A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.

A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center (데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구)

  • Chang, Hyun Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

Numerical Analysis of Thermal Environments and Comfort for Local Air Conditioning System (수치해석에 의한 국부냉방시스템의 온열환경 및 쾌적성 분석)

  • 엄태인;경남호;신기식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.318-328
    • /
    • 2003
  • Numerical simulation using computational fluid dynamics (CFD) is performed to calculate the velocities and temperature profiles of air in adjacent to a worker within the individual local air conditioning system. The calculation domain is the space of ㄴ between walls and a worker in the climate room. The fresh air is supplied from the three different inlets located on the right, left and center wall in the climate room. In this study, the calculated data of velocities and temperature profiles of air in the nearest the skin of a worker are used to calculate the PMV (Predicted Mean Vote) for evaluation of thermal comfort of a worker in the local air conditioning system. Because the data of veto-cities temperature profiles of air in adjacent to a worker and the PMV of a worker are the design parameters of the local air conditioning system. The results of calculation show that the fresh air velocity and injection position are closely related to the PMV value. In individual air condition system of ㄴ, the appropriate PMV are obtained when the fresh air velocity and position are 1.0 m/s, throat of a worker and are 1.5 m/s, head of a worker, respectively. The method of numerical calculation is effective to obtain the optimum velocity and position of the fresh air for optimum the PMV and energy saving in individual local air conditioning system.

A Study on Improvement According to Korea and China Evacuation Laws in Office Building (오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

NUMERICAL STUDY ON PERFORMANCE ASSESSMENT AND INSTALLATION CONDITIONS OF AN AUTOMOTIVE AIR CLEANER (자동차용 공기청정기의 성능 평가 및 설치 조건 도출을 위한 수치해석적 연구)

  • Lee, Y.H.;Seo, J.W.;Park, J.H.;Choi, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.263-270
    • /
    • 2010
  • In this study, an air cleaner is considered to improve comfort, safety, and health of automobile passengers. The performance and installation conditions of the air cleaner have been studied to investigate their effects on the air quality in the cabin room using numerical analysis. A five-passenger sedan and a seven-passenger minivan that have comparatively large indoor volume have been considered. The distributions of the local mean age and the volume averaged age of indoor air are calculated according to the variation of the placement and the air flow of the air cleaner. In addition, a decrease of contamination concentration, especially VOCs(volatile organic compounds), by the air cleaner is numerically analyzed with time-accurate unsteady calculation to quantify the effect of the air cleaner on the indoor air quality. As a result, the effective installation and operation conditions of the air cleaner for the automobile cabin room could be suggested.

  • PDF

Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province (제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가)

  • 김봉애
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.

  • PDF

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

A Study on the Heat Pump-Latent Heat Storage Type (열펌프-잠열축열 온돌 시스템 연구)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

The Effective Heating Control Method of the Radiant Floor Heating System (바닥복사 난방공간의 효율적인 난방제어방법)

  • Cho, S.H.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

An Experimental Study on the Dehumidification Characteristics and the Effectiveness for Operating Conditions of a Desiccant Rotor (운전조건에 따른 제습로터의 제습특성과 유용도에 관한 실험적 연구)

  • Kang, Byung-Ha;Lee, Jin-Joo;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • An experimental study has been carried out to investigate the dehumidification characteristics for several operating conditions of a compact desiccant rotor. This problem is of particular interest in the design of a desiccant type of dehumidifier. Room temperature, room humidity, regeneration temperature, revolution speed and frontal air velocity of desiccant rotor are varied as operating conditions. The results obtained indicate that dehumidification rate is increased with an increase in the room humidity while dehumidification effectiveness is not changed much. It is also found that the optimal rotor speed and optimal regeneration temperature exist for maximum dehumidification rate and dehumidification effectiveness.