• 제목/요약/키워드: Room Sensor

검색결과 406건 처리시간 0.039초

도시철도 실시간 모니터링 시스템 적용 사례 (Application of 5678SMRT Real-time Monitoring system)

  • 윤재관;박종헌;김기춘
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.737-747
    • /
    • 2011
  • 5678SMRT has installed various sensor for operating conditions(field of electric, facilities, signal, communication equipment and track) and environment of Every Function Room for remotely detecting and monitoring. Installed sound sensor for analyzed after remotely heard the noise of every equipment at Every Function Room and temperature sensor for check the temperature condition of Every Function Room. Additional installed voltage sensor in signal equipment room for monitoring RF track-circuit's voltage condition. Installed displacement sensor at The Chungdam bridge's railway for measuring and monitoring track displacement caused by temperature change and Pan/Tilt camera at sub-station and drainage for remotely field monitoring. Installed sensor for each equipment's operating condition and failure at Every Function Room then periodic check of workforce turned to around-the-clock surveillance by sensor therefore improvement of operating equipment. SMRT is lots of prevent a failure by Immediately detect of precondition of equipment failure by analyzed the sensor data. If the occurrence of an failure, become detected Immediately so possibility correct diagnosis and order by remotely field check by installed camera and sound sensor at field.

  • PDF

센서 네트워크 기반 강의실 제어시스템 구현 (Implementation of A Lecture Room Control System Based on a Sensor Network)

  • 빈기철;이종민;권오준
    • 한국멀티미디어학회논문지
    • /
    • 제12권3호
    • /
    • pp.436-444
    • /
    • 2009
  • 최근 들어 센서 네트워크에 대한 관심이 증가됨에 따라서 다양한 분야에서 이를 활용한 연구가 이루어지고 있다. 본 논문에서는 센서 네트워크 기반 강의실 제어 시스템을 제안하고 구현한다. 강사의 강의 이력 정보를 센서 네트워크를 통하여 수집하고, 이 정보를 활용하여 강사가 강의실에 들어갈 때 강의실 내 PC, 빔 프로젝터, 전등 등을 강의에 적합한 형태로 제어해 주면 효과적인 강의 진행이 가능하다. 본 논문에서 제안한 강의실 제어 시스템이 효과적으로 동작할 수 있도록 센서 네트워크를 구축하고 성능 실험을 한다. 이를 통하여 강의실에 설치한 센서 노드의 메시지 발생 주기와, 센서 노드 간 통신이 원활하게 이루어질 수 있도록 강의실 내 배치된 센서 노드의 수를 최적화할 수 있는 값을 구하였다.

  • PDF

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

Design of Semiconducting Gas Sensors for Room-Temperature Operation

  • Song, Young Geun;Kim, Gwang Su;Ju, Byeong-Kwon;Kang, Chong-Yun
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2020
  • Gas sensors that operate at room temperature have been extensively studied because of sensor stability, lift time, and power consumption. To design effective room-temperature gas sensors, various nanostructures, such as nanoparticles, nanotubes, nanodomes, or nanofibers, are utilized because of their large-surface-to-volume ratio and unique surface properties. In addition, two-dimensional materials, including MoS2, SnS2, WS2, and MoSe, and ultraviolet-activated methods have been studied to develop ideal room-temperature gas sensors. Herein, a brief overview of state-of-the-art research on room-temperature gas sensors and their sensing properties, including nanostructured materials, two-dimensional materials, the ultraviolet-activated method, and ionic-activated gas sensors, is provided.

상온감지 가능한 탄소나노튜브 방적사 기반의 수소 감지 센서 (Room Temperature Hydrogen Gas Sensor Based on Carbon Nanotube Yarn)

  • 김재건;이준엽;공성호;정대웅
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.132-136
    • /
    • 2018
  • We report the development of a room-temperature hydrogen ($H_2$) gas sensor based on carbon nanotubes (CNT) yarn. To detect $H_2$ gas in room temperature, a highly ordered CNT yarn was placed on a substrate from a spin-capable CNT forest, followed by the deposition of a platinum (Pt) layer on surface of the CNT yarn. To examine the effect of the Pt-layer on the response of the CNT sensor, a comparative sensing performance was characterized on both the Pt deposited and non-deposited CNT yarn at room temperature. The Pt-CNT yarn yielded high response, whereas the non-deposited CNT yarn showed negligible response for $H_2$ detection at room temperature. Pt is a reliable and efficient catalyst that can substantially improve the detection of $H_2$ gas by chemical sensitization via a "spillover" effect. It can be efficiently utilized to increase the sensitivity and selectivity as well as to obtain fast response and recovery times.

An ITO/Au/ITO Thin Film Gas Sensor for Methanol Detection at Room Temperature

  • Jeong, Cheol-Woo;Shin, Chang-Ho;Kim, Dae-Il;Chae, Joo-Hyun;Kim, Yu-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권2호
    • /
    • pp.77-80
    • /
    • 2010
  • Indium tin oxide (ITO) films with a 5 nm thick Au interlayer were prepared on glass substrates. The effects of the Au interlayer on the gas sensitivity for detecting methanol vapors were investigated at room temperature. The conductivity of the film sensor increased upon exposure to methanol vapor and the sensitivity also increased proportionally with the methanol vapor concentration. In terms of the sensitivity measurements, the ITO film sensor with an Au interlayer shows a higher sensitivity than that of the conventional ITO film sensor. This approach is promising in gaining improvement in the performance of ITO gas sensors used for the detection of methanol vapor at room temperature.

팔라듐/탄소나노튜브 버키페이퍼를 이용한 상온감지 수소가스 센서 (Room Temperature Hydrogen Gas Sensor using Pd/Carbon Nanotubes Buckypaper)

  • 한마음;김재건;김영삼;정동건;공성호;정대웅
    • 센서학회지
    • /
    • 제29권6호
    • /
    • pp.394-398
    • /
    • 2020
  • In this paper, we report the sensing performance of H2 gas sensors composed of Pd/carbon nanotube (CNT) buckypaper at room temperature. The CNT buckypaper was made using a simple filtration process and subsequently deposited with Pd as the sensing material. The sensitivity of the sensor increased with respect to the gas concentration. To investigate the effect of Pd thickness, Pd layers of different thickness were deposited on the buckypaper, and the response of the sensor was evaluated. The proposed sensor exhibits excellent sensing properties with optimized Pd thickness at room temperature (25℃). Pd nanoparticles significantly impact the sensitivity and selectivity of the sensor because of the spillover effect. In addition, the sensor is highly suitable for bendable and wearable devices owing to its structural flexibility.

저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템 (Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network)

  • 이승철;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.397-400
    • /
    • 2007
  • 본 연구에서는 소형, 저전력 센서와 센서 인터페이스를 구현하여 빌딩내의 실내 공조시스템과 함께 연동하고자 하였다. 빌딩 내 공조시스템은 저비용인 저전력 무선센서 노드간의 네트워크를 형성하여 각 룸마다 오염농도를 분석하여 룸의 오염 상태를 확인 한 후 실내 공조시스템에 있는 팬을 자동으로 조절해서 최적의 환경을 조성할 수 있게 하였다. 또한 GUI 인터페이스를 통해 각 룸의 있는 센서노드의 배터리 상태를 확인할 수 있는 것은 물론 모니터링이 필요한 가스의 농도와 온도 등을 확인 할 수도 있었다. 본 논문에서는 IEEE 802.15.4와 Zigbee를 지원하는 근거리 통신망을 갖는 저전력 무선센서 노드를 이용하여 무선센서 네트워크를 형성하기 위해 Ad-hoc 기능을 갖는 Simple forwarding routing을 구현하였다. 그리고 가스센서의 전력소모를 줄이기 위해서 전기화학적으로 환원 또는 산화하여 외부회로에 흐르는 전류를 측정하는 저전력 전기화학식 가스센서를 사용하였으며, 가스센서 인터페이스를 저전력으로 동작하도록 설계하였다.

  • PDF

Design of multi-sensor system for comprehensive indoor air quality monitoring

  • TaeHeon Kim;SungYeup Kim;Yoosin Kim;Min Hong
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권7호
    • /
    • pp.149-158
    • /
    • 2024
  • 본 연구는 다양한 실내 환경에서 공기질을 모니터링 할 수 있는 다중 센서 시스템인 AirDeep-Room을 설계 및 개발하였다. 이 시스템은 CO2, TVOC, 미세먼지, 온도, 습도 등을 실시간으로 측정하며, 멀티 센서를 통해 다양한 환경에서의 공기질 변화를 분석할 수 있는 장점을 제공한다. AirDeep-Room 시스템은 low data 형식으로 데이터를 실시간으로 확인할 수 있으며, 실내 환경에서의 공기질에 대한 분석을 진행하였다. 설계한 센서 시스템을 상이한 환경인 서버실과 강의실에 설치해 실험을 수행한 결과, 서버실에서의 온도와 습도는 -0.24의 음의 상관관계를, 강의실에서는 0.43의 양의 상관관계를 보였다. 강의실에서의 실험 결과는 학생 수와 CO2 및 TVOC 농도가 r=0.69로 높은 상관관계를 보였다. 이는 학생 수가 실내 공기질 변화에 중요한 영향을 미칠 수 있음을 보여준다. 이러한 결과는 AirDeep-Room 시스템이 다양한 환경에서 공기질을 보다 효과적으로 관리할 수 있는 기반을 제공하며, 인구 밀도가 높은 공간에서 공기질 개선을 위한 중요한 역할을 할 수 있을 것으로 기대된다.