• 제목/요약/키워드: Roofs

검색결과 328건 처리시간 0.02초

현상적 투명성의 개념을 통한 문루건축 공간의 상호 연계성 연구 - 사찰.서원 중층문루 건축 개체간의 연계성을 중심으로 - (A Study on the Characteristics of Phenomenal Transparency of the spatial Interrelation in the Architecture of the Moonru Multi roofs - Focused on Interrelation between Seo Won gate-house and temple gate-house in the Architecture entities of the Moonru Multi roofs -)

  • 류인혜;박진아;안은희;최경란
    • 한국실내디자인학회논문집
    • /
    • 제20권4호
    • /
    • pp.74-82
    • /
    • 2011
  • All the phenomena and subjects of nature and society are within correlation interconnection, and they are inseparably connected one another. The elements of this interaction can be found out through the concept of transparency in the space composition of Korean traditional architecture. This study is focusing on the access space, in other words, a gate-house that is a buffer zone playing a process role up to the main space among successive spaces. It was chosen to be the subject of the study since it strengthens convergence into the main building and with the effect connecting spaces, it could show well the spatial possibility of transparency. Besides, the subject of the study is limited to the Moonru Multi roofs that improves the functionality of spaces between gate-houses, and it is intended to progress contents by comparative analysis of two kinds such as Seo Won gate-house and temple gate-house. Korean traditional architecture places emphasis on harmony within the whole spaces. There are intimate relations between surrounding environment, external spaces and internal spaces, and it is important understand the spatial relations according to the shape appearing through interactions of parts in the whole spaces. In conclusion, the Moonru Multi roofs is analyzed with the method of extracting the concept that is contained in the frame of analysis and through ecological views through a visible and structural method. It can be understood what kinds of method for communication were used for ancestors to recognize and use spaces with the deduced concept through the analysis of the Moonru Multi roofs with different character.

Numerical prediction of the proximity effects on wind loads of low-rise buildings with cylindrical roofs

  • Deepak Sharma;Shilpa Pal;Ritu Raj
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.277-292
    • /
    • 2023
  • Low-rise structures are generally immersed within the roughness layer of the atmospheric boundary layer flows and represent the largest class of the structures for which wind loads for design are being obtained from the wind standards codes of distinct nations. For low-rise buildings, wind loads are one of the decisive loads when designing a roof. For the case of cylindrical roof structures, the information related to wind pressure coefficient is limited to a single span only. In contrast, for multi-span roofs, the information is not available. In this research, the numerical simulation has been done using ANSYS CFX to determine wind pressure distribution on the roof of low-rise cylindrical structures arranged in rectangular plan with variable spacing in accordance with building width (B=0.2 m) i.e., zero, 0.5B, B, 1.5B and 2B subjected to different wind incidence angles varying from 0° to 90° having the interval of 15°. The wind pressure (P) and pressure coefficients (Cpe) are varying with respect to wind incidence angle and variable spacing. The results of present numerical investigation or wind induced pressure are presented in the form of pressure contours generated by Ansys CFD Post for isolated as well as variable spacing model of cylindrical roofs. It was noted that the effect of wind shielding was reducing on the roofs by increasing spacing between the buildings. The variation pf Coefficient of wind pressure (Cpe) for all the roofs have been presented individually in the form of graphs with respect to angle of attacks of wind (AoA) and variable spacing. The critical outcomes of the present study will be so much beneficial to structural design engineers during the analysis and designing of low-rise buildings with cylindrical roofs in an isolated as well as group formation.

Modeling the Effects of Low Impact Development on Runoff and Pollutant Loads from an Apartment Complex

  • Jeon, Ji-Hong;Lim, Kyoung-Jae;Choi, Dong-Hyuk;Kim, Tae-Dong
    • Environmental Engineering Research
    • /
    • 제15권3호
    • /
    • pp.167-172
    • /
    • 2010
  • The effects of low impact development (LID) techniques, such as green roofs and porous pavements, on the runoff and pollutant load from an apartment complex were simulated using the Site Evaluation Tool (SET). The study site was the Olympic Village, a preexisting apartment complex in Seoul, South Korea, which has a high percentage of impervious surfaces (approximately 72% of the total area). Using the SET, the effects of replacing parking lots, sidewalks and driveways (37.5% of the total area) having porous pavements and rooftops (14.5% of the total area) with green roofs were simulated. The simulation results indicated that LID techniques reduced the surface runoff, and peak flow and pollutant load, and increased the evapotranspiration and soil infiltration of precipitation. Per unit area, the green roofs were better than the porous pavements at reducing the surface runoff and pollutant loads, while the porous pavements were better than green roofs at enhancing the infiltration to soil. This study showed that LID methods can be useful for urban stormwater management and that the SET is a useful tool for evaluating the effects of LID on urban hydrology and pollutant loads from various land covers.

하중제한이 기존건물의 옥상조경계획에 미치는 영향 (Influence of Load Limitation on the Roofspace Planning of Existing Buildings)

    • 한국조경학회지
    • /
    • 제26권2호
    • /
    • pp.166-180
    • /
    • 1998
  • In a city where the greenery always lacks landscaping roofs of existing buildings offers a way to solve the problem. But the most serious problem that poses is the matter of load limit. At present most existing buildings have the loading capacity of 200 kg/$m^2$ or less on their roofs. If the natural soil is used the loading capacity is easily surpassed because it simply is too heavy. To alleviate this problem it is realized to introduce the light weight artificial soil. The specific gravity of light soil is 0.65 whereas the natural soil is 1.8 when wet. It is three times lighter than the natural soil, thus eases the burden to the roof. The next problem to be confronted is the plant species to plant. It is possible to plant trees but they soon outgrow the loading capacity by weighing 8 times heavier in 10 years. Therefore shrubs and perennials are suggested to be planted because they don't weigh much even when they reach the mature height. The last problem is the stress put on roofs by the weight of the users. By some unexpected event the crowd gathered on a weak roof can cause the structural damage or even the collapse of the roof. The avoid the possibility of collapse a plaza or big pocket should not be designed in a roof garden because they hold crowd. By following the suggested means the old roofs of existing buildings can turn into the urban oases in the sky.

  • PDF

풍동 실험을 통한 타원형 개폐식 돔 지붕의 외장재용 풍압 계수 분석 (Analysis of External Peak Pressure Coefficients for Cladding in Elliptical Retractable Dome Roof by Wind Tunnel Test)

  • 이종호;김용철;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.49-59
    • /
    • 2020
  • This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.

Review of international wind codes and recent research on mono-slope canopy roof

  • Pratap, Ajay;Rani, Neelam
    • Wind and Structures
    • /
    • 제34권4호
    • /
    • pp.371-383
    • /
    • 2022
  • Buildings with mono-sloped roofs are used for different purposes like at railway platforms, restaurants, industrial buildings, etc. Between two types of mono-slope roofs, clad and unclad, unclad canopy types are more vulnerable to wind load as wind produces pressure on both upper and lower surfaces of the roof, resulting in uplifting of the roof surface. This paper discusses the provisions of wind loads in different codes and standards for Low-rise buildings. Further, the pressure coefficients on mono-slope canopy roof available in wind code and standards are compared. Previous experimental studies for mono-slope canopy roof along with the recent wind tunnel testing carried out at Indian Institute of Technology, Roorkee is briefly discussed and compared with the available wind codes. From the study it can further be asserted that the information available related to staging or blocking under the mono-slope canopy roofs is limited. This paper is an attempt to put together the available information in different wind codes/standards and the research works carried out by different researchers, along with shedding some light on the future scopes of research on mono-slope canopy roofs.

공장과 주택 슬레이트지붕의 석면 노출특성 비교 (Comparison on the Releasing Characteristics of Asbestos Fiber from Plant Slate Roof and House Slate Roof)

  • 정재원;유은철;이상준;박근태
    • 한국환경과학회지
    • /
    • 제24권7호
    • /
    • pp.927-937
    • /
    • 2015
  • This study was performed to identify and quantify the asbestos fibers released from two types of asbestos-cement slate roofs. One is a plant roof installed in 1987 which contained 15% chrysotile, and the other is a residential roof installed before 1983 which contained 12% chrysotile. The concentrations of asbestos fibers in air surrounding asbestos-cement slate roofs and in the falling water harvested from the same roofs on rainy days ranged from 0.0012 to 0.0018 f/mL and from 1,764 f/L to 10,584 f/L, respectively. The concentration of inorganic fibers in the soil around asbestos-cement slate roofs was from 217 to 348 f/g. With the above results, the excess lifetime cancer risk (ELCR) for the risk assessment of the asbestos fibers released from asbestos-cement slate based on US EPA IRIS (Integrated risk information system) model is within 5.5E-06 ~ 6.5E-06 levels which indicates that the levels do not exceed "the acceptable risk(1.0E-05)" recommended by WHO. The asbestos concentration in air, drained rainfall and soil around the plant slate roof was higher than that around residential slate roof, but the excess lifetime cancer risk (ELCR) from residential slate was higher than that from plant slate. This suggested that the enclose and encapsulation of residential roofs have priority in removal policy to minimize the exposure risk.

빗물활용 옥상녹화 녹색기술 개발을 위한 친수성 중합체의 효용성 (Utility of Hydrophilic Polymer for Green Technology Development in Green Roofs Using Rainwater)

  • 주진희;양지;윤용한
    • 한국환경과학회지
    • /
    • 제21권12호
    • /
    • pp.1469-1476
    • /
    • 2012
  • Hydrophilic polymer is suitable as soil conditioners for green roofs that use rainwater, due to promotion of water retention capacity as well as enhancement of the water absorbing capacity. The objective of the present study was to investigate the effects of different levels of hydrophilic polymer concentrations (0, 0.1, 0.2, 0.4, 0.8% w/w) on the water holding capacity and growth response of 6 species in soils amended with hydrophilic polymer in 5 cm of soil thickness on green roofs. The results showed that the water holding capacity of the amended soil improved with increasing amount of applied polymer. The application of 0.8% w/w of the polymer increased the soil moisture by 87% compared to the control, and decreased slowly in green roofs during an arid period. The growth of Sedum spurium 'Dragon's blood' and Lampranthus spectabilis increased significantly and had greater than 60% relative coverage with higher hydrophilic polymer concentrations. However, Juniperus chinensis var. sargentii and Euonymus fortunei var. radicans had no significant differences upon change of hydrophilic polymer concentrations. In Carex kujuzana and Carex morrowii 'Aurea variegata', growth decreased with increase of hydrophilic polymer concentrations. 30 days after planting, Juniperus chinensis var. sargentii, Euonymus fortunei var. radicans, Carex kujuzana, and Carex morrowii 'Aurea variegata' died back due to lowest soil thickness (5 cm), but Sedum spurium 'Dragon's blood' and Lampranthus spectabilis had greater than 90% survival.

대스팬 지붕구조물의 등가정적 풍하중 산정에 관한 연구 (A study on the equivalent static wind load estimation of large span roofs)

  • 김대영;김지영;김한영;이명호;김상대
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.245-251
    • /
    • 2004
  • This paper discuss the conditionally sampled actual wind pressure distributions causing peak quasi-static wind loads in the large span roofs using the wind pressures at many locations on dome models measured simultaneously in a wind tunnel. The actual extreme pressure distributions are compared itk load-response-correlation (LRC) method and the quasi-steady pressure distributions. Based on the results, the reason for the discrepancy in the LRC pressure distribution and the actual extreme pressure distribution are discussed. Futhermore, a brief discussion is made of the equivalent static wind load estimation for the large span roofs.

  • PDF

Wind pressure provisions for gable roofs of intermediate roof slope

  • Stathopoulos, Theodore;Wang, Kai;Wu, Hanqing
    • Wind and Structures
    • /
    • 제4권2호
    • /
    • pp.119-130
    • /
    • 2001
  • The paper addresses the suitability of wind pressure coefficients specified in contemporary design standards and codes of practice for gable roofs of intermediate slope (roof angle $10^{\circ}-30^{\circ}$). In a recent research study, a series of low building models with different roof slopes in this intermediate range were tested in a boundary layer wind tunnel under simulated open country terrain conditions. This was different from the original study in the 70's, which produced the current provisions on the basis of a model tested only for a single roof slope (4:12) in this range. The results of the study suggest that a modification to the American wind provisions would be warranted to make them more representative of the true local and area-averaged wind loads imposed on gable roofs of intermediate slope.