• 제목/요약/키워드: Room air

검색결과 1,752건 처리시간 0.028초

Ti-6Al-4V의 피로균열성장거동에 관한 연구(I) (A Study on the Fatigue Crack Growth Behavior in Ti-6Al-4V Alloy(I))

  • 우흥식;한지원
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.52-57
    • /
    • 2001
  • Fatigue crack growth behaviour of Ti-6A-4V alloy is investigated in air and salt solution environment at room temperature and $200^{\circ}C$. Fatigue crack growth rate is blown to be fast for the formation of corrosive product in hot salt environment. For the effect on corrosion fatigue crack growth behaviour of region II. fatigue crack growth rate in atmosphere had a little gap to both case, $200^{\circ}C$ and room temperature. However, it showed very fast tendency in salt corrosive atmosphere, and it was remarkably accelerated in $200^{\circ}C$ temperature salt environment. When $\Delta$K was approximately 30MPa(equation omitted), fatigue crack growth rate had a little difference between at room temperature and at $200^{\circ}C$ high temperature, however in case of salt corrosive environment the room temperature was 3.5 times Inter and $200^{\circ}C$ high temperature for 16 times than air environment respectively.

  • PDF

파노라마-PIV를 이용한 실내기류 해석 (Analysis of Airflows in a Room with Panoramic PIV)

  • 황태규;도덕희
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1154-1160
    • /
    • 2005
  • A panoramic-PIV system has been constructed for the analysis of the airflows in a room. Smoke is used as seeding particles and are visualized by a pulsed laser (Nd-Yag, 120 mJ). Panoramic images have been obtained by an image composition process using the two images obtained by the two cameras $(1k\times1k)$ that are viewing the wide measurement areas. Velocity vector fields have been obtained by the grey-level cross-correlation PIV method. Three room models $(L{\times}W{\times}H[mm^3],\;500\times500\times250,\;350\times350\times175,\;250\times250\times125)$ have been tested. The experimental results have proven that the constructed panoramic-PIV system can be used as a useful tool for analyzing the airflow characteristics in the room models.

CLEAN ROOM

  • 양희찬
    • 대한설비공학회지:설비저널
    • /
    • 제8권1호
    • /
    • pp.29-42
    • /
    • 1979
  • PDF

IMPROVING THE SPEECH INTELLIGIBILITY IN AN AIR-TRFFIC CONTROL ROOM

  • Pavuza, Franz G.;Beszedics, Geza W.;Pichler, Heinrich
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.912-918
    • /
    • 1994
  • Poor speech intelligibility in an air traffic control room is frequently a result of many, quite different causes and occasionally leads to complaints of the controller personnel. The paper describes a sequence of successful tasks performed in a local control room. The initial measurements included an investigation of the background noise (caused by fans, air condition, computer and radar equipment) and performance checks of the electronic audio and communication equipment with respect to the audio transmission behavior. The spectral composition of the noise as well as the characteristics of the audio communication path between the controllers and the pilots(which showed a loss of spectral information in the audio band due to built-in notch filters for the suppression of control tones) required adaptations of the amplitude behavior of the amplifiers through user adjustable tone controls. The radar console fans, which contributed significantly to the overall noise floor of the room, underwent a substantial reconstruction by replacing the tight mounting with an elastic double suspension, reducing the noise level by 50%. Finally, a possible source of untimely fatigue of the controllers during their working hours has been found in strong spectral components of the noise above the audio band, radiated by numerous video monitors in the control through vibrating components excited by the line frequency of the video signal.

  • PDF

실외온도 변화에 따른 R410A 적용 에어콘 시스템의 성능 (Performance of a room air conditioner using R410A according to the variation of outdoor temperature)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.537-541
    • /
    • 1999
  • The system performance of a room air conditioner using R410A was experimentally evaluated and compared with that of R22 system. The results indicated that the cooling EER(energy efficiency ratio) of R410A was 1% higher than that of R22 at the outdoor temperature of $35^{\circ}C$. As outdoor temperature increases above $35^{\circ}C$ ambient, EER of the R410A system decreased more substantially compared with R22 system. R410A showed higher compressor discharge temperature than that of R22 system at the outdoor temperature of higher than $50^{\circ}C$.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF