• 제목/요약/키워드: Roof fan

검색결과 33건 처리시간 0.025초

Effects of Cooling and Exogenous Bovine Somatotropin on Hematological and Biochemical Parameters at Different Stages of Lactation of Crossbred Holstein Friesian Cow in the Tropics

  • Chaiyabutr, N.;Boonsanit, D.;Chanpongsang, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권2호
    • /
    • pp.230-238
    • /
    • 2011
  • Effects of cooling and supplemental recombinant bovine somatotropin (rbST) on hemato-biochemical characteristics were studied at different stages of lactation of crossbred Holstein Friesian cows in a tropical environment. Ten primiparous cows were divided into two groups of five animals each. The first group was housed as the non-cooled animals in an open-sided barn with a tiled roof in a normal shaded house (NS), while the second group was housed as cooled cows in an open-sided barn with a tiled roof under misty fan cooling (MFC). Three injections with rbST (500 mg per dose) at each stage of lactation (early, mid and late lactation) significantly increased total milk yield as compared with pretreatment in both cooled and non-cooled cows. Milk fat was significantly increased, while total solids, solid not fat, milk protein and lactose were not affected by the rbST treatment. Hematological parameters, plasma proteins, albumin, glucose, triglyceride, cholesterol, creatinine, alkaline phosphatase (ALP), plasma inorganic phosphate and the activities of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) were not affected by supplemental rbST in cooled and non-cooled cows. Supplementation of rbST caused a significant decrease in plasma urea concentration, while plasma FFA concentrations significantly increased in both cooled and non-cooled cows. The results of the present study suggest that exogenous rbST is efficacious in increasing milk yield without adverse effects on lactating crossbred Holstein cows in a tropical environment.

한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발 (Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse)

  • 이현우;심상연;남효석;남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.185-191
    • /
    • 2009
  • 본 연구는 우리나라의 기상환경에 적합한 한국형 공기주입 이중피복 플라스틱 온실을 설계하는데 필요한 기초자료를 제공하기 위하여 실험용 공기주입 이중피복 플라스틱 온실을 제작하여 작동실험을 실시하고 온실내부의 환경변화를 분석하였다. 온실의 피복재를 설치할 때 시공기술이 부족하여 밀폐도가 많이 떨어지는 것으로 나타났기 때문에 이중피복 공기충의 정압을 적절하게 유지하기 위해서는 높은 밀폐도를 유지할 수 있는 피복재 설치기술과 관련 자재의 개발이 요구되었다. 관행의 이중피복온실보다 공기주입 이중피복온실이 단열효과가 더 우수하였으며, 특히 아치형 지붕형태의 공기주입 이중피복온실이 복숭아 형태의 관행온실에 비해 $2^{\circ}C$ 정도 높아 보온효과가 상당히 우수한 것으로 나타났다. 시공성이 우수하고 밀폐도를 높일 수 있는 피복방식은 온실위에 피복재를 덮은 상태에서 여유길이를 두지 않고 자연스럽게 고정시키는 것이 가장 바람직하였다. 다른 조건들이 동일한 공기주입 이중피복 단동온실의 경우 복숭아형 지붕온실에 비해 아치형 지붕온실에서 광투과율이 더 높은 것으로 나타났다. 3연 동 온실의 경우에는 관행 이중피복온실에 비해 공기주입 이중피복온실이 광투과율이 더 높은 것으로 나타났으며, 이는 주로 골조율과 이중피복재간의 간격 때문인 것으로 판단되었고, 이에 대한 자세한 원인은 앞으로 추가적인 실험을 통해 검증할 예정이다. 결로의 발생현상을 가시적으로 비교한 결과 관행온실에서 더 많은 결로가 발생함을 확인할 수 있었다 그러나 정량적인 비교를 위해서는 장기간의 관측과 이론적인 분석이 필요할 것으로 판단되며, 향후 더 자세한 실험을 통해 규명할 예정이다.

볼프스부르크 문화센터의 건축 특성과 의미에 관한 연구 (A Study on the Architectural Characteristics and Meaning of Wolfsburg Cultural Center)

  • 정태용
    • 한국실내디자인학회논문집
    • /
    • 제20권2호
    • /
    • pp.47-54
    • /
    • 2011
  • In Alvar Aalto's designs, important factors of complex building designs including Wolfsburg cultural center are that they insinuate how to develop each architectural type and how to combine them in a building. The humane and physical background studies, and wholistic and systematic approaches are adopted to fulfill research purposes. Comparison with other buildings are necessary to reveal true meaning of this building. The result of analysis show characteristics of Wolfsburg cultural center as follows; hybrid composition of mass and elevation, spatial effect using level difference and light, massing variation of roof, and creating space for various activities. Wolfsburg cultural center designed in late 1950s has greatly affected Aalto's later works through various architectural experiments because it is the first cultural complex project that combined various architectural types. Especially library in the cultural center has shown transitional characteristics to famous fan-type libraries of 1960s while maintained features about Viipuri library. Wolfsburg cultural center act as an another type which present new principles of clustering, massing and exterior design. Its true meaning lies in forming a humanizing place beyond spatial configuration.

실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석 (Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments)

  • 한화택;신철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF

화력발전소 터빈 본관의 환풍기 위치 및 용량 최적화에 관한 연구 (A Study on the Optimization of Ventilation Fan Position and Flow Rate for a Turbine Building of a Power Plant)

  • 김태권;하지수;박찬혁
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.86-93
    • /
    • 2016
  • 화력발전소 터빈 본관 내부는 고온의 스팀 배관, 탈기기, 스팀 저장 탱크, 수증기 차단 밸브 등의 존재로 터빈 본관 작업 공간의 공기가 고온으로 올라가서 작업자가 장시간 작업하기 곤란한 경우가 발생한다. 터빈 빌딩 작업공간의 공기를 냉각하기 위해 터빈 빌딩 창문을 개방하여 외부의 찬 공기로 냉각하고 상부에 환풍기를 설치하여 외부로 배출한다. 이렇게 한 경우에도 국부적으로 고온의 영역이 존재하여 작업 공간의 냉각을 위한 추가적인 환풍기 설치가 필요하고, 이 경우 환풍기의 위치와 유량에 대한 최적화가 필요하다. 본 연구는 여러 가지 경우의 열 유동 해석을 통해 쾌적한 작업환경을 위한 추가적인 환풍기의 위치와 용량을 최적화한 방안을 제시 하는 것을 목적으로 하였다. 본 연구를 통해 기존 환풍기 위치와 용량을 기준으로 터빈 본관 내부의 고온 영역인 탈기기 영역근처의 열원을 배출하는 환풍기를 추가로 설치하는 것이 전체온도를 $3.0^{\circ}C$, 가장 고온의 영역인 탈기기영역의 온도를 $4.2^{\circ}C$ 저감할 수 있었다.

환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석 (Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses)

  • 허종철;임종환;서효덕;최동호
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.27-39
    • /
    • 2000
  • 본 실험에 앞서, 하우스 4개동에 대한 대칭성 실험을 실시하였으나, 각 하우스간에는 최대1$^{\circ}C$이내의 작은 온도차만이 계측되었다. 하우스 개폐장치 조작 불능시를 가정하여 천.측창을 인위적으로 폐쇄한 경우, 하우스 내 온도는 외 기온보다 약 16$^{\circ}C$ 높은, 즉 사실상 작물이 생육 할 수 없는 고온상태를 나타내었다. 천.측창을 개방한 상태에서는 환기팬을 추가로 가동시키더라도 이에 따른 추가적인 실온저하는 관찰되지 않았다. 비교적 분무 입경이 큰 스프링클러에 의한 환수시의 냉각효과를 검토한 결과, 하우스 내 온도는 스프링클러 작동과 동시에 급속히 하강함으로서, 관수는 하우스 실온저하에 크게 기여하고 있음이 확인되었다. 스프링클러 관수시와 비관수시로 구분하여 하우스 내 열환경을 비교한 결과, 관수시와 비관수시 모두 하우스의 천.측창을 개방하여 외기를 도입한 경우가 하우스 실온 저하에 효과적으로 작용한 것으로 조사되었다. 하우스 내 작물 체감온도에 근사한 온도지표인 실내 흑구온도는 비관수시의 경우 실내 공기온도보다 현저히 놀게 나타났으나, 관수시의 온도는 실내 공기온도에 근접한 온도를 나타내었다. 비관수시 천.측창을 개방한 경우 하우스 내 온도분포는 연직방향, 수평방향 모두 1$^{\circ}C$ 정도의 극히 작은 온도차만이 계측됨으로서, 하우스 내는 극히 균일한 온도를 유지하고 있음이 확인되었다

  • PDF

Numerical simulation on mining effect influenced by a normal fault and its induced effect on rock burst

  • Jiang, Jin-Quan;Wang, Pu;Jiang, Li-Shuai;Zheng, Peng-Qiang;Feng, Fan
    • Geomechanics and Engineering
    • /
    • 제14권4호
    • /
    • pp.337-344
    • /
    • 2018
  • The study of the mining effect influenced by a normal fault has great significance concerning the prediction and prevention of fault rock burst. According to the occurrence condition of a normal fault, the stress evolution of the working face and fault plane, the movement characteristics of overlying strata, and the law of fault slipping when the working face advances from footwall to hanging wall are studied utilizing UDEC numerical simulation. Then the inducing-mechanism of fault rock burst is revealed. Results show that in pre-mining, the in situ stress distribution of two fault walls in the fault-affected zone is notably different. When the working face mines in the footwall, the abutment stress distributes in a "double peak" pattern. The ratio of shear stress to normal stress and the fault slipping have the obvious spatial and temporal characteristics because they vary gradually from the higher layer to the lower one orderly. The variation of roof subsidence is in S-shape which includes slow deformation, violent slipping, deformation induced by the hanging wall strata rotation, and movement stability. The simulation results are verified via several engineering cases of fault rock burst. Moreover, it can provide a reference for prevention and control of rock burst in a fault-affected zone under similar conditions.

듀플렉스트러스트시스템의이해 - 옥천대태백산지역영월트러스트시스템에의 적용 (Understanding of the Duplex Thrust System - Application to the Yeongwol Thrust System, Taebaeksan Zone, Okcheon Belt)

  • 장이랑
    • 자원환경지질
    • /
    • 제52권5호
    • /
    • pp.395-407
    • /
    • 2019
  • 듀플렉스 시스템(duplex system)은 조산대의 진화에서 슬립을 전달하는 중요한 매커니즘 가운데 하나로 고려되어 왔다. 이들은 일반적으로 습곡-단층대의 후방지(hinterland)에 발달하며, 조산대를 이루는 총 수축의 많은 부분을 수용한다. 그러므로 듀플렉스의 구조기하학 및 키네마틱 진화에 대해 이해하는 것은 전체 조산대의 진화를 평가하는데 있어 중요한 정보를 제공할 수 있다. 듀플렉스는 지질도 상에서 트러스트들에 의한 폐곡선 형태의 단층 자취에 의해 인지되는데, 이들은 인편팬(imbricate fan) 시스템의 경우보다 높은 연결성을 보인다. 원래의 정의에 따르면, 듀플렉스는 바닥트러스트(floor thrust)와 지붕트러스트(roof thrust) 및 이들 사이의 인편상 트러스트(imbricate thrust)들에 의해 사방이 둘러싸인 포로암(horse)들로 구성된다. 이들은 광역적인 지층-평행 수축(layer-parallel shortening)을 수용하며, 바닥트러스트로부터 지붕트러스트로 단층을 따라 발생하는 슬립을 전달하는 역할을 한다. 그러나 인편상 단층이 바닥 및 지붕 트러스트 사이에서 발생하는 지층-평행 수축이나 변위 전달의 유일한 수단은 아니다. 지층-평행 수축 벽개(LPS cleavage)와 분리단층습곡(detachement fold) 또한 동일한 역할을 수행할 수 있다. 이러한 견지에서, 듀플렉스는 1) 단층 듀플렉스, 2) 벽개 듀플렉스, 3) 습곡 듀플렉스의 3가지 유형으로 나눌 수 있다. 단층 듀플렉스는 다시 Boyer-type 듀플렉스와 커넥팅-스플레이(connecting splay) 듀플렉스로 세분된다. 전자는 1980년대에 트러스트시스템의 개념을 적용하여 최초로 정의된 듀플렉스 형태이고, 후자는 듀플렉스 형성 시 포로암들의 발달 순서에 있어 전자의 듀플렉스와 차이를 가진다. 이들 단층 듀플렉스 유형은 전 세계적으로 주요 습곡-단층대의 구조진화 연구에 널리 적용되어왔다. 반면에, 벽개 듀플렉스 및 습곡 듀플렉스는 몇몇의 노두에서 선택적으로 보고된 내용에 기반하여 최근에 새롭게 제안된 듀플렉스 유형이다. 한반도 옥천대 내 태백산 분지 서쪽의 영월지역은 높은 연결성을 보이는 트러스트들에 의한 폐곡선 형태의 단층 자취가 잘 보존되어 있는 곳으로, 국내에서 습곡-단층대 내에서 트러스트시스템에 듀플렉스 모델을 적용시켜 볼 수 있는 최적의 연구지역이다. 이 지역 지질구조에 대한 구조기하학 및 키네마틱스 해석을 바탕으로 영월트러스트시스템은 'Boyer-type 후방지로 경사진 듀플렉스(hinterland-dipping duplex)' 및 '주요 인편상 트러스트와 커넥팅-스플레이로 구성된 듀플렉스(connecting splay duplex)'의 두 가지 모델로 해석된 바 있다. 영월지역 내에 고각의 지층과 트러스트들이 반복되고, 듀플렉스를 구성하는 각 포로암 내에 서로 다른 층서 패키지가 포함되는 등 여러 간접적인 증거들이 후자의 모델을 지지함에도 불구하고, 직접적인 야외 증거나 단층 활동에 대한 시간 정보 등이 부족하기 때문에 두 모델 중 어느 것이 더 적합한지를 판단하기에는 어려움이 따른다. 게다가 최근 새롭게 제안된 습곡 듀플렉스와 벽개 듀플렉스 모델 또한 영월트러스트시스템의 구조 해석에 적용될 수 있는 가능성이 있기 때문에, 향후 영월 및 주변 지역에 대한 추가 야외 지질조사 및 다양한 지구연대학적 연구가 추가적으로 요구된다. 이러한 후속 연구들의 결과는 옥천대의 형성 및 구조진화와 관련된 그간의 난제를 풀 수 있는 중요한 정보를 제공할 수 있을 것으로 기대한다.

난황유와 공기순환팬의 상추 흰가루병 방제효과 및 생산에 미치는 영향 (Effect of COY (Cooking Oil and Yolk mixture) and ACF (Air-circulation Fan) on Control of Powdery Mildew and Production of Organic Lettuce)

  • 지형진;류경열;박종호;최두회;류갑희;류재기;신순선
    • 식물병연구
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2008
  • Podosphaera fusca에 의한 상추 흰가루병은 최근에 보고된 새로운 병해이나 심하게 발생될 경우에는 수량을 50% 이상 감소시켜 유기농 상추재배에 큰 위협요인 되고 있다. 본 연구에서는 비닐하우스 내부에 소형의 공기순환팬을 6 m 간격으로 설치하여 상추 주변의 기상환경을 개선한 결과 수량 57% 증가와 정식묘 고사율 71.4% 감소 효과를 얻었다. 공기순환팬을 설치한 하우스에서 식용유를 계란노른자로 유화시킨 난황유 0.3% 용액을 처리한 경우에는 농가 관행재배 하우스에 비해 묘 고사율은 $89.3{\sim}92.9%$ 감소되었고 상추 흰가루병 방제효과는 89.6-96.3%로 매우 높게 나타나 살균제(azoxystrobin)와 대등하였다. 난황유 처리구별로 상추 수량은 $23.3{\sim}26.5\;kg$으로 대조 하우스의 11.86 kg과 비교할 때 약 2배 정도 높았고 상추 잎의 경도는 다소 낮고 엽록소 함량은 높아지는 등 상추 품질을 개선하는 효과도 나타났다. 본 연구 결과를 볼 때 채종유를 계란노른자로 유화시켜 만든 난황유는 상추 흰가루병 방제효과가 매우 높고 유기농 상추 생산에 유용하게 활용할 수 있을 것으로 기대되는데 공기순환팬을 설치하여 재배환경을 개선하면 상승효과를 얻을 수 있는 것으로 나타났다.

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF