean flame height were observed to increase but the doorway-neutral-planeheight and the steady-state time were observed to decrease. Also as the wall effect became larger in room fires, the hot layer temperature, mean flame height, doorway-neutral-planeheight and steady-state time were observed to increase. In the egress point of view considering the smoke filling time and the early spread of plume in the room space, the results of the center fire appeared to be more dangerous as compared with the wall and the corner fire. Thus it is necessary to consider the wall effect as an important factor in designing efficient fire protection systems.

화재 시뮬레이션을 이용한 아파트 화재 위험성 분석 (Hazard analysis by fire simulation in an apartment fire)

  • 김태권;차우섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-388
    • /
    • 2014
  • 본 연구는 CFAST를 이용하여 아파트 화재가 발생하였을 때 인체에 끼치는 위험요소를 예측한다. CFAST 소프트웨어는 National Institute of Standards Technology 산하기관인 Building and Fire Research Lab에서 개발되어진 모델이다. 본 해석 시나리오는 아파트 화재 재현 실험결과에 의해 검증되었다. 해석결과를 요약하면, 침실뿐만 아니라 거실과 작은방의 상황도 실험 데이터와 정성적으로 같은 경향을 보인다. 화재 당시 거실과 작은방에 사람이 있었다면 산소와 이산화탄소의 농도로 인하여 어지러움을 호소하거나 심하게는 구토, 마비 같은 증상이 발생되었을 것으로 예측되었다.

국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션 (Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant)

  • 강대일;김길유;장승철;유성연
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

교육시설 화재위험성 평가를 위한 기초조사에 관한 연구 (A Study on the Basic Investigation for the Fire Risk Assessment of Education Facilities)

  • 이성일;함은구
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.351-364
    • /
    • 2021
  • 연구목적: 교육시설 화재위험성 평가를 위한 기초 데이터 확보를 위하여 화재하중 분석하였다. 사전조사로 화재하중을 산정하기 위해 학교시설의 화재하중과 관련된 기초자료를 수집하였다. 연구방법: 기초자료는 화재하중의 정의 및 종류, 화재하중 산정을 위한 연소열 데이터 화재하중에 대한 선행연구를 통하여 진행하였고 화재하중 산출시 구획실에 존재하는 가연물 중량에 해당 연소열을 곱하여 산정하였다. 연구결과: A 초등학교의 고정가연물은 교실, 음악실, 교무실은 정서나 안전을 고려하여 바닥이 주로 목재로 이루어져 있었으며, 나머지 구획실은 석재로 이루어졌다. 천장과 벽은 석고보드, 콘크리트로 되어있어 가연물에 속하지 않았다. 각 실별로 대표적인 적재가연물은 교실은 책상, 의자, 사물함 등으로 나타났으며 과학실은 실험기구함, 실험도구함이 주를 이루어었으며 도서실은 책과 서가, 열람기구 등이 큰 비중을 차지하였다. 결론: A 초등학교의 적재가연물에 따른 적재화재하중은 도서실, 컴퓨터실, 영어학습실, 교무실, 일반교실, 과학관, 음악실의 순으로 나타났다.

건축물의 피난계획에 관한 기초적 연구 (A Basic Study on the Evacuation Plans of Buildings)

  • 고치원
    • 한국화재소방학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-6
    • /
    • 2000
  • With the "Fire Protection Building Plan" of the Building Center of Japan as a sample, actual evacuation plans used for large scaled and multi-storied buildings are analyzed. Sufficient number of samples were classified into 6 categories. For room evacuation, time to pass through the exit was the most critical point for larger spaces and movement time in the room was the key for smaller evacuation object zone and less number of evacuees. Seen from the location of fire breakout point, it was witnessed that the numbers of crowding at the exits of the fire escape staircase are serious for floor level evacuation. For vertical traffic line, it was actually proved that time to fire escaping floor is problem of higher buildings. It was also proved that special evacuation methods are in practical use in many buildings in japan.

  • PDF

반도체 제조공정의 연기유동에 관한 연구 (A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process)

  • 한수진;강경식
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석 (CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process)

  • 천광수;이진석;박명남
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.35-44
    • /
    • 2021
  • 반도체 공정 중 PR (Photo Resist) 공정은 여러 인화성 물질을 혼합하여 사용하는 공정으로, 공정 장비가 Clean Room 내 설치되어 인화성 물질이 누출되는 경우 질식, 화재, 폭발 사고로 이어질 위험성이 크므로, 물질 누출시 발생할 수 있는 사고에 대한 영향을 분석하고, 작업자들의 안전을 보장할 수 있는지 평가하는 것이 필요하다. 본 연구는 FLACS CFD - Fire Module을 이용하여 10개의 누출, 화재 시나리오에 대한 CFD Simulation을 통해 Clean Room 내부 가상으로 설정한 Monitor Point에서의 복사열 및 온도 변화 값을 확인하였다. Clean Room 내부에서 발생한 화재는 층간 구조물에 높은 복사열을 전달하지만, 그 범위가 상당히 제한적이며, 단일 화재 사고로 인해 붕괴될 가능성이 희박하다. 화재 사고로 인해 탈출구로 이어지는 2 곳의 계단이 동시에 높은 복사열에 노출되는 시나리오는 없어, 화재 발생시 작업자가 탈출 가능하였다. 또한 복사열 및 온도 상승의 수준은 아래층으로 이동하면서 급격하게 낮아지는 것을 확인하였으며, API 520의 기준에 따라 작업자가 30초 동안 버틸 수 있는 복사열인 6.31 kW/m2에 노출된 작업자도 화재가 발생한 Clean Room 내부에서 충분히 탈출할 수 있음을 확인하였다.

특수 방호공간에서 가상화재의 발생으로 인한 화재거동에 관한 수치적 연구 (A Numerical Study on the Fire Behavior Phenomena in a Special Fire Protection Compartment)

  • 김태국;손봉세
    • 한국방재학회 논문집
    • /
    • 제1권1호
    • /
    • pp.157-163
    • /
    • 2001
  • 본 연구의 목적은 청정실 내부에서 가상의 화재가 발생할 경우 화재 확산 및 연기의 전파 현상을 예측하기 위하여 실시하였다. 청정실 내의 화재로 인한 온도 및 속도분포의 해석은 유한체적법을 이용한 수치적 방법으로 해석하였으며 난류유동장의 계산은 표준 $k-{\varepsilon}$ 모델을 적용하여 실시하였다. 본 연구 결과는 화재발생 후 150초가 지난 후에는 화재가 완전히 성장한 것으로 나타났으며 이 경우 환기장치는 화재가 완전히 성장한 후에 정지하는 것으로 가정하였다. 연기의 질량분율은 온도 분포와 거의 유사한 것으로 나타났다. 따라서 청정실에서 화재가 발생할 경우 화재 성장이 60초 내에 전공간의 $20{\sim}30%$까지 확산되므로 내부에 있는 사람은 30초 이내에 대피하는 것이 바람직하다.

  • PDF

DISCRIMINATION OF IN-ORDINAL STATE IN ROOM TEMPERATURE BASED ON STATISTICAL ANALYSIS

  • Takanashi, Ken-ichi;Daisuke Kozeki;Yoshiyuki Matsubara
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.484-491
    • /
    • 1997
  • In this paper, an approach to determine the in-ordinal condition of a room, which is based on multi variable analysis, is proposed. According to this approach, the distance of a state from the ordinal condition is thought to be evaluated by the Mahalanobis' distance. The temperature changes of a room were measured and their statistical characteristics such as distribution type, the mean value and the standard deviation are studied. The applicability of the method for the fire detection is also investigated.

  • PDF

보일러실 화재.폭발사고 경감방안에 관한 연구 (A Study on the mitigation method of explosion and fire accidents in the Boiler room)

  • 손은수;백명기;송재수;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.405-409
    • /
    • 2007
  • This paper focused on the way of prevention of disaster in the accident of explosion when the fire broke out in the boiler room where installed the basement of the building, and showed the effective ways for sustaining people and property safely in the view of problems and improvement of the law and safety awareness of people.

  • PDF