• Title/Summary/Keyword: Roof vent

검색결과 33건 처리시간 0.019초

박과작물 재배 단동 비닐하우스의 천장 환기시스템 설치 실태조사 (A field survey on roof ventilation system of single-span plastic greenhouse in cucurbitaceae vegetable cultivation)

  • 여경환;유인호;이한철;정재완;최경이
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.317-323
    • /
    • 2013
  • This research was conducted to obtain the basic information for establishment of standard guidelines in the design and installation of roof ventilation system in single-span plastic greenhouse. To achieve this, the greenhouse structure & characteristics, cultivation status, and ventilation system were investigated for single-span greenhouse with roof ventilation system cultivating the Cucurbitaceae vegetables, watermelon, cucumber, and oriental melon. Most of single-span watermelon greenhouse in Haman and Buyeo area were a hoop-style and the ventilation system in those greenhouses mostly consisted of two different types of 'roof vent (circular or chimney type) + side vent (hole) + fan' and 'roof vent (circular type) + side vent (hole or roll-up type)'. The diameter of circular and chimney-type vent was mostly 60cm and the average number of vents was 10.5 per a bay with vent spacing of average 6.75m. The ratio of roof vent area to floor area and side vent area in the single-span watermelon greenhouse with ventilation fan were 0.46% and 7.6%, respectively. The single-span cucumber greenhouse in Haman and Changnyeong area were a gable roof type, such as even span, half span, three quarter and the 70.6% of total investigated single-span greenhouses was equipped with a roof ventilation fan while 58.8% had a circulation fan inside the greenhouse. The ratios of roof vent area to floor area in the single-span cucumber greenhouse ranged from 0.61 to 0.96% and in the case of the square roof vent, were higher than that of the circular type vent. On average, the roof ventilation fan in single-span cucumber greenhouse was equipped with the power input of 210W and maximum air volume of $85.0m^3/min$, and the number of fans was 9.75 per a bay. The number of roof vent of single-span oriental melon greenhouse with only roll-up type side vent ranged from 8 to 21 (average 14.8), which was higher than that of other Cucurbitaceae vegetables while the vent number of the greenhouse with a roof ventilation fan was average 7 per a bay.

아치형 단동 온실의 지붕 환기 구조 (Roof Ventilation Structure for Single Span Greenhouses of Arch Shape)

  • 남상운
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.267-270
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouse of arch shape. Investigation on the roof ventilation structure for those greenhouses was conducted. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing roof vent and having controlled side vent only. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the roof and side vent.

  • PDF

참외재배 단동 비닐하우스의 환기방법과 설정온도가 병발병도,과실 수량 및 품질에 미치는 영향 (Effects of ventilation systems and set point temperature of single-span plastic greenhouse on disease incidence, fruit quality and yield of oriental melon (Cucumis melo L.))

  • 여경환;유인호;이한철;최경이;이성찬;이중섭
    • 농업과학연구
    • /
    • 제42권4호
    • /
    • pp.325-333
    • /
    • 2015
  • The ventilation systems composed three types of side vent (roll-up) 'SV', side vent+roof vent 'SV+RV', and side vent+roof fan 'SV+RF' with 7.5 m spacing, with specific set point temperatures for ventilation: SV ($35^{\circ}C$ open / $33^{\circ}C$ close), SV+RV or SV+RH ($35^{\circ}C$ open/$33^{\circ}C$ close for root ventilation and $37^{\circ}C$ open / $35^{\circ}C$ close for side vent). In the treatment of SV+RV, although the average daily maximum temperature inside the greenhouse temporarily increased by $38-40^{\circ}C$, thermal stress by high temperature did not occur and the disease incidence (%) of powdery mildew and downy mildew on the oriental melon were 25 - 75% lower than in the conventional SV treatment. In the SV treatment, the disease incidence (%) of powdery mildew and downy mildew were 1.4 - 7.7% and 4.2 - 15.9% for 'Deabakkul', and 20.3 - 22.8% and 2.8 - 11.3%, for 'Ildeungkkul'. The yield for one month was higher in the treatment of SV+RV than those in other treatments, with values of 2,105 kg/10a for 'Deabakkul' and 2,537 kg/10a for 'Ildeungkkul'. The simultaneous treatment with side vent and roof vent resulted in 16.2% higher yield (18.1% higher marketable yield) than that in the SV treatment for 'Deabakkul'.

연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석 (Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent)

  • 박민정;최덕규;손진관;윤성욱;김희태;이승기;강동현
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.36-42
    • /
    • 2020
  • 본 연구에서는 국내에 가장 많이 보급되어 있는 1-2W 모델 연동온실에 대한 온실 규격 및 환기창 형태 실태 조사를 수행하고, 이를 바탕으로 연동온실의 천창 형태에 따른 유동 특성을 분석하기 위해 수치해석을 수행하여 자연환기효과를 분석하고자 하였다. 온실 실태조사 대상농가의 환기창면적 비율은 평균10%로 자연환기를 위한 시설면적 대비 환기창 면적 설계가 부족한 것으로 나타나 환기창 개선이 필요할 것으로 판단된다. 연동 온실의 천창 형태별 자연환기를 해석 및 분석한 결과, 온실 내 작물위치의 온도 분포 및 내외부 온도차는 몽골식 천창 온실에서 가장 낮고 외몽골식 천창 온실에서 가장 높게 나타났으나 추후 풍하중에 의한 구조적인 안전성을 평가해야할 것으로 판단된다.

단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향 (Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon)

  • 여경환;유인호;최경이;이성찬;이재한;박경섭;이중섭
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.334-342
    • /
    • 2016
  • 지붕 환기장치 설치방법의 개선에 의한 작물 재배효과를 검증하고자 농가현장에서 개선 지붕 환기방식과 관행환기방식을 비교, 분석하였다. 개선 지붕 환기방식은 참외재배 단동 플라스틱 온실(폭 5.6m, 길이 108m, 측고 1.1m, 동고 2.2m)에 지붕 환기팬(용량 $38m^3/min$)과 환기통(지름 60cm)을 각각 15m와 6m 간격으로 설치하였고, 대조구로서 관행 지붕 환기방식은 각각 20m와 8m 간격으로 설치하였다. 관행 및 개선 지붕 환기 방식에 따른 생육을 조사한 결과, 관행 환기통과 환기팬 처리에 비해 개선 환기통과 개선 환기팬 처리에서 경경, 엽장, 엽병장, 및 엽폭의 값이 낮게 나타나는 경향을 보였다. 생육기 전반부에 관행 환기통 처리는 환기팬 처리에 비해 절간장이 다소 길게 발달하였는데 이는 착과수가 환기팬 처리에 비해 적었고, 착과수 감소로 인해 동화산물이 잎과 줄기의 신장부로 좀 더 이동된 영향으로 판단되었다. 참외재배 단동 비닐하우스에서 과실 수량을 조사한 결과, 개선 환기팬과 개선 환기통 처리는 관행처리에 비해 과중은 약간 작았지만, 착과수 증가로 인해 전체 수량은 높게 나타났다. 개선 환기팬과 개선 환기통 설치 하우스에서는 관행 지붕 환기 하우스에 비해 상품과율이 높았으며, 10a당 상품수량도 각각 8,391kg, 7,283kg 으로 나타나 관행 지붕 환기에 비해 개선 환기팬 처리는 661kg, 개선 환기통 처리는 487kg 더 증가하였다. 개선 환기팬 처리는 고온기에 암꽃수와 착과수가 가장 많았고, 낙과수는 가장 낮게 나타났으며, 관행의 환기통 처리에 비해 과실의 크기는 작았다. 시기별 환기방식에 따른 참외 과실의 품질을 조사한 결과, 관행 환기통 환기에서 과중, 과경, 과폭, 및 과육두께가 가장 높게 나타났으나, 과폭, 과육두께에 있어서 통계적인 유의차는 나타나지 않았다.

초고층공동주택 국소배기용 입상덕트의 배기성능평가에 관한 연구 (Study on the Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;이태규;안정헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.889-894
    • /
    • 2008
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

  • PDF

플라스틱 단동온실의 천창 종류에 따른 자연환기 효과 (Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse)

  • 라쉬드아드난;이종원;김현태;이현우
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.225-233
    • /
    • 2019
  • 여름철에 자연환기는 온실의 온도를 낮추는데 중요한 역할을 한다. 온실의 형태, 환기창 종류, 환기창의 위치 등은 자연환기 성능에 큰 영향을 미친다. 본 연구에서는 전산유체역학(CFD)을 이용하여 다양한 천창구조에 대하여 측창에 따른 부력환기 효과를 비교분석 하였다. Boussinnesq 가정을 사용하여 전체 계산영역에 대한 부력효과를 시뮬레이션 하였다. 또한 RNG $K-{\varepsilon}$ 난류모델을 사용하였다. 일사량 효과를 시뮬레이션 하기 위해 Solar ray tracing과 함께 Discrete originates (DO) radiation 모델을 사용하였다. 실험온실 내부의 온도를 측정하여 CFD모델을 검증하였으며, 실험값과 계산값이 잘 일치하는 것으로 나타났다. 7가지의 천창구조에 대하여 온실의 내외부 온도차이와 환기횟수를 비교하였다. 내외부온도의 차이는 $3.2{\sim}9.6^{\circ}C$ 범위로 나타났고, 환기횟수는 $0.33{\sim}0.49min^{-1}$ 범위로 나타났다. 고깔형 천창구조 온실의 경우 내외부 온도차이가 $3.2^{\circ}C$로 가장 낮았고 환기횟수도 $0.49min^{-1}$로 가장 높게 나타나 환기효과가 가장 우수한 것으로 나타났다.

터널화재시 자연환기에 의한 연기거동에 관한 실험적 연구 (An Experimental Study of Smoke Movement in Tunnel Fires with Natural Ventilation)

  • 김충익;유홍선;이성룡;박현태
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.247-253
    • /
    • 2002
  • In this study, reduced-scale experiments were conducted to analyze smoke movement in tunnel fire with roof vent. The 1/20 scale experiments were carried out under the Froude scaling using gasoline pool fire ranging from 7.3 to 15.4 cm in diameter with total heat release rate from 1.0 to 8.46kw. In case of 1 m high vent, smoke front reached to the tunnel exit at about 16 sec delayed with ventilation. The delay time grew longer with the vent height. The temperature after the vent was lower than that without the vent. The exit temperature declined maximum of $20^{\circ}C$ after passing the vent. It was confirmed that the thickness of smoke layer was maintained uniformly under the 25% height of the tunnel through the visualized smoke now by a laser sheet and the digital camcorder.

아치형 단동온실의 지붕환기구조 및 천창효과 (Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape)

  • 남상운
    • 농업과학연구
    • /
    • 제28권2호
    • /
    • pp.99-107
    • /
    • 2001
  • 온실재배에 있어서 가장 경제적인 환경조절방법은 자연환기에 의한 것이므로 온실의 자연환기 성능을 극대화하는 것은 매우 중요하다. 온실의 자연환기 성능을 극대화하기 위해서는 지붕환기창의 설치가 중요한데, 아치형 단동 온실의 경우에는 천창을 설치하기 어려운 구조로 되어 있어서 대부분의 농가가 측창만 설치하여 운영하고 있다. 본 연구에서는 아치형 단동 온실의 지붕에 환기창 설치를 장려하기 위한 일환으로 사례조사와 효과분석을 실시하였다. 아치형 단동 온실의 지붕환기구조 실태조사 결과 폭 5~8m의 소형 온실에서는 플라스틱으로 제작된 원형 및 굴뚝형 환기창을, 폭 12~18m의 대형온실에서는 철재 파이프를 덧붙인 양권취식을 많이 사용하고 있었다. 지붕환기창 설치 온실과 관행의 권취식 측창만 설치된 온실에 대한 대조 실험 결과 비록 적은 면적의 지붕환기창을 설치하였지만 온도하강 $1^{\circ}C$ 이상의 천창 환기 효과가 있었으며, 지붕환기를 실시함으로써 온도분포를 보다 균일하게 할 수 있는 것으로 나타났다. 지붕환기창을 설치함으로서 얻을 수 있는 온도상승 억제효과는 일사량과 풍속조건에 따라 뚜렷한 차이를 보이며, 풍속이 낮은 경우에 효과가 커지는 것을 확인할 수 있었다. 환기창의 개폐순서에 따른 전체적인 온도 하강의 차이는 없으나, 환기로 온도를 제어하는 경우에는 실내온도가 설정온도보다 높을 때는 천창을 열은 후 측창을 열고, 반대의 경우에는 측창을 닫은 후 천창을 닫는 것이 바람직한 것으로 판단되었다.

  • PDF

CFD 검증을 위한 풍동 및 PIV를 이용한 자연환기식 온실 내부 공기유동 분석 (Analysis on Internal Airflow of a Naturally Ventilated Greenhouse using Wind Tunnel and PIV for CFD Validation)

  • 하정수;이인복;권경석;하태환
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.391-400
    • /
    • 2014
  • The number of large scale greenhouses has recently been increasing to cope with mass consumption of agricultural product. Korean government announced a new development plan for constructing greenhouse complex in reclaimed lands for the purpose of improvement in exports and activation of domestic market of agricultural product. Wind environment in the reclaimed land is totally different from that of inland area, and it can give a strong influence on ventilation performance of naturally ventilated greenhouse facilities. In this study, internal airflow analysis of naturally ventilated greenhouse built on a reclaimed land was conducted using wind tunnel and PIV for validation research. Later, the PIV measured results will be used to improve the accuracy of 3 dimensional CFD simulation in the future. Wind profile at a reclaimed land was produced using ESDU program and it was applied to the wind tunnel. The calculated error was only 5% and 0.96 of correlation coefficient, implying that the computed profiles were designed properly. From the measured results, when external wind speed changed from $1m{\cdot}s^{-1}$ to $1.5m{\cdot}s^{-1}$, air velocities inside the greenhouse which PIV measured were also increased proportionately in case of both side vent open and side-roof vent open. Considering reduced ratio of air velocity inside the greenhouse, it was measured a minimum of 40% in case of side vent and 30% in case of side-roof vent compared with external wind speed from each vent type. From the quantitative and qualitative PIV analysis, the PIV measured results indicated that there were well ventilated and stagnant areas in the greenhouse according to external wind condition as well as ventilation design.